background image

 

 
 
 
 
 

Rosmore Slide Control 

 

INCLUDES USER, INSTALLATION & MAINTENANCE 

INSTRUCTIONS 

 
 
 

Please read these instructions carefully before you start using the 

appliance 

 
 

Keep this booklet handy for future reference 

 

This appliance is 

for use in GREAT BRITAIN or IRELAND only 

 
 

 

 
 
 
 
 

Summary of Contents for Rosmore Slide Control

Page 1: ...ES USER INSTALLATION MAINTENANCE INSTRUCTIONS Please read these instructions carefully before you start using the appliance Keep this booklet handy for future reference This appliance is for use in GR...

Page 2: ...ments 13 Clearance to Shelf 13 Clearance to Side of Fire 14 Ventilation 14 SECTION NINE To Install the Appliance 14 Examine Flue Chimney 14 Connecting to the Gas Supply 14 Preparing the Appliance for...

Page 3: ...andling wash hands and other exposed parts If a vacuum is used for cleaning the fuel bed or cleaning after servicing installation it is recommended that it be of the type fitted with a HEPA filter Dis...

Page 4: ...eing incorrectly laid This should be checked prior to contacting a service engineer SECTION TWO Operation The full lighting procedure is as follows a Push slide control lever down as far as possible a...

Page 5: ...oved CARE SHOULD BE TAKEN TO AVOID CONTACT WITH THE REFRACTORY LINING THIS IS A DELICATE SURFACE AND SHOULD NOT BE WIPED OR RUBBED FUEL BED LAYOUT COAL OPTION Coal set provided consists of 6 off shape...

Page 6: ...and Layout Cont Place the first row of 3 x A and 3 x B overlay loose coals as shown between the front coals and base matrix Make sure that they are stable and DO NOT let them fall down in the gaps be...

Page 7: ...EE Fuel Bed Cleaning and Layout Cont Add 2 x type B coals and 1 x type A as shown Add the final 3 x B coals as shown The layout is now finished Note Dye is available for touching up coal and liner boa...

Page 8: ...ilation is provided it should be checked periodically to ensure freedom from obstruction Ventilation in the Republic of Ireland Must be permanent ventilation and must comply with the rules in force an...

Page 9: ...IANCE MUST ONLY BE INSTALLED IN THE GB OR IRELAND Only to be used in sufficiently ventilated room Read instructions carefully before installation and use The appliance must be installed by a competent...

Page 10: ...an be installed in the following flues and locations CLASS ONE A conventional brick or stone chimney as used for a solid fuel appliance with a typical effective cross sectional dimension of 225 x 225...

Page 11: ...must be suitable for the purpose SECTION EIGHT Fireplace Requirements A flat face of 605 mm high x 500 mm wide must be provided around the fireplace opening for the fixing of the appliance to ensure...

Page 12: ...on of the appliance ensuring it is very visible and it should be positioned at a height were it can clearly be seen on approach Frets and Fascias used for HOLE in the WALL must be compliant with C J F...

Page 13: ...d normal adventitious room ventilation exists The installer must satisfy this point by carrying out a mandatory spillage test In the Republic of Ireland permanent ventilation must comply with the rule...

Page 14: ...echanism is swung up to give easy access to the gas connection point as shown Cut a cross slit in the rubber grommet and feed the appliance onto the 8mm gas supply pipe Position the restrictor elbow s...

Page 15: ...CE IS FITTED NOTE DO NOT USE PERMANENT SEALING COMPOUNDS i e SILICONE SEALANT THIS COULD CAUSE THE APPLIANCE TO BE DAMAGED WHEN IT IS REMOVED FOR SERVICING AND COULD INVALIDATE THE WARRANTY If a space...

Page 16: ...e Users Section of these instructions ENSURE THE FUEL BED IS PLACED AS INDICATED IN THESE INSTRUCTIONS Flip the slide control lever round so that the rubber capped end is protruding out to the right a...

Page 17: ...st should be repeated with the fan running If there is a connected room with an extractor fan the test should be repeated with all the doors to that room opened and the extractor fan running COMPLETIO...

Page 18: ...he loose components have been removed Examine the fuel bed components for signs of cracking and replace if necessary IMPORTANT see fuel bed layout procedure before attempting to replace loose fuel bed...

Page 19: ...peration 2 for removal of burner and or silencer 3 Disconnect gas connection to injector and gas control 4 Unscrew the locking nut fixing injector to mounting bracket 5 Clean or replace as necessary 6...

Page 20: ...helpdesk Model UC Living Rosmore Slide Control Serial No This information can be found on the label attached to the packaging and on the data badge which is located on the appliance flange top right b...

Page 21: ...nual service Engineer Name Gas Safe Registration No Date of Second annual service Engineer Name Gas Safe Registration No Date of Third annual service Engineer Name Gas Safe Registration No Date of For...

Page 22: ...22 LT6587 Iss 1 10 13...

Page 23: ...pliance must be installed by a Gas Safe registered person 2 The appliance must be used in accordance with the users instructions 3 The appliance must be serviced annually by a Gas Safe registered pers...

Page 24: ...24 LT6587 Iss 1 10 13...

Page 25: ...________________ Address ________________________________ Post Code TELEPHONE No PRODUCT DETAILS Model UC Living Rosmore Slide Control Serial No Date of Purchase This information can be found on the l...

Page 26: ...LT Iss...

Page 27: ...27 LT6587 Iss 1 10 13...

Page 28: ...28 LT6587 Iss 1 10 13...

Page 29: ...29 LT6587 Iss 1 10 13...

Page 30: ...30 LT6587 Iss 1 10 13...

Page 31: ...31 LT6587 Iss 1 10 13...

Page 32: ...t Burner Tray Box Assembly Slide Control Trim Covers And Instructions Warning Label Fire Guard Fuel Bed Comprises of Base Matrix 4720 Bag Of Coals 6543 Front Coal LH 4723 Front Coal RH 4724 Restrictor...

Reviews: