background image

ON

OFF

POWER

WZ-600

PAGING SELECTOR

MUSIC

MICRO

REC

STOP

PLAY

ACTIVE

MIC

ZONE5

ZONE6

ZONE1

ZONE2

ZONE3

ZONE4

TUNER

CD

TAPE

OUTPUT LEVEL

MASTER

BASS

TREBLE

MESSAGE RECORDER

5

4

3

2

1

0

6

7

8

9

10

0

-1

-2

-3

-4

-5

+1

+2

+3

+4

+5

0

-1

-2

-3

-4

-5

+1

+2

+3

+4

+5

5

4

3

2

1

0

6

7

8

9

10

5

4

3

2

1

0

6

7

8

9

10

TAPE

CD

TUNER

ZONE 1 OUT

OPEN RELE IN

IN COM ZONE

ZONE 2 OUT

ZONE 3 OUT

ZONE 4OUT

ZONE 5 OUT

ZONE 6 OUT

RELE ZONE CONSOL OUT

1

2

3

4

5

6

MIX MUSIIC

PAGE OUT

MUSIC OUT

COM N01 N02

PAGE OUT

PLAY MESSAGE

MESSAGE

2

3

1 OFF

CONTINUOS

NORMAL

MIC

MESSAGE

MESSAGE

REG

1 TIME

ALARM

PHANTOM

PRIORITY

MICRO

CONSOL

CONSOL
VOLUME

GAIN

GAIN

VOL.
REG

VOL.

PLAY

VOLUME

CHIME

230VAC  50Hz

T1AL 250V

RIESGO DE CHOQUE ELECTRICO
NO ABRIR EN TENSION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

AVISO

CAUTION

WZ-600 / PZ-600

CONTROL MODULE WITH 6 ZONES SELECTOR

PAGING DESK WITH ZONE SELECTION

WZ-600 CONTROL MODULE WITH 6 ZONES SELECTOR

TECHNICAL SPECIFICATIONS

Console Input

Sensitivity:
S/N Ratio:
Frequency response:
:

Weight:

1,5V
>68dB

±10dB

6,60 Kg.

4 tones activated by remote control

Chime:

> 0,1%.

Power Source:

50 a 16KHz (-3dB)

230 VAC -  50/60 Hz

Phantom Power:

48V

Sensitivity/Impedance CD

Sensitivity/Impedance TAPE

Distortion:

Bass:

External MIC Input

Sensitivity:

2,5 / 200 mV

S/N Ratio:

>68dB

Frequency response:

50 a 16KHz (-3dB)

AUX 3 Input

Controls

General

500 mV /47 Kohms

200 mV /47 Kohms

Sensitivity/Impedance TUNER

200 mV /47 Kohms

S/N Ratio:

>80dB

Frequency response
:

20 a 16KHz (-3dB)

Treble:

±10dB

The MICRO-600 System is the ideal system for small and medium applications.
The WZ-600 module allows the management of any music input, announcements and pre-recorded messages with any
of the 6 outputs, providing flexibility, through the switches located on the front of the equipment. All inputs allow volume
management and are equipped with a bass and treble filter.
We can connect an amplifier for 6 zones or 6 amplifiers, one per each zone. 6 PZ-600 desks interconnected via audio
and data bus, interconnection via FTP cable, providing a flexible, reliable and easy-to-use system.

6-zone selector for broadcasting music.

Sending pre-recorded messages with priority activation for

Attenuator.

3 pre-recorded messages of 1 minute each.

Chime with volume control.

3 inputs selection for music

External MIC input with phantom power and gain level control

3 levels of priority.

1st Messages
2nd Desk PZ-600 paging desk
3rd external Micro (PRIORITY contact closure)

COM port by RJ45 connector for remote PZ-600 desk.

Control of volume and gain throught the COM port.

Front control for broadcast and recording of messages.

Independent volume control for message broadcast and recording

Remote control for activation of priority over music and chime activation
6 balanced output zones

6 24VDC outputs for priority attenuators (4 wires).

MICRO-600 SYSTEM

MAIN CHARACTERISTICS

6

1

610.500A

rev.

1

EQUIPOS  Y  SISTEMAS  MEGAFONÍA / INTERCOM

PUBLIC  ADDRESS  SYSTEMS

[email protected]

BARCELONA - SPAIN

Tel.: +34 934 772 854  / +34 609 914 787

-Maximum power-line speaker: 500 W.

