Connecting Console Terminal
Installation
20
PON
OLT
Connecting Console Terminal
U9016B can be set or monitored through a local console port. The use of console cable that
came with the product is recommended to connect between the product and the console
terminal. Connect the RJ-45 connector of console cable to the console port of the product
and the DB-9 connector (the other side of the cable) to the console terminal.
The terminal device used as the console terminal of U9016B should be set according to the
following communication environment conditions so that it can communicate with U9016B
normally.
Bit Rate: 9600 bps
Data Bit: 8 bit
Stop bit: 1 bit
Parity bit: None.
Flow control: None.
Figure 9. Connecting Console Terminal
Caution Most of the cases that the screen output of the console terminal fails, it
is due to the wrong setting of the number of bits per sec in the console
terminal. In case that the characters on the console terminal screen are
broken or that no character is displayed, check the number of bits per
sec set in the terminal.
Note
See the console cable specifications and
“Appendix B “Cable Spec.”
(The connectors of a cable are pin-connected.)
Console Terminal