ANNA-B112 - System integration manual
UBX-18009821 - R09
Design-in
Page 48 of 66
C1-Public
Application
Category
Immunity Level
All exposed surfaces of the radio equipment and ancillary
equipment in a representative configuration
Indirect Contact Discharge
±
8 kV
Table 15: Electro-Magnetic Compatibility ESD immunity requirements as defined by CENELEC EN 61000-4-2, ETSI EN 301
489-1, ETSI EN 301 489-7, ETSI EN 301 489-24
ANNA-B112 is manufactured with consideration to specific standards that minimize the occurrence
of ESD events. The highly automated process complies with IEC61340-5-1 (STM5.2-1999 Class M1
devices) standard. Designers should implement proper measures to protect from ESD events and
safeguard any pin that may be exposed to the end user.
Compliance with standard protection level specified in EN61000-4-2 can be achieved by including
ESD protections in parallel to the line, close to areas accessible by the end user.