3.3
Indicative power requirements
Table 17 lists examples of the total system supply current for a possible application.
Parameter
Symbol
Min
Typ
Max
Units
Condition
Max. supply current
13
Iccp
67
mA
VDCDC = 1.4 3.6 V,
VDD_3V=3.0V
Sustained core current
14
Icc Acquisition
47
15
mA
VDCDC = 1.4 3.6 V,
VDD_3V=3.0V
Icc Tracking
(Eco mode)
37
16
mA
Table 17: Indicative power requirements
Values in Table 17 are provided for customer information only as an example of typical power
requirements. Values are characterized on samples, actual power requirements can vary depending on
FW version used, external circuitry, number of SVs tracked, signal strength, type of start as well as time,
duration and conditions of test.
For more information about power requirements, see the
AMY-6M Hardware Integration Manual
[1].
3.4
SPI timing diagrams
In order to avoid a faulty usage of the SPI, the user needs to comply with certain timing conditions. The
following signals need to be considered for timing constraints:
Symbol
Description
SS_N
Slave Select signal
SCK
Slave Clock signal
Table 18: Symbol description
Figure 3: SPI timing diagram
13
Use this figure to dimension maximum current capability of power supply. Measurement of this parameter with 1 Hz bandwidth.
14
Use this figure to determine required battery capacity.
15
>8 SVs in view, CNo >40 dBHz, current average of 30 sec after cold start.
16
With strong signals, all orbits available. For Cold Starts typical 12 min after First Fix. For Hot Starts typical 15 sec after First Fix.