Specifications

RocketDish RD-5G30-LW

Dimensions

650 x 650 x386 mm (25.6 x 25.6 x 15.2")

Weight

7.4 kg (16.31 lb)

(Mount Included)

Frequency

5.1 - 5.9 GHz

Gain

30 dBi

Max. VSWR

1.6:1

Wind Survivability

200 km/h (125 mph)

Wind Loading

790 N @ 200 km/h (178 lbf @ 125 mph)

Polarization

Dual Linear

F/B Ratio

30 dB

ETSI Specification

EN 302 326 DN2

Mounting

Universal Pole Mount, Rocket Bracket, and 

Weatherproof RF Jumpers Included

Safety Notices

1.  Read, follow, and keep these instructions.
2.  Heed all warnings.
3.  Only use attachments/accessories specified by the manufacturer.

WARNING:

 Do not use this product in location that can 

be submerged by water. 

WARNING:

 Avoid using this product during an electrical 

storm. There may be a remote risk of electric shock from 
lightning. 

Electrical Safety Information

1.  Compliance is required with respect to voltage, frequency, and current 

requirements indicated on the manufacturer’s label. Connection to a 
different power source than those specified may result in improper 
operation, damage to the equipment or pose a fire hazard if the 
limitations are not followed.

2.  There are no operator serviceable parts inside this equipment. Service 

should be provided only by a qualified service technician.

Summary of Contents for RocketDish 5G30

Page 1: ...airMAX 2x2PtPBridge DishAntenna Model RD 5G30 LW ...

Page 2: ... Hex Head Bolts M8 Qty 5 Lock Washers M8 Qty 5 Flat Washers M8 Qty 5 Stabilizer Brackets Qty 2 airMAX 2x2 PtP Bridge Dish Antenna Model RD 5G30 LW M10x100 Bolts Qty 2 Serrated Flange Nuts M10 Qty 2 M8x150 Carriage Bolts Qty 4 Pole Clamps Qty 2 Quick Start Guide TERMS OF USE Ubiquiti radio devices must be professionally installed Shielded Ethernet cable and earth grounding must be used as condition...

Page 3: ...or all wired Ethernet connections and should be grounded through the AC ground of the PoE We recommend that you protect your networks from the most brutal environments and devastating ESD attacks with industrial grade shielded Ethernet cable from Ubiquiti Networks For more details visit www ubnt com toughcable Hardware Overview Fully Assembled Back View Mounting Bracket Pole Clamp Protective Shrou...

Page 4: ...tiveness 1 Line up the alignment tabs of the Mounting Bracket with the alignment slots of the Dish Reflector Insert the tabs and rotate the Mounting Bracket until they lock into place Note Ensure that the antenna feed slot of the Mounting Bracket lines up with the antenna feed slot of the Dish Reflector as shown below ...

Page 5: ...hese steps a Remove the knob from the Antenna Feed b Line up the alignment pins of the Antenna Feed with the alignment holes of the Dish Reflector and Mounting Bracket Note Ensure that the straight edge of the Antenna Feed end shown below and arrow on the Antenna Feed cap are pointing straight up c Insert the Antenna Feed ...

Page 6: ...he surface of the Mounting Bracket b Use a wrench or channel lock pliers to tighten the knob an additional turn Do NOT over tighten the knob Note Ensure that the Antenna Feed is securely attached by the knob Important Do not handle the RocketDish by the Antenna Feed once the feed is attached 640 00148 03 640 00148 03 ...

Page 7: ...he back of the Rocket with the Rocket mount b Slide the Rocket down to lock it into place 5 Attach the other end of the RF Cables to the RF connectors on the Rocket in this combination H to Chain 1 and V to Chain 0 Then slide the jackets over the RF connectors to protect them ...

Page 8: ...6 Attach the Protective Shroud a Align the hash mark on the top of the shroud with the notch on the Dish Antenna b Rotate the shroud clockwise until it locks into place ...

Page 9: ...rs to the bottom of the Mounting Bracket Ensure that there is a gap of 8 mm between each Flat Washer and the Mounting Bracket Note Ensure that each Lock Washer is always installed between the Hex Head Bolt and Flat Washer Hex Head Bolt Flat Washer Lock Washer 8 mm ...

Page 10: ...he Upper Pole Bracket using a Hex Head Bolt Lock Washer and Flat Washer Note Ensure that the degree settings are the same on both arms of the Upper Pole Bracket Degree markings facing outward 9 Attach the Brace to the pole brackets using the four Screws ...

Page 11: ... Remove these and use them in the next step 11 Attach one Pole Clamp to each pole bracket a Insert two M8x150 Carriage Bolts into each pole bracket b Slide the hole of a Pole Clamp over one bolt of each pole bracket c Place one serrated flange nut on each bolt ...

