Service
Menu item
Setting
Description
Standard values
Sensor type
NI120/PT100/NTC/FeCu
Selection of the sensor type
of the channels
NI120
Max. temperature
[°C]
0-195 °C
(0-250 °C
high temperature unit)
Max. permissible heating
temperature
195 °C
Max. over-
temperature [°C]
0-210 °C
(0-270 °C
high temperature unit)
highest permissible
temperature before the
alarm sounds
210 °C
Warning temperature
[°C]
-8 / +10
Deviation from the target
value
10
Temperature of the
system
°C / °F
Setting Celsius or
Fahrenheit
°C
Start hose [%]
0-100
Engagement of the hose
heater to X% of the tank
temperature
80
Start head [%]
0-100
Engagement of the head
heater to X% of the hose
temperature
80
Maintenance date
xx:xx:xxxx
next maintenance
C 0,5 year
Maintenance time
0-4000
Operating hour meter until
the next maintenance
2000
Alarm memory
0-99
99 Alarm messages
Operating times
Tank - Hoses - Heads
Operating hour meter of the
connected channels
PW7873
CPU Temperature
[°C]
0-65
current CPU temperature
30 °C
Software version
1.0
Software Update PW2401
Temperature
difference
-30 / +30
difference between tank
and manifold/ pump
*1
0 °C
Password Temp.
Parameter
1507
Protects the temperature
settings
Off
Password Service
7873
Protects the service
settings
On
Alarm/ Ready display
On / Off
Turning off the entire
screen display
Green
/
Red
On
Activate format
On / Off
activate/deactivate the
format setting
On
Quantity channel
boards
1-4
activate/deactivate the
channel boards
1
Tank 2
Heating lower limit
-10 - (-99)
Setting the negative
temperature difference for
T2 without losing the Ready
signal
*2
-10
Tank 2
Heating upper limit
8
– 99
Setting the positive
temperature difference for
T2 without losing the Ready
signal
*2
8