EVK-M8GZOE User Guide
UBX-16030132 - R04
Device description
Page 15 of 30
Early Production Information
4.7
RESET_N and SAFEBOOT_N
RESET_N and SAFEBOOT_N are available on jumpers (J5 and J10) as well as on digital connector
J1. See section 4.4 for more information.
4.8
EXTINT
On the EVK-M8GZOE, the EXTINT signal of ZOE-M8G is available on digital connector J1 (see
section 4.4), and on RS-232 connector (see section 4.2.3).
☞
If EXTINT0 on RS-232 is used, ensure the EXTINT signal available at digital connector J1 is
connected to 1.8 V.