LISA-U series - System Integration Manual
UBX-13001118 - R17
Advance information
System description
Page 121 of 190
1.15.2.1
Safety Warnings review the structure
Equipment for building-in. The requirements for fire enclosure must be evaluated in the end product
The clearance and creepage current distances required by the end product must be withheld when the
module is installed
The cooling of the end product shall not negatively be influenced by the installation of the module
Excessive sound pressure from earphones and headphones can cause hearing loss
No natural rubbers, no hygroscopic materials nor materials containing asbestos are employed
1.15.2.2
Declaration of conformity
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
this device may not cause harmful interference
this device must accept any interference received, including interference that may cause undesired operation
Radiofrequency radiation exposure Information: this equipment complies with FCC radiation
exposure limits prescribed for an uncontrolled environment for fixed and mobile use conditions.
This equipment should be installed and operated with a minimum distance of 20 cm between
the radiator and the body of the user or nearby persons. This transmitter must not be
co-located or operating in conjunction with any other antenna or transmitter except in
accordance with FCC procedures and as authorized in the module certification filing.
The gain of the system antenna(s) used for LISA-U100 and LISA-U120 (i.e. the combined
transmission line, connector, cable losses and radiating element gain) must not exceed 3 dBi (in
850 MHz and 1900 MHz bands) for mobile and fixed or mobile operating configurations.
The gain of the system antenna(s) used for LISA-U200 (i.e. the combined transmission line,
connector, cable losses and radiating element gain) must not exceed 4.25 dBi (850 MHz),
7.30 dBi (1700 MHz) and 2.74 dBi (1900 MHz) for mobile and fixed or mobile operating
configurations.
The gain of the system antenna(s) used for LISA-U201 (i.e. the combined transmission line,
connector, cable losses and radiating element gain) must not exceed TBD (850 MHz), TBD (1700
MHz) and TBD (1900 MHz) for mobile and fixed or mobile operating configurations.
The gain of the system antenna(s) used for LISA-U230 (i.e. the combined transmission line,
connector, cable losses and radiating element gain) must not exceed 4.78 dBi (850 MHz),
7.55 dBi (1700 MHz) and 3.95 dBi (1900 MHz) for mobile and fixed or mobile operating
configurations.
The gain of the system antenna(s) used for LISA-U260 and LISA-U270 (i.e. the combined
transmission line, connector, cable losses and radiating element gain) must not exceed 4.88 dBi
(850 MHz) and 4.08 dBi (1900 MHz) for mobile and fixed or mobile operating configurations.
1.15.2.3
Modifications
The FCC requires the user to be notified that any changes or modifications made to this device that are not
expressly approved by u-blox could void the user's authority to operate the equipment.
Manufacturers of mobile or fixed devices incorporating the LISA-U modules are authorized to
use the FCC Grants and Industry Canada Certificates of the LISA-U modules for their own final
products according to the conditions referenced in the certificates.
The FCC Label shall in the above case be visible from the outside, or the host device shall bear a
second label stating:
LISA-U100: "Contains FCC ID: XPYLISAU120" resp.
LISA-U120: "Contains FCC ID: XPYLISAU120" resp.
LISA-U200: "Contains FCC ID: XPYLISAU200" resp.
LISA-U201: "Contains FCC ID: XPYLISAU201" resp.