background image

1

 2 

BALL VALVE SERVO 

INSTALLATION

BALL VALVE SERVO INSTALLATION GUIDE

Do NOT use on other types of valves.

1. CLOSE VALVE

2. PREPARE YOUR BVS

3. INSTALL BVS ON YOUR VALVE

4. CONNECT SPC AND POWER ADAPTER

Touch Sense Button

if you

 

have

 

oversized

 

valve

 

or your valve has

 

adjacent pipe elbow

you

 

may

 

slide any or both clamps in or out to fit the space.

1

Make

 

sure

 

the

 

knobs

 

are

 

facing

 

on the same

 

side

 

as

 

the

 

water

 

valve

 

handle

 2 

Check the transmission fork mechanic engagement by visual

You SHOULD

 

NOT see the PATTERN

 

on the top of transmission fork, if you do, you 

may not install it securely, please double check, make sure you have pushed the BVS 
down enough for a secured installation.

Otherwise you have a rare ultra low profile valve, the handle is too low for spring 
loaded mechanic to engage, in this case, please put the Spacer      between the hex 
bolt head of the valve      and the transmission fork.

If you don’t see the pattern without Spacer, DO NOT use the Spacer.

PATTERN NOT SEEN

PATTERN SEEN

Rotate the handle from position     to position      to turn off your valve

1

 2 

Align the pivot of the transmission fork is with the hex bolt 
on top of the valve Press down firmly to engage the spring 
loaded gear, then tighten 2 clamps. 

Position the BVS over the top of the handle of ball valve

1

 2 

1

 2 

If you are installing the Ball Valve Servo outdoor, you may consider to disable the 
touch sensing button to prevent it activated from rain drops or pets.

To Disable the button:

Tap and hold the touch sense button for 3 beeps, then quickly tap 3 times in a row.
If successful, the Yellow LED will flash once, then the Red LED with 1 beep. The LED 
will slowly flashing Yellow indicating the touch sense button has been locked.

To Re-Enable the button:

Tap and hold the touch sense button for 3 beeps, then quickly tap 3 times in a row.
If successful, the Yellow LED will flash once, then the Red LED with 3 beeps. LED will 
then slowly flashing Green (if enrolled) indicating the touch sense button has been 
unlocked.

PACKAGE 

CONTENTS

Ball Valve Servo (BVS)

Water Detection

 

Probe 55.1 inch

1

 2 

Power Adapter

Spacer

1

You

 

may install local water detection probe 

(included)

 for close area leak detection

plug the male 

jack     to the female jack     from the power supply cable branch, It

 

will trigger the valve to close 

whenever water is detected. (remove the protection cap from female jack first)

1

 2 

 2 

if you have purchased Smart Power Capsule, connect it 
between Ball Valve Servo and power adapter. SPC is the 
optional back up power device, it provides up to 32 hours of 
back up power for BVS if there is a power failure.

Insert the male jack     into the 
water tight female jack

     

with 

extra force

 to secure contact and 

water proof result

1

 2 

Summary of Contents for BVSZWE

Page 1: ...op of the handle of ball valve 1 2 1 2 If you are installing the Ball Valve Servo outdoor you may consider to disable the touch sensing button to prevent it activated from rain drops or pets To Disabl...

Page 2: ...8 3 Turn Valve to CLOSE 8 4 Pause OPEN CLOSE Operation 8 5 Resume OPEN CLOSE Operation 9 WATER LEAK ALARM 9 1 Water Leak Detection Alarm 9 2 Water Leak Alarm Cancellation 10 TEMPERATURE SENSOR 11 Z W...

Page 3: ...Built in temperature sensor Visual indicators 3 Colors LED with green yellow red Touch sense button Network water valve and alarm operations Knob Use to adjust Clamp widths DSK label Z Wave SmartStart...

Page 4: ...eep sounds for 2 seconds Factory Default Reset will a Remote the BVS from Z Wave Network b Delete the association setting c Restore the con guration settings to the default 8 WATER VALVE OPERATION Cal...

Page 5: ...SECURITY_2 1 Support Support Support Support SUPERVISION 1 Support Support Support Support FIRMWARE_UPDATE_MD 5 Support Support Support Support SENSOR_MULTILEVEL Temperature 11 Support Support Suppor...

Page 6: ...ties False Advanced False Description Con gure Noti cation Report in Association Group 1 Lifeline Set Bit to 0 Disable Set Bit to 1 Enable Value Function Bit 0 Water Valve Open Close 0 Disable 1 Enabl...

Page 7: ...0 Format Enumerated Max Value 0x02 2 Read only False Default Value 0x00 0 Altering capabilities False Advanced False Description Con gure Overheat Trigger Value in Association Group 4 Value Function 0...

Page 8: ...x71 113 Name Battery Threshold Change Report Info Set Battery Threshold Level Change Properties Size 1 Byte Min Value 0x00 0 Format Unsigned Max Value 0x63 99 Read only False Default Value 0x0A 10 Alt...

Page 9: ...replace the defective or damaged parts of the Product Normal wear and tear is not covered nor is abnormal use misuse mishandling faulty installation improper shipping damage caused by disasters such a...

Reviews: