TOBY-R2 series - System integration manual
UBX-16010572 - R10
Design-in
Page 82 of 151
2.3
System functions interfaces
2.3.1
Module power-on (PWR_ON)
2.3.1.1
Guidelines for PWR_ON circuit design
TOBY-R2 series PWR_ON input is equipped with an internal active pull-up resistor to the V_BCKP
supply as described in
: an external pull-up resistor is not required and should not be
provided.
If connecting the PWR_ON input to a push button, the pin will be externally accessible on the
application device. According to EMC/ESD requirements of the application, an additional ESD
protection should be provided close to the accessible point, as described in
☞
ESD sensitivity rating of the PWR_ON pin is 1 kV (Human Body Model according to JESD22-A114).
Higher protection level can be required if the line is externally accessible on the application board,
e.g. if an accessible push button is directly connected to PWR_ON pin, and it can be achieved by
mounting an ESD protection (e.g. EPCOS CA05P4S14THSG varistor) close to the accessible point.
An open drain or open collector output is suitable to drive the PWR_ON input from an application
processor, as the pin is equipped with an internal active pull-up resistor to the V_BCKP supply, as
described in
A compatible push-pull output of an application processor can also be used. In any case, take care to
set the proper level in all the possible scenarios to avoid an inappropriate module switch-on.
TOBY-R2 series
10 k
3
V_BCKP
20
PWR_ON
Power-on
push button
ESD
Open
Drain
Output
Application
Processor
TOBY-R2 series
10 k
3
V_BCKP
20
PWR_ON
TP
TP
Figure 39: PWR_ON application circuits using a push button and an open drain output of an application processor
Reference
Description
Part Number - Manufacturer
ESD
Varistor array for ESD protection
CT0402S14AHSG - EPCOS
Table 30: Example ESD protection component for the PWR_ON application circuit
☞
It is recommended to provide direct access to the PWR_ON pin on the application board by means
of an accessible test point directly connected to the PWR_ON pin.
2.3.1.2
Guidelines for PWR_ON layout design
The power-on circuit (PWR_ON) requires careful layout since it is the sensitive input available to
switch on the TOBY-R2 series modules. It is required to ensure that the voltage level is well defined
during operation and no transient noise is coupled on this line, otherwise the module might detect a
spurious power-on request.