Page 12: ...ere the RocketDish will be attached Note The pole bracket assembly can accommodate a Ø 38 101 mm pole a Place one Stabilizer Bracket on each side of the pole b Insert the two M10x100 Bolts into the Stabilizer Brackets c Secure each bolt with one Serrated Flange Nut 50 N m ...

Page 13: ... assembly to the pole a Slide the slot of each Pole Clamp over the corresponding M8x150 Carriage Bolt b Tighten the serrated flange nuts of the bolts to secure the pole bracket assembly to the pole Proper slot orientation 25 N m ...

Page 14: ... and align the two lower Hex Head Bolts with the slots on the Lower Pole Bracket Seat the bolts in the slots 15 Attach each arm of the Upper Pole Bracket to the Mounting Bracket using a Hex Head Bolt Lock Washer and Flat Washer ...

Page 15: ...o allow movement IMPORTANT If you cannot spin the washers freely by hand then loosen the Hex Head Bolts until you can 17 To adjust the tilt angle turn the screw head of the Elevation Rod until the desired tilt is reached 18 Lock the alignment by tightening all six Hex Head Bolts to 25 N m ...

Page 16: ...achments accessories specified by the manufacturer WARNING Do not use this product in location that can be submerged by water WARNING Avoid using this product during an electrical storm There may be a remote risk of electric shock from lightning Electrical Safety Information 1 Compliance is required with respect to voltage frequency and current requirements indicated on the manufacturer s label Co...

Page 17: ...IV has been subjected to misuse abuse negligence abnormal physical electromagnetic or electrical stress including lightning strikes or accident V has been damaged or impaired as a result of using third party firmware VI has no original Ubiquiti MAC label or is missing any other original Ubiquiti label s or VII has not been received by Ubiquiti within 30 days of issuance of the RMA In addition the ...

Page 18: ... FACILITIES UBIQUITI NETWORKS ITS AFFILIATES AND ITS AND THEIR THIRD PARTY PROVIDERS ARE NOT RESPONSIBLE FOR ANY INTERRUPTIONS DELAYS CANCELLATIONS DELIVERY FAILURES DATA LOSS CONTENT CORRUPTION PACKET LOSS OR OTHER DAMAGE RESULTING FROM ANY OF THE FOREGOING In addition UBIQUITI NETWORKS does not warrant that the operation of the Products will be error free or that operation will be uninterrupted ...

Page 19: ...DDED IN THE PRODUCT TO YOU The United Nations Convention on Contracts for the International Sale of Goods shall not apply to any transactions regarding the sale of the Products Compliance RF Exposure Warning The antenna and transmitter must be installed to provide a separation distance from all persons and must not be located or operating in conjunction with any other antenna or transmitter For th...

Page 20: ...ce or the shop where you purchased the product Deutsch Die Europäische Richtlinie 2002 96 EC verlangt dass technische Ausrüstung die direkt am Gerät und oder an der Verpackung mit diesem Symbol versehen ist nicht zusammen mit unsortiertem Gemeindeabfall entsorgt werden darf Das Symbol weist darauf hin dass das Produkt von regulärem Haushaltmüll getrennt entsorgt werden sollte Es liegt in Ihrer Ver...

Page 21: ...nsi que tout autre matériel électrique ou électronique par les moyens de collecte indiqués par le gouvernement et les pouvoirs publics des collectivités territoriales L élimination et le recyclage en bonne et due forme ont pour but de lutter contre l impact néfaste potentiel de ce type de produits sur l environnement et la santé publique Pour plus d informations sur le mode d élimination de votre ...

Page 22: ...tiivin 1999 5 EY oleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen mukainen Français French Par la présente UBIQUITI NETWORKS déclare que l appareil UBIQUITI NETWORKS device est conforme aux exigences essentielles et aux autres dispositions pertinentes de la directive 1999 5 CE Deutsch German Hiermit erklärt UBIQUITI NETWORKS dass sich dieses UBIQUITI NETWORKS Gerät in Übereinst...

Page 23: ...ensstämmelse med de väsentliga egenskapskrav och övriga relevanta bestämmelser som framgår av direktiv 1999 5 EG Español Spanish Por medio de la presente UBIQUITI NETWORKS declara que el UBIQUITI NETWORKS device cumple con los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 1999 5 CE Polski Polish Niniejszym firma UBIQUITI NETWORKS o wiadcza e produk...

Page 24: ...quiti Networks the Ubiquiti U logo the Ubiquiti beam logo airMAX airOS Rocket RocketDish and TOUGHCable are trademarks or registered trademarks of Ubiquiti Networks Inc in the United States and in other countries All other trademarks are the property of their respective owners JL030215 ...

Reviews: