Ubiquiti locoM Series Manual Download Page 1

29/01/22, 13:44

NanoStationM/locoM Series Quick Start Guide

https://dl.ui.com/qsg/NanoStationM_NanoStationlocoM/NanoStationM_NanoStationlocoM_EN.html

1/16

NanoStation 

M2/M3/M365/M5

Gravata

PoE (24V, 0,5A) com suporte

de montagem

Cabo de alimentação

NanoStationloco M2/M5

Gravata

PoE (24V, 0,5A) com suporte

de montagem

conteúdo do pacote

NSM2/NSM3/NSM365/NSM5

locoM2/locoM5

Guia de início rápido da série NanoStationM/locoM

Summary of Contents for locoM Series

Page 1: ...oM NanoStationM_NanoStationlocoM_EN html 1 16 NanoStation M2 M3 M365 M5 Gravata PoE 24V 0 5A com suporte de montagem Cabo de alimentação NanoStationloco M2 M5 Gravata PoE 24V 0 5A com suporte de montagem conteúdo do pacote NSM2 NSM3 NSM365 NSM5 locoM2 locoM5 Guia de início rápido da série NanoStationM locoM ...

Page 2: ...et com fio e deve ser aterrado através do terra CA do PoE We recommend that you protect your networks from harmful outdoor environments and destructive ESD events with industrial grade shielded Ethernet cable from Ubiquiti For more details visit ui com toughcable Surge protection should be used for all outdoor installations We recommend that you use two Ethernet Surge Protectors model ETH SP one n...

Page 3: ... locoM Series Quick Start Guide https dl ui com qsg NanoStationM_NanoStationlocoM NanoStationM_NanoStationlocoM_EN html 3 16 Hardware Overview NSM2 NSM3 NSM365 NSM5 locoM2 locoM5 Guia de início rápido da série NanoStationM locoM ...

Page 4: ...Quick Start Guide https dl ui com qsg NanoStationM_NanoStationlocoM NanoStationM_NanoStationlocoM_EN html 4 16 Power LED The LED will light green when the device is connected to a power source Guia de início rápido da série NanoStationM locoM ...

Page 5: ... wireless signal strength LEDs on the Advanced tab under Signal LED Thresholds The default values are shown below NanoStationM2 M3 M5 only This 10 100 Ethernet port is used for bridging and supports software configurable PoE passthrough Note To use PoE passthrough on the Secondary port a 24V 1A PoE adapter is required This 10 100 Ethernet port is used to connect the power and should be connected t...

Page 6: ...ht green when the device is connected to a power source The LED will light steady green when an active Ethernet connection is made to the Main LAN port and flash when there is activity In airOS you can modify the threshold values for the wireless signal strength LEDs on the Advanced tab under Signal LED Thresholds The default values are shown below Guia de início rápido da série NanoStationM locoM...

Page 7: ...d for future use This 10 100 Ethernet port is used to connect the power and should be connected to the LAN and DHCP server To reset to factory defaults press and hold the Reset button for more than 10 seconds while the device is powered on Alternatively the device may be reset remotely via a Reset button located on the bottom of the PoE adapter Installation 1 2 Guia de início rápido da série NanoS...

Page 8: ... 01 22 13 44 NanoStationM locoM Series Quick Start Guide https dl ui com qsg NanoStationM_NanoStationlocoM NanoStationM_NanoStationlocoM_EN html 8 16 3 4 Guia de início rápido da série NanoStationM locoM ...

Page 9: ...9 01 22 13 44 NanoStationM locoM Series Quick Start Guide https dl ui com qsg NanoStationM_NanoStationlocoM NanoStationM_NanoStationlocoM_EN html 9 16 5 Guia de início rápido da série NanoStationM locoM ...

Page 10: ...EN html 10 16 6 Connecting Power WARNING The switch port must comply with the power specifications listed in this Quick Start Guide OR Optional Accessing airOS Verify connectivity in the airOS Configuration Interface 1 Make sure that your host system is connected via Ethernet to the device Guia de início rápido da série NanoStationM locoM ...

Page 11: ...nt System Setup using the UNMS app requires the U Installer sold separately Installer Compliance Responsibility Devices must be professionally installed and it is the professional installer s responsibility to make sure the device is operated within local country regulatory requirements The Antenna Gain and Output Power fields are provided to the professional installer to assist in meeting regulat...

Page 12: ...5850 NanoStationlocoM2 M5 M9 Dimensions locoM9 164 x 72 x 199 mm 6 46 x 2 83 x 7 83 locoM2 locoM5 163 x 31 x 80 mm 6 42 x 1 22 x 3 15 Weight locoM9 0 9 kg 31 75 oz locoM2 locoM5 0 18 kg 6 35 oz Gain locoM9 locoM2 8 dBi locoM5 13 dBi Networking Interface 1 10 100 Ethernet Port Max Power Consumption locoM9 6 5W locoM2 locoM5 5 5W Power Supply 24V 0 5A PoE Adapter Included Power Method Passive PoE Pa...

Page 13: ...peration damage to the equipment or pose a fire hazard if the limitations are not followed 2 There are no operator serviceable parts inside this equipment Service should be provided only by a qualified service technician 3 This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet a Do not substitute the powe...

Page 14: ...not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operations of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense This radio transmitter has been approved by FCC ISED Canada CAN ICES 3 A NMB 3 A This device complies ...

Page 15: ...ment non contrôlé Lors de l installation et de la mise en fonctionnement de l équipement assurez vous qu il y ait une distance minimale de 20 cm entre l élément rayonnant et vous Cet émetteur ne doit être installé à proximité d aucune autre antenne ni d aucun autre émetteur et ne doit être utilisé conjointement à aucun autre de ces appareils Australia and New Zealand Warning This equipment is comp...

Page 16: ...o está restrito ao uso interno somente quando operando na faixa de frequência de 5150 5350 MHz em todos os estados membros Nota A operação na banda de frequência de 5 8 GHz é proibida nos estados membros da BFWA Outros países listados podem usar a banda de frequência de 5 8 GHz Declaração de Conformidade WEEE Declaração de conformidade Recursos online 2022 Ubiquiti Inc Todos os direitos reservados...

Reviews: