UEi ATTPC3 Instruction Manual Download Page 1

Hi-NCV-Lo

MFD

°F 

°C

µA

 CAT Ill

 600V                        400A

MAX/MIN

HOLD

Hz / Duty

SELECT

TEMP

DISCONNECT

30V MAX

TEST LEADS

True RMS

DL389B

MAX

CATll1000V

CATIII600V

INSTRUCTION MANUAL

ENGLISH

DL389B

TRMS Dual Display Clamp Meter

1000V

CAT II

600V

CAT III

www.

.com

[email protected]

1.800.561.8187

Summary of Contents for ATTPC3

Page 1: ...A MAX MIN HOLD Hz Duty SELECT TEMP DISCONNECT 30V MAX TEST LEADS True RMS DL389B MAX CATll1000V CATIII600V INSTRUCTION MANUAL ENGLISH DL389B TRMS Dual Display Clamp Meter 1000V CAT II 600V CAT III www com information itm com 1 800 561 8187 ...

Page 2: ... OPERATING INSTRUCTIONS AC DC Voltage 750Vac 1000Vdc 8 Resistance 9 Continuity 9 Diode 10 AC Amp 400A 11 Capacitance MFD 11 AC DC Low Amps 12 Non Contact Voltage Hi Lo 13 Temperature C F 13 Frequency Hz Duty Cycle Measurements 14 Test Lead Notes 15 Battery Replacement 15 WARRANTY 16 DISPOSAL 16 CLEANING 16 STORAGE 16 www com information itm com 1 800 561 8187 ...

Page 3: ...mp GENERAL SPECIFICATIONS Operating Temperature 32 to 104 F Storage Temperature 4 to 140 F Operating Humidity 80 Max Operating Altitude 6 562 ft 2000m Pollution Degree 2 Display 4 000 Count Back Light YES Refresh Rate 3 per Sec Over range OL is displayed Dimensions 8 70 in x 3 23 in x 1 50 in Item Weight 11 1 oz Calibration Recommended Annually CAT Rating CATIII 600V CATll 1000V Certifications CAT...

Page 4: ...Always adhere to national and local safety codes Use proper personal protective equipment PPE to prevent shock and arc blast injury where hazardous live conductors are exposed Always turn off power to a circuit or assembly under test before cutting unsoldering or breaking the current path Even small amounts of current can be dangerous Always disconnect the live test lead before disconnecting the c...

Page 5: ...nheit Degrees Celsius Continuity Mega X106 or 1 000 000 Milli X10 3 or 0 001 Kilo X103 or 1 000 Nano X10 9 or 0 000000001 Micro X10 6 or 0 000001 Warning or Caution Ground Dangerous Levels Double Insulation Protection To Class II Safe for Disconnect from Live Conductors CATEGORY RATING DEFINITIONS Measurement Category Short Circuit typical kAa Location in the building installation II 10 Circuits c...

Page 6: ...or objects to become pinched in the base as the jaws close I Hi NCV Lo Alert Light Indicates voltage when in NCV mode J Hi NCV Lo Button 24V to 600V range Press and hold for NCV detection K Range Button Press repeatedly to cycle through manual ranges Press and hold to return to auto ranging mode AT is displayed on LCD only during auto ranging mode Note Select range prior to MAX MIN for best result...

Page 7: ...e limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in any particular installation If thi...

Page 8: ...mV 2 0 5 dgts 750V RMS 4V 1mV 40V 10mV 400V 100mV 750V 1 0V 45Hz to 1kHz True RMS crest factor 3 1 DC Volts Range Resolution Accuracy Overload Protection 400mV 0 1mV 0 5 4 dgts 1000V RMS 4V 1mV 40V 10mV 400V 0 1V 1000V 1V 0 8 10 dgts Hi NCV Lo MFD F C µA CAT Ill 600V 400A MAX MIN HOLD Hz Duty SELECT TEMP DISCONNECT 30V MAX TEST LEADS True RMS DL389B MAX CATll1000V CATIII600V V Features RANGE AC DC...

