In-Wall Manageable Outlet
Model: mFi-MPW
Page 1: ...In Wall Manageable Outlet Model mFi MPW ...
Page 2: ...uration The warranty terms are also included in this Quick Start Guide For details on configuring the mFi Controller or to download the mFi Controller software visit www ubnt com mfi Package Contents mFi Outlet Wall Plate In Wall Manageable Outlet Model mFi MPW Wire Nuts Qty 3 Quick Start Guide TERMS OF USE It is the customer s responsibility to follow local country regulations including operation...
Page 3: ...ed by a qualified electrician in accordance with local electrical codes and regulations WARNING TO AVOID FIRE SHOCK OR DEATH turn off power at the circuit breaker or fuse before installing Wiring Overview Neutral White Ground Green 120V 60 Hz Hot Black The mFi Outlet supports up to 15 amps per socket with a total combined load of 15 amps ...
Page 4: ...t powered on in factory default mode Flashing yellow Connecting to a Wi Fi network Solid blue Successfully connected to mFi Controller Flashing blue Connecting to mFi Controller RESET Reset Button Press and release the button to power reset the device INIT Initialize Button Press and hold until the LED alternates colors to restore the device to the factory default settings ...
Page 5: ...l the wiring in the wall box There should be two wires and a ground wire Hot Neutral Ground Electrical Outlet Wall Box Note Wiring colors may be different from the illustration Be sure to verify the wiring before continuing 3 Prepare the wiring in the wall box by stripping away 12 mm of insulation from the end of each wire 12 mm ...
Page 6: ...ion with a Wire Nut a Connect the Black wire of the mFi Outlet to the Hot wire of the wall box b Connect the White wire of the mFi Outlet to the Neutral wire of the wall box c Connect the Green wire of the mFi Outlet to the Ground wire of the wall box 720 00078 01 720 00078 01 ...
Page 7: ...ll box and ensure the yoke is mounted flush with the wall for proper fitting of the Wall Plate Secure the mFi Outlet with the two screws Note Do not over tighten or rely on the force of the screws to pull the mFi Outlet into the wall box If the wall box does not have enough room to accommodate the mFi Outlet and the wiring replace the wall box with a deeper or wider box ...
Page 8: ...clips with the Wall Plate Mounting Slots on the mFi Outlet Press the Wall Plate into position until the mounting clips snap into place If you are using your own wall plate secure it with two screws 8 Turn on power at the circuit breaker or fuse panel ...
Page 9: ...click the Network icon Windows Vista Go to Start Connect To Windows XP Right click the Wireless Network icon in the System Tray lower right corner of the screen Click View Available Wireless Networks 2 Select the wireless network SSID that begins with mFi and then click Connect Go to Accessing the Configuration Portal Mac 1 Click the AirPort icon in the menu bar top right side of the screen 2 Sele...
Page 10: ...ess field Press enter PC or return Mac 2 You may receive a security certificate warning Click Proceed Anyway 3 The Configuration Portal will appear Select the wireless network name SSID of your existing wireless network from the drop down list To refresh the list click the blue arrows on the right ...
Page 11: ...1 1 1 1 6080 or mfi acme com 6080 User The username used to log in to the Controller Password The password used to log in to the Controller Note Remove the Controller checkmark if you need to enter the Controller settings later This can be done via the embedded UI or layer 2 adoption 6 Click Apply 7 A flashing yellow checkmark will appear while the mFi Outlet is attempting to connect to the Wi Fi ...
Page 12: ...eless network by selecting the SSID from your wireless network utility 10 If a Controller was specified access the Controller The mFi Outlet will appear as a mFi Outlet icon in the left panel under the Drag on to Map heading You can position the mFi Outlet in the appropriate location For additional details on the mFi Controller software please refer to the mFi User Guide available on our website a...