Summary of Contents for PZ-600

Page 1: ...7 Kohms S N Ratio 80dB Frequency response 20 a 16KHz 3dB Treble 10dB TheMICRO 600Systemistheidealsystemforsmallandmediumapplications The WZ 600 module allows the management of any music input announcements and pre recorded messages with any of the 6 outputs providing flexibility through the switches located on the front of the equipment All inputs allow volume managementandareequippedwithabassandt...

Page 2: ...ont handles 1 2 3 5 4 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 Power input 230 VAC AC Fuse DIMENSIONS IN MILLIMETERS 2U Rack 19 WZ 600 SIDE PANEL 32 302 310 FRONT PANEL 484 88 REAR PANEL FRONT PANEL 34 33 32 31 30 29 20 21 2 1 3 4 22 23 24 25 26 27 28 19 18 17 16 35 36 37 38 10 11 12 13 14 15 9 8 7 6 5 ON OFF POWER MUSIC MICRO REC STOP PLAY ACT...

Page 3: ... or to all Zones throught the alarm button Double COM port with RJ45 connectors for connection to the WZ 600 control unit Microphone volume control Chime volume control Bass and treble controls Auxiliary power input 24VDC By COM port RS 485 communication signal output balanced audio and 24VC power Dip switches for desk identification Possibility of connecting up to 6 PZ 600 paging desks MAIN CHARA...

Page 4: ...ntifier Treble control adjustments BUS input line BUS output line Bass control adjustments 11 4 610 500A Rev 1 1 3 4 5 2 MIC PAGING MIC CONSOLE PZ 600 ZONE 2 ZONE 3 LINK POWER ZONE 5 ZONE 6 ALL CALL TALK TALK ZONE 4 ALARM ZONE 1 POWER 24VDC 1A CHIME VOLUME BASS TREBLE VOLUME LINK IN LINK OUT ID CONSOL 1 2 3 4 5 6 6 7 1 2 3 4 5 6 7 8 12 9 13 10 14 11 15 13 12 11 8 14 15 10 9 WZ 600 PZ 600 PZ 600 CH...

Page 5: ...SSAGE 2 3 1 OFF CONTINUOS NORMAL MIC MESSAGE MESSAGE REG 1 TIME ALARM PHANTOM PRIORITY MICRO CONSOL CONSOL VOLUME GAIN GAIN VOL REG VOL PLAY VOLUME CHIME 230VAC 50Hz T1AL 250V RIESGO DE CHOQUE ELECTRICO NO ABRIR EN TENSION RISK OF ELECTRIC SHOCK DO NOT OPEN AVISO CAUTION B A B A B A B A B A B A 1 1 1 1 1 1 2 2 2 2 2 2 3 3 3 3 3 3 4 4 4 4 4 4 5 5 5 5 5 5 6 6 6 6 6 6 OFF OFF OFF OFF OFF OFF ON ON ON...

Page 6: ...he PZ 600 desk as described in section 7 of this quick guide From the PZ 600 desk you can launch the message 3 as described in section 5 of this quick guide This message has priority over messages 1 and 2 1 Working in ALARM mode Set the ALARM NORMAL selector 23 to the ALARM position Only the signal of warnings 19 is used as signal of warnings and messages It is not possible to broadcast music The ...

Page 7: ...OP PLAY ACTIVE MIC MESSAGE RECORDER 2 3 4 1 2 3 4 5 1 MESSAGE 2 3 1OFF CONTINUOS NORMAL MESSAGE MESSAGE REC 1 TIME ALARM VOL REG VOL PLAY 5 4 Recording by front panel microphone MESSAGES RECORDING 2 Select the message to be recorded using the REC switch Position 1 MESSAGE No 1 Position 2 MESSAGE No 2 Position 3 MESSAGE No 3 The Microprocessed MICRO 600 System allows the diffusion of 3 different me...

Page 8: ...essage Connect external contacts COM N01 NO2 are launched automatically through a closure of external contacts located in the rear panel of the WZ 600 central The No 1 and 2 messages The message n 3 is launched manually through the PZ 600 paging desk 1 2 Adjust the WZ 600 controller switches for broadcast of message n 1 and n 2 MESSAGE 2 3 1 OFF CONTINUOS NORMAL MESSAGE MESSAGE REG 1 TIME ALARM VO...