Page 9: ... MAX TEST LEADS True RMS DL389B MAX CATll1000V CATIII600V Hi NCV Lo MFD F C µA CAT Ill 600V 400A MAX MIN HOLD Hz Duty SELECT TEMP DISCONNECT 30V MAX TEST LEADS True RMS DL389B MAX CATll1000V CATIII600V Buzzer sounds at less than 50Ω WARNING Do not measure resistance on a live circuit Open Circuit Voltage Overload Protection 0 44V 600V RMS Threshold approx 50Ω Default Press x1 Resistance 40MΩ Conti...

Page 10: ...2 0V 1 6V DC 0 25mA 600V RMS Hi NCV Lo MFD F C µA CAT Ill 600V 400A MAX MIN HOLD Hz Duty SELECT TEMP DISCONNECT 30V MAX TEST LEADS True RMS DL389B MAX CATll1000V CATIII600V Diode GOOD DIODE BAD DIODE Forward Bias displays approx voltage drop Reverse Bias Displays OL or Open Diode Displays OL Both directions Features A www com information itm com 1 800 561 8187 ...

Page 11: ...st accuracy Opposing currents cancel use line splitter when necessary Keep hands below guard when measuring high current levels Do not attempt to measure more than 400A AC Range Resolution Accuracy Overload Protection 40A 0 01A 2 9 15 dgts 600V RMS 400A 0 1A 1 9 8 dgts 45Hz to 400Hz True RMS crest factor 3 1 Features Single Conductor Only Hi NCV Lo MFD F C µA CAT Ill 600V 400A MAX MIN HOLD Hz Duty...

Page 12: ... Input Range Resolution Accuracy Overload Protection 400µA 0 01µA 2 0 5 dgts 2000µA 600V RMS 2000µA 0 1µA 1 5 5 dgts 45Hz to 400Hz True RMS crest factor 3 1 AC DC Low Amps 2000µA Hi NCV Lo MFD F C µA CAT Ill 600V 400A MAX MIN HOLD Hz Duty SELECT TEMP DISCONNECT 30V MAX TEST LEADS True RMS DL389B MAX CATll1000V CATIII600V Default Press x1 µA Features RANGE µA www com information itm com 1 800 561 8...

Page 13: ...or from an external interference such as motors flashlights etc Non Contact Voltage Hi Lo NCV NCV Sensor located in tip Temperature F C Hi NCV Lo MFD F C µA CAT Ill 600V 400A MAX MIN HOLD Hz Duty SELECT TEMP DISCONNECT 30V MAX TEST LEADS True RMS DL389B MAX CATll1000V CATIII600V Default Press x1 Features WARNING Disconnect test lead probes from voltage source and meter Press Select button to chang...

Page 14: ...z DC V offset should be zero Sensitivity 10 of each AC volt range except 4V 20 range only Duty Cycle Range Accuracy Overload Protection 1 0 to 99 0 0 2 per kHz 0 1 5 dgts 600V RMS 0 5Hz to 100KHz pulswidth 2µ sec Frequency Hz Duty Cycle Measurements Hi NCV Lo MFD F C µA CAT Ill 600V 400A MAX MIN HOLD Hz Duty SELECT TEMP DISCONNECT 30V MAX TEST LEADS True RMS DL389B MAX CATll1000V CATIII600V Defaul...

Page 15: ... to lose the shields WARNING Test lead category protections apply only to test leads and should not be confused with the meter s specific CAT rating Observe the maximum category protection indicated on the meter the test leads are plugged into 4mm 18mm 4mm 18mm Battery Replacement When the batteries are too low for safe operation the Low Battery indicator will display Loosen screw Remove battery c...

Page 16: ...c loss A purchase receipt or other proof of original purchase date will be required before warranty repairs will be rendered Instruments out of warranty will be repaired when repairable for a service charge For more information on warranty and service contact This warranty gives you specific legal rights You may also have other rights which vary from state to state DISPOSAL CAUTION This symbol ind...