Page 13: ...Load 15A per Socket Not Simultaneous 15A Total Combined Interface Status LED Reset Button Initialize Button LED Yellow Blue Wi Fi 802 11b g n Functions Dual Relays for Power Control Energy Monitoring ESD EMP Protection Air 8KV Contact 4KV Operating Temperature 0 to 40 C 32 to 104 F Operating Humidity 10 to 95 Non Condensing Shock and Vibration 40 C 2 Hrs 85 C 2 Hrs 5 Cycles ...
Page 14: ...different power source than those specified may result in improper operation damage to the equipment or pose a fire hazard if the limitations are not followed 2 There are no operator serviceable parts inside this equipment Service should be provided only by a qualified service technician 3 The equipment requires the use of the ground wire as a part of the safety certification modification or misus...
Page 15: ...IV has been subjected to misuse abuse negligence abnormal physical electromagnetic or electrical stress including lightning strikes or accident V has been damaged or impaired as a result of using third party firmware VI has no original Ubiquiti MAC label or is missing any other original Ubiquiti label s or VII has not been received by Ubiquiti within 30 days of issuance of the RMA In addition the ...
Page 16: ... FACILITIES UBIQUITI NETWORKS ITS AFFILIATES AND ITS AND THEIR THIRD PARTY PROVIDERS ARE NOT RESPONSIBLE FOR ANY INTERRUPTIONS DELAYS CANCELLATIONS DELIVERY FAILURES DATA LOSS CONTENT CORRUPTION PACKET LOSS OR OTHER DAMAGE RESULTING FROM ANY OF THE FOREGOING In addition UBIQUITI NETWORKS does not warrant that the operation of the Products will be error free or that operation will be uninterrupted ...
Page 17: ...as been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference...
Page 18: ...is aux deux conditions suivantes 1 cet appareil ne peut pas provoquer d interférences et 2 cet appareil doit accepter toute interférence y compris les interférences qui peuvent causer un mauvais fonctionnement du dispositif CAN ICES 3 B NMB 3 B Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment RF Exposur...
Page 19: ...ce or the shop where you purchased the product Deutsch Die Europäische Richtlinie 2002 96 EC verlangt dass technische Ausrüstung die direkt am Gerät und oder an der Verpackung mit diesem Symbol versehen ist nicht zusammen mit unsortiertem Gemeindeabfall entsorgt werden darf Das Symbol weist darauf hin dass das Produkt von regulärem Haushaltmüll getrennt entsorgt werden sollte Es liegt in Ihrer Ver...
Page 20: ...nsi que tout autre matériel électrique ou électronique par les moyens de collecte indiqués par le gouvernement et les pouvoirs publics des collectivités territoriales L élimination et le recyclage en bonne et due forme ont pour but de lutter contre l impact néfaste potentiel de ce type de produits sur l environnement et la santé publique Pour plus d informations sur le mode d élimination de votre ...
Page 21: ...ITI NETWORKS vakuuttaa täten että UBIQUITI NETWORKS device tyyppinen laite on direktiivin 1999 5 EY oleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen mukainen Français French Par la présente UBIQUITI NETWORKS déclare que l appareil UBIQUITI NETWORKS device est conforme aux exigences essentielles et aux autres dispositions pertinentes de la directive 1999 5 CE Deutsch German Hier...
Page 22: ...ish Härmed intygar UBIQUITI NETWORKS att denna UBIQUITI NETWORKS device står I överensstämmelse med de väsentliga egenskapskrav och övriga relevanta bestämmelser som framgår av direktiv 1999 5 EG Español Spanish Por medio de la presente UBIQUITI NETWORKS declara que el UBIQUITI NETWORKS device cumple con los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Dire...
Page 23: ......
Page 24: ... Inc All rights reserved Ubiquiti Ubiquiti Networks the Ubiquiti U logo the Ubiquiti beam logo and mFi are trademarks or registered trademarks of Ubiquiti Networks Inc All other trademarks are the property of their respective owners PHRR040414 ...