Page 9: ...00 11 9 610 500A Rev 1 5 7 5 6 7 8 8 6 QUICK OPERATION GUIDE This function is performed from the front panel of the WZ 600 controller to send music to any of the zones to various zones and to all zones We can also insert an auxiliary microphone to mix it with music or have priority over music Connect the different musical sources in their respective connectors By making a contact closure between t...

Page 10: ...xed we can talk into the microphone Adjust the microphone volumen chime volumen and tone control level Remember to identify the desk with the identifier ID CONSOL before connecting them WZ 600 PZ 600 11 10 610 500A Rev 1 1 2 3 3a TALK POWER 24VDC 1A CHIME VOLUME BASS TREBLE VOLUME LINK IN LINK OUT ID CONSOL 1 2 3 4 5 6 PAGING BROADCAST USING PZ 600 6 QUICK OPERATION GIUDE 1 2 3 4 5 6 OFF OFF ON 1 ...

Page 11: ...1 MIC PAGING MIC CONSOLE PZ 600 ZONE 2 ZONE 3 LINK POWER ZONE 5 ZONE 6 ALL CALL TALK ZONE 4 ALARM ZONE 1 MIC PAGING MIC CONSOLE PZ 600 ZONE 2 ZONE 3 LINK POWER ZONE 5 ZONE 6 ALL CALL TALK ZONE 4 ALARM ZONE 1 MIC PAGING MIC CONSOLE PZ 600 ZONE 2 ZONE 3 LINK POWER ZONE 5 ZONE 6 ALL CALL TALK ZONE 4 ALARM ZONE 1 MUSIC AMPLIFIER MUSICAL SOURCE EXTERNAL MICROPHONE WITH PRIORITY PZ 600 1 PZ 600 2 PZ 600...

Page 12: ... ZONE 6 ALL CALL TALK ZONE 4 ALARM ZONE 1 MIC PAGING MIC CONSOLE PZ 600 ZONE 2 ZONE 3 LINK POWER ZONE 5 ZONE 6 ALL CALL TALK ZONE 4 ALARM ZONE 1 MIC PAGING MIC CONSOLE PZ 600 ZONE 2 ZONE 3 LINK POWER ZONE 5 ZONE 6 ALL CALL TALK ZONE 4 ALARM ZONE 1 MIC PAGING MIC CONSOLE PZ 600 ZONE 2 ZONE 3 LINK POWER ZONE 5 ZONE 6 ALL CALL TALK ZONE 4 ALARM ZONE 1 MIC PAGING MIC CONSOLE PZ 600 ZONE 2 ZONE 3 LINK ...

Page 13: ...OWER ZONE 5 ZONE 6 ALL CALL TALK ZONE 4 ALARM ZONE 1 MIC PAGING MIC CONSOLE PZ 600 ZONE 2 ZONE 3 LINK POWER ZONE 5 ZONE 6 ALL CALL TALK ZONE 4 ALARM ZONE 1 MIC PAGING MIC CONSOLE PZ 600 ZONE 2 ZONE 3 LINK POWER ZONE 5 ZONE 6 ALL CALL TALK ZONE 4 ALARM ZONE 1 MIC PAGING MIC CONSOLE PZ 600 ZONE 2 ZONE 3 LINK POWER ZONE 5 ZONE 6 ALL CALL TALK ZONE 4 ALARM ZONE 1 MUSICAL SOURCE PZ 600 1 PZ 600 2 PZ 60...

Page 14: ... ZONE 2 ZONE 3 LINK POWER ZONE 5 ZONE 6 ALL CALL TALK ZONE 4 ALARM ZONE 1 MIC PAGING MIC CONSOLE PZ 600 ZONE 2 ZONE 3 LINK POWER ZONE 5 ZONE 6 ALL CALL TALK ZONE 4 ALARM ZONE 1 MIC PAGING MIC CONSOLE PZ 600 ZONE 2 ZONE 3 LINK POWER ZONE 5 ZONE 6 ALL CALL TALK ZONE 4 ALARM ZONE 1 MIC PAGING MIC CONSOLE PZ 600 ZONE 2 ZONE 3 LINK POWER ZONE 5 ZONE 6 ALL CALL TALK ZONE 4 ALARM ZONE 1 MIC PAGING MIC CO...

Reviews: