Ublox SARA-R5 Series User Manual Download Page 10

EVK-R5 - User guide 

UBX-19042592 - R06 

Starting up

  

Page 10 of 23 

C1-Public 

 

 

Dual-In-Line Board-to-Board connector J301

 

 

Dual-In-Line Board-to-Board connector J300 

Signal name

 

Pin no.

 

Pin no.

 

Signal name 

 

Signal name

 

Pin no.

 

Pin no. 

Signal name

 

Not connected 

GND 

 

Not connected  1 

GND 

Not connected 

RSVD 

 

Not connected  3 

Not connected 

Not connected 

Not connected 

 

Not connected  5 

Not connected 

GND 

GND 

 

VCC 

VCC 

GND 

10 

GND 

 

VCC 

10 

VCC 

DTR 

11 

12 

DCD 

 

Not connected  11 

12 

Not connected 

CTS 

13 

14 

RTS 

 

SIM_IO 

13 

14 

VSIM 

RXD 

15 

16 

TXD 

 

SIM_RST 

15 

16 

SIM_CLK 

DSR 

17 

18 

RI 

 

Not connected  17 

18 

Not connected 

Not connected 

19 

20 

Not connected 

 

SCL 

19 

20 

Not connected 

Not connected 

21 

22 

Not connected 

 

I2S_CLK 

21 

22 

SDA 

GPIO6 

23 

24 

GPIO5 

 

I2S_TXD 

23 

24 

I2S_RXD 

Not connected 

25 

26 

GPIO4 

 

RESET_N 

25 

26 

I2S_WA 

Not connected 

27 

28 

Not connected 

 

Not connected  27 

28 

Not connected 

Not connected 

29 

30 

PWR_ON 

 

Not connected  29 

30 

Not connected 

GPIO3 

31 

32 

GPIO2 

 

Not connected  31 

32 

Not connected 

Not connected 

33 

34 

GPIO1 

 

Not connected  33 

34 

Not connected 

V_INT 

35 

36 

EXT_INT 

 

Not connected  35 

36 

Not connected 

Not connected 

37 

38 

Not connected 

 

Not connected  37 

38 

Not connected 

Not connected 

39 

40 

Not connected 

 

Not connected  39 

40 

Not connected 

GND 

41 

42 

Not connected 

 

GND 

41 

42 

Not connected 

Table 5: Pin-out of the 42-pin dual-in-line board-to-board connectors (J300, J301) available on the ADP-R5 adapter board 
of the EVK-R5 evaluation kit 

 

 

The pins / interfaces that are not supported by a specific SARA-R5 module product version should 
be not driven by an external device (see the SARA-R5 series data sheet 

[2]

 and the SARA-R5 series 

system  integration  manual 

[3]

  for  the  features  supported  by  each  SARA-R5  module  product 

version). 

 

Summary of Contents for SARA-R5 Series

Page 1: ...llular evaluation kits User guide Abstract This guide explains how to set up the EVK R5 evaluation kits to begin evaluating the u blox SARA R5 series modules supporting multi band LTE M NB IoT cellula...

Page 2: ...roduct specification This document applies to the following products Product name Type number Modem version Application version PCN reference Product status EVK R500S EVK R500S 0 00 02 05 A00 01 UBX 2...

Page 3: ...al communication 13 B Setting up cellular packet data connection on Windows 14 B 1 Install a new modem from the control panel 14 B 2 Configuring a new connection 16 C AT commands examples 17 C 1 Defin...

Page 4: ...1 8 V Power input J400 Cellular adapter board DL400 Main power switch SW400 DL401 SARA R5 cellular module DIL B2B connector J300 DIL B2B connector J301 GND GNSS antenna connector RF_IN J208 GNSS modul...

Page 5: ...module and the DIL header connectors J300 and J301 making the interfaces of the SARA R5 module accessible 3 The GNSS adapter board called ADP GNSS contains the u blox GNSS module the GNSS antenna conn...

