The control unit C4 is a radio controlled device with 4 universal inputs to 

control further smart home components. In the current flush mount version, 

it is compatible to standard switch boxes and fully integrates into the rest 

of your smart home. It is not only suitable for new buildings, but also for 

existing buildings, because retrofitting has, due to use of radio technology, no 

special requirements to the electrical installation. The system can gradually 

be extended by adding new components. The control unit C4 is an additional 

option and offers full functionality when combined with other components of 

the ubisys smart home product line and allows for example:

• 

Freely configurable assignments between control elements and consu-

mers

• 

Scenes and group controlling

• 

Can be connected to switches and motion sensors

More information about the features of the ubisys smart home product line 

can be found at www.ubisys.de.

Installation

The control unit C4 is designed for installation in flush mounted sockets 

according to DIN 49073. For installation behind a switch, power socket or 

motion sensor, deep sockets are recommended.

Leads:

Dimensions:

 

 

For installation of the control unit C4, the included clamps can be used. 

During installation, the general risks of household voltage networks have to 

be noted!

Zigbee Initial Commissioning (Brand New Device)

1. 

Connect the unit to a power source (according to the connections).

2. 

Open a Zigbee network: when using the ubisys gateway, tap 

Confi-

guration

 -> 

Basic Configuration

 -> 

Open for new devices

 in the 

ubisys app (if you are using third-party gateways or apps, follow the 

corresponding procedure).

3. 

The Zigbee network is open and the device joins.

4. 

The device appears in the component list: 

Configuration

 -> 

Basic 

Configuration

 -> 

Components

.

Funkvernetzt mit

Stromverbrauchsmessung

Leistungsschalter S2

230 V ~ / 50 Hz, 2 x 500 VA

2

1

2

1

Leistungsschalter S1

Funkvernetzt mit

Stromverbrauchsmessung

230 V ~ / 50 Hz, 3.680 VA

Funkvernetzt mit

Stromverbrauchsmessung

Jalousiesteuerung J1

230 V ~ / 50 Hz, 500 VA

2

1

2

1

Funkvernetzt mit

Stromverbrauchsmessung

Universaldimmer D1

230 V ~ / 50 Hz, 500 VA

2

1

Funkvernetzt

Bedieneinheit C4

AC 230 V ~ / 50 Hz

2

1

4

3

Funkvernetzt

Router R0

AC 230 V ~ / 50 Hz

Router R0

90 - 270 V~, 50/60 Hz
(12 - 400 V=)

2

1

2

1

4

3

2

1

4

3

2

1

2

1

2

2

Router R0

2

2

2

1

2

1

90 - 270 V~, 50/60 Hz
(12 - 400 V=)

47 mm

43 mm

43 mm

43 mm

43 mm

12 mm

143 mm

12 mm

143 mm

12 mm

143 mm

12 mm

143 mm

12 mm

47 mm

12 mm

47 mm

12 mm

47 mm

17 mm

47 mm

43 mm

12 mm

143 mm

12 mm

47 mm

43 mm

143 mm

12 mm

47 mm

43 mm

12 mm

143 mm

12 mm

47 mm

43 mm

12 mm

12 mm

143 mm

12 mm

Factory Reset
Power-Cycle Sequencing Factory Reset:

 It is possible to instigate a factory 

reset using a special power-cycle sequence without having access to the 

device itself (only to its power supply). The only requirement is a simple on/

off sequence in a 1-second rythm:

 

1. 

The device has to be powered up for at least 4 seconds.

2. 

Power off for a second.

3. 

Power on for a second.

 

Repeat steps 2.-3. in the aforementioned 

1-second rythm

 another 3 times, 

and with the last sequence keep the device powered up (see illustration).

 

4. 

The device will automatically reboot to the original factory settings.

Factory Reset via Button:

 To reset the device to its factory fresh settings 

(e.g. in order to join it to another network afterwards), press the button in the 

larger of the two holes on the front for more than 10 seconds until the LED 

starts flashing rapidly.

Only use the electrically isolated tool provided with the device to press the 

button in the hole.

Configuration

The control unit C4 has 4 inputs. Every single input can be configured indivi-

dually and can be used to control smart home components.

For integration into the smart home radio network, the control unit C4 has to 

be configured first. Direct access to the control unit C4 is not necessary for 

configuration. That means that network configuration can also be done after 

successful electrical installation. It is best to hold the 16 digit serial number 

of the control unit C4 in the construction plan during installation. This allows 

you to allocate the device at a later point.

When connected to power, the control unit C4 automatically logs into the 

Zigbee network. After that it can be configured via the electrician’s installati-

on software (ubisys Network Manager) or the ubisys smartphone app.

More information about adding and configuring ubisys smart home compon-

ents can be found in the ubisys Smart Home app manual.

Technical Information

Rated voltage

230 V ~, 50 Hz

Own consumption

0.3 W

Radio technology

Zigbee 3.0 in 2.4 GHz ISM Band, 
IEEE 802.15.4 channels 11-26, 0…5dBm 
transmitting power *)

Environment temperature

-20°C - +45°C

*) More information about radio technology can be found at www.ubisys.de.

Certifications and Environmental Contribution

Funkvernetzt mit

Stromverbrauchsmessung

Leistungsschalter S2

230 V ~ / 50 Hz, 2 x 500 VA

2

1

2

1

Leistungsschalter S1

Funkvernetzt mit

Stromverbrauchsmessung

230 V ~ / 50 Hz, 3.680 VA

Funkvernetzt mit

Stromverbrauchsmessung

Jalousiesteuerung J1

230 V ~ / 50 Hz, 500 VA

2

1

2

1

Funkvernetzt mit

Stromverbrauchsmessung

Universaldimmer D1

230 V ~ / 50 Hz, 500 VA

2

1

Funkvernetzt

Bedieneinheit C4

AC 230 V ~ / 50 Hz

2

1

4

3

Funkvernetzt

Router R0

AC 230 V ~ / 50 Hz

Button

LED

Button

LED

Button

LED

Button

LED

Button

LED

Button

LED

Router R0

Button

LED

90 - 270 V~, 50/60 Hz
(12 - 400 V=)

Control Unit C4

Radio linked