Ublox BMD-38 EVK User Manual Download Page 20

 

BMD-34 / 38 EVK - User guide 

UBX-19033356 - R06 

Contact

  

Page 20 of 20 

C1-Public 

 

 

Contact 

For complete contact information, visit us at 

www.u-blox.com

. 

u-blox Offices 

 

 

 

 

North, Central and South America 

u-blox America, Inc. 

Phone:  +1 703 483 3180 
E-mail: 

[email protected]

 

Regional Office West Coast: 

Phone:  +1 408 573 3640 
E-mail: 

[email protected]

 

Technical Support: 

Phone:  +1 703 483 3185 
E-mail: 

[email protected]

 

 

Headquarters 
Europe, Middle East, Africa 

u-blox AG  

Phone:  +41 44 722 74 44 
E-mail: 

[email protected]

  

Support

[email protected]

 

 

Asia, Australia, Pacific 

u-blox Singapore Pte. Ltd. 

Phone:   +65 6734 3811 
E-mail:  

[email protected]

 

Support

[email protected]

 

Regional Office Australia: 

Phone:   +61 2 8448 2016 
E-mail:  

[email protected]

 

Support

[email protected]

 

Regional Office China (Beijing): 

Phone:  +86 10 68 133 545 
E-mail: 

[email protected]

  

Support

[email protected]

 

Regional Office China (Chongqing): 

Phone:  +86 23 6815 1588 
E-mail: 

[email protected]

  

Support

[email protected]

 

Regional Office China (Shanghai): 

Phone:  +86 21 6090 4832 
E-mail: 

[email protected]

  

Support

[email protected]

 

Regional Office China (Shenzhen): 

Phone:  +86 755 8627 1083 
E-mail: 

[email protected]

  

Support

[email protected]

 

Regional Office India: 

Phone:  +91 80 405 092 00 
E-mail: 

[email protected]

 

Support

[email protected]

 

Regional Office Japan (Osaka): 

Phone:  +81 6 6941 3660 
E-mail: 

[email protected]

 

Support

[email protected]

 

Regional Office Japan (Tokyo): 

Phone:  +81 3 5775 3850 
E-mail: 

[email protected]

 

Support

[email protected]

 

Regional Office Korea: 

Phone:  +82 2 542 0861 
E-mail: 

[email protected]

 

Support

[email protected]

 

Regional Office Taiwan: 

Phone:  +886 2 2657 1090 
E-mail: 

[email protected]

  

Support: 

[email protected]

 

 

Summary of Contents for BMD-38 EVK

Page 1: ...38 series modules User guide Abstract This document describes how to set up the EVK BMD 340 EVK BMD 341 and EVK BMD 380 evaluation kits to evaluate BMD 34 series modules It also describes the differen...

Page 2: ...rty rights in the products names logos and designs included in this document Copying reproduction modification or disclosure to third parties of this document or any part thereof is only permitted wit...

Page 3: ...board 6 2 1 2 USB peripheral power 7 2 2 Reset 7 2 3 Buttons 8 2 4 LEDs 9 2 5 32 kHz crystal oscillator 10 2 6 NFC connector 10 2 7 Current sensing headers 11 2 8 External SEGGER J Link debug interfac...

Page 4: ...ll 48 GPIO are available on headers that are compatible with the Arduino form factor This allows easy use of any existing Arduino shields Current sense resistors allow for measuring current into the m...

Page 5: ...e for Windows macOS and Linux Nordic Semiconductor SDK The nRF5 SDK is your first stop for building fully featured reliable and secure applications with the nRF52 and nRF51 series It offers developers...

Page 6: ...lder jumpers are provided to allow by passing any of the protection diodes eliminating the voltage drop across them Care should be taken to not damage the supplies when the protection is by passed 2 1...

Page 7: ...18 is assumed to be used as the reset pin for all BMD 34 and Nordic example projects and thus the evaluation board hardware is configured to use P0 18 as a reset The Reset button can be configured to...

Page 8: ...below RESET_N is connected to the interface IC and to the reset connections on the Arduino headers Figure 4 Schematic Reset 2 3 Buttons The evaluation board has four user buttons Button 1 Button 2 Bu...

Page 9: ...h drive when sinking current for the LEDs The LEDs can be completely removed from the circuit by breaking the associated jumper Figure 6 Schematic User LEDs The evaluation board allows for easy serial...

Page 10: ...l calibrated RC oscillator an internal synthesized clock derived from the 32 MHz clock or an external crystal oscillator The external crystal oscillator is the most accurate and lowest power LF clock...

Page 11: ...a multimeter or other precision voltage measurement device to measure voltage drop across pins one and two Current can also be measured directly by removing RBMD RSHD and using a current meter in ser...

Page 12: ...ware EXT_GND_DETECT is used by the debug interface to detect the presence of an external target hardware Connect EXT_GND_DETECT to GND on the target hardware Connect GND to GND on the target hardware...

Page 13: ...z crystal P0 09 P0 10 NFC antenna and P0 17 P0 20 P0 23 QSPI These are disconnected from the I O headers as they would interfere with the default functions The GPIO jumpers are shown on the bottom of...

Page 14: ...15 P1 15 GPIO 6 P1 14 P1 14 GPIO 7 P1 13 P1 13 GPIO 8 P1 12 P1 12 GPIO 9 P1 11 P1 11 GPIO 10 P1 10 P1 10 GPIO Table 4 Header J6 Pin Pin name nRF52840 Function 1 P1 08 P1 08 GPIO 2 P1 07 P1 07 GPIO 3 P...

Page 15: ...P0 15 P0 15 GPIO 6 P0 16 P0 16 GPIO 7 P0 17 P0 17 OPEN GPIO QSPI CS 8 P0 18 P0 18 RESET_N GPIO 9 P0 19 P0 19 OPEN GPIO QSPI CLK 10 P0 20 P0 20 OPEN GPIO QSPI DIO0 11 P0 21 P0 21 OPEN GPIO QSPI DIO1 1...

Page 16: ...desktop a second evaluation board or a nRF52 USB Dongle is required to make Bluetooth low energy connections with your DUT 4 Install the SEGGER J Link Commander If presented with a screen to select d...

Page 17: ...evice driver 4 Run the J Link Commander 4 1 JLink on Windows 4 2 JLinkExe on macOS and Linux If prompted to update the J Link firmware accept and perform the update 5 Type connect at the J Link prompt...

Page 18: ...ss reference For this guide the nRF SDK v15 3 0 Heart Rate Service example for the BMD 340 EVAL will be used The latest SDK version should be used whenever possible The nRF5_SDK_xx x x_yyyyyyy directo...

Page 19: ...ion register on our website www u blox com Revision history Revision Date Comments 1 0 01 Feb 2018 Initial release 2 0 05 Jun 2019 Added new modules and changed title to BMD 34 EVAL User Guide Update...

Page 20: ...ional Office China Beijing Phone 86 10 68 133 545 E mail info_cn u blox com Support support_cn u blox com Regional Office China Chongqing Phone 86 23 6815 1588 E mail info_cn u blox com Support suppor...

Reviews: