background image

IRT803

OFF

ZERO

ZERO

FUSED

V

Ω

COM

INSULATION

V

1000V

500V

250V

100V

INSULATION TESTER

600V

CAT IV 600V

CAT III 1000V

COMPARE

LOCK

PI/DAR

TEST

SELECT

HOLD

0

0.1 M

1 M

10 M

100 M

1 G

20 G

Apo

V

DC

INSTRUCTION MANUAL

ENGLISH

IRT803

1000V AC/DC Digital Insulation 

Resistance Tester

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Summary of Contents for IRT803

Page 1: ...TESTER 600V CAT IV 600V CAT III 1000V COMPARE LOCK PI DAR TEST SELECT HOLD 0 0 1M 1M 10M 100M 1G 20G Apo VDC INSTRUCTION MANUAL ENGLISH IRT803 1000V AC DC Digital Insulation Resistance Tester www Glo...

Page 2: ...20k 8 Continuity 9 Insulation Resistance 1000V 500V 250V 100V 10 Polarization Index Dielectric Absorption Ratio 1000V 500V 250V 100V 11 Compare Function 12 Test Lead Notes 12 Testing the Fuse 13 Test...

Page 3: ...V 600V CATIII 1000V IP42 RoHS 6 Drop Protection IEC EN 61010 1 2010 Battery Type AA 4 Test Leads Silicone test leads w alligator clips red and black ATL57 Remote Probe Accuracy of reading of least sig...

Page 4: ...ment PPE to prevent shock and arc blast injury where hazardous live conductors are exposed Always turn off power to a circuit or assembly under test before cutting unsoldering or breaking the current...

Page 5: ...r Than PI DAR ZERO 30 Segment Bargraph Ground Measurement Category Short Circuit typical kAa Location in the building installation II 10 Circuits connected to mains socket outlets and similar points i...

Page 6: ...esistance test and PI PAR test Also used for testing the fuse H Function Dial Turns on meter and is used to select the function I Category Max Indicator Maximum CAT Rating for input jacks Use CATIII t...

Page 7: ...ection AC 1000V rms or DC O Kick Stand For easy viewing of screen when testing P Battery and Fuse Cover under protective rubber boot Q Serial Number under kick stand IRT803 OFF ZERO ZERO FUSED V COM I...

Page 8: ...t test Test stops when the button is released Features TEST SELECT LOCK NOTE When the resistance is higher than the maximum display range the tester displays the symbol and the maximum resistance for...

Page 9: ...OLD Apo V Continuity Features HOLD WARNING Do not measure resistance continuity on a live circuit Beeper sounds constant as long as circuit is complete Beeper sounds when a short 40 is detected RANGE...

Page 10: ...GE RESOLUTION TEST CURRENT ACCURACY 100V 0 to 20 0 01 to 20 00M 0 01M 1mA 100k 3 5dgts 20 0 to 100 0M 0 1M 250V 0 to 20 0 01 to 20 00M 0 01M 1mA 250k 1 5 5dgts 20 0 to 200 0M 0 1M 500V 0 to 20 0 01 to...

Page 11: ...OCK PI DAR TEST Because of the time required for the PI and DAR tests alligator clips are recommended Use rotary selector dial to select desired test voltage The display will show until test starts Th...

Page 12: ...Lead Notes CATIV 600V Measurement Locations Ensure the test lead shield is pressed firmly in place Failure to use the CAT IV shield increases arc flash risk CAT II Measurement Locations CAT IV shield...

Page 13: ...ly test the batteries Turn the rotary selector dial to the Battery Voltage position with no test leads connected Press the Select button to start the battery test The battery voltage is displayed for...

Page 14: ...ve rubber boot Remove protective rubber boot Remove battery cover Replace the fuse F 440mA 1000V 1R 10kA Replace the battery cover Replace the protective rubber boot Removed protective rubber boot Rem...

Page 15: ...nit will be repaired or replaced at UEi s option This warranty covers normal use and does not cover damage which occurs in shipment or failure which results from alteration tampering accident misuse a...