Page 6: ...r module SW302 EVB WL3 Cellular reset Push button to reset the cellular module SW303 EVB WL3 Cellular UART detach Slide switch to attach detach the cellular module single UART from the USB RS232 conne...

Page 7: ...ta on the Cellular RS232 connector DL405 EVB WL3 Cellular RI indicator RI line turns ON active low DS501 EVB WL3 Cellular CTS indicator CTS line turns ON active low DS500 EVB WL3 Cellular GPIO1 indica...

Page 8: ...5 module SMA connector for the GNSS antenna to be connected to the GNSS RF input of the SARA R5 module ANT_GNSS 3 J112 ADP R5 Cellular native USB Mini USB connector for the cellular module native USB...

Page 9: ...vailable 15 PWR_ON J301 pin 30 47 SDIO_D0 Not available 16 GPIO1 J301 pin 34 48 SDIO_D3 Not available 17 VUSB_DET Not available 49 SDIO_D1 Not available 18 RESET_N J300 pin 25 50 GND J301 pins 7 10 19...

Page 10: ...D Not connected 25 26 GPIO4 RESET_N 25 26 I2S_WA Not connected 27 28 Not connected Not connected 27 28 Not connected Not connected 29 30 PWR_ON Not connected 29 30 Not connected GPIO3 31 32 GPIO2 Not...

Page 11: ...R510S cellular module 6 2 For the EVK R500S the SARA R500S cellular module switches on For the EVK R510M8S the SARA R510M8S cellular module switches on 7 For communication via the cellular module s U...

Page 12: ...401 according to Table 6 the module can be switched on again Run an AT terminal application e g the u blox m center tool selecting an AT port with these settings o Data rate 115 200 bit s o Data bits...

Page 13: ...es described in section 1 7 Check the Windows Device Manager to find out which COM port is being used by the EVK R5 Figure 3 Home page 4 Enable the connection to the u blox cellular module by clicking...

Page 14: ...cket data connection on Windows 10 using the operating system s TCP IP stack and EVK R5 This is also referred to as a dial up connection B 1 Install a new modem from the control panel 1 Open the Contr...

Page 15: ...inish to complete the modem installation 6 Now the new modem is visible under the Modems tab in Control Panel Phone and Modem Any extra initialization AT command e g to set a specific APN name can be...

Page 16: ...ly installed 4 Enter the parameters for the dial up connection o The module telephone number 99 1 to be changed if using a PDP context different from 1 o The specific account information for the netwo...

Page 17: ...ch bearer AT COPS 0 OK CEREG 1 0001 01a2d001 7 CGEV ME PDN ACT 1 Trigger a network registration and wait for attach complete C 2 Data connection using internal TCP IP stack Activate an internal contex...

Page 18: ...nal context profile_id 0 Map a context with protocol type IPV4V6 AT CGDCONT 1 IPV4V6 default OK Set context cid 1 with IPV4V6 protocol type and APN string default wait for context cid 1 activation AT...

Page 19: ...network AT CEREG CEREG 0 1 OK Verify the network registration status AT COPS 0 OK Register the module on the network The cellular module automatically registers itself on the cellular network This co...

Page 20: ...meter placed in series as illustrated in Figure 6 SARA R5 adapter board SARA R5 Cellular module 42 pin DIL B2B connectors EVB WL3 Step down Main power switch SW400 12 V J400 3 8 V VCC jumper J109 VCC...

Page 21: ...al Purpose Input Output HW Hardware I2C Inter Integrated Circuit I2S Inter IC Sound IoT Internet of Things IP Internet Protocol LED Light Emitting Diode LTE Long Term Evolution N A Not Applicable NB N...

Page 22: ...x documentation and to receive product change notifications register on our homepage www u blox com Revision history Revision Date Name Comments R01 22 Oct 2019 fvid Initial release R02 11 Nov 2019 lp...

Page 23: ...al Office China Beijing Phone 86 10 68 133 545 E mail info_cn u blox com Support support_cn u blox com Regional Office China Chongqing Phone 86 23 6815 1588 E mail info_cn u blox com Support support_c...

Reviews: