background image

NanoStation loco

Zip Tie

Package Contents

Installation Requirements

Shielded Category 5 (or above) cabling with drain wire should be used for all

outdoor wired Ethernet connections and should be grounded through the AC

ground of the PoE.
We recommend that you protect your networks from harmful outdoor

environments and destructive ESD events with industrial-grade, shielded Ethernet

cable from Ubiquiti. For more details, visit 

ui.com/toughcable

Surge protection should be used for all outdoor installations. We recommend that

you use two Ethernet Surge Protectors, model ETH-SP, one near the NanoStation

loco and the other at the entry point to the building. The ETH-SP will absorb

power surges and safely discharge them into the ground.

Loco5AC Quick Start Guide

Summary of Contents for Loco5AC-US

Page 1: ...s from harmful outdoor environments and destructive ESD events with industrial grade shielded Ethernet cable from Ubiquiti For more details visit ui com toughcable Surge protection should be used for...

Page 2: ...wer LED Ethernet Port Diagram Showing Use of Ethernet Surge Protectors Hardware Overview Port View The Power LED will light blue when the device is connected to a power source Loco5AC Quick Start Guid...

Page 3: ...nnect the power and should be connected to the LAN and DHCP server To reset to factory defaults press and hold the Reset button for more than 10 seconds while the device is powered on Hardware Install...

Page 4: ...2 3 Loco5AC Quick Start Guide...

Page 5: ...Connecting Power WARNING The switch port must comply with the power specifications listed in this Specifications Accessing airOS via Wi Fi Loco5AC Quick Start Guide...

Page 6: ...the Terms of Use to use the product Click Continue 4 Create a username and password Confirm your new password and then click Save The airOS Configuration Interface will appear allowing you to customiz...

Page 7: ...Operating Temperature 40 to 70 C 40 to 158 F Operating Humidity 5 to 95 Noncondensing Certifications CE FCC IC Not included Recommended PoE Adapter POE 24 12W G Operating Frequency MHz Worldwide 5150...

Page 8: ...This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation This equipment has been tested and fou...

Page 9: ...re limits set forth for an uncontrolled environment This equipment should be installed and operated with minimum distance 25 cm between the radiator and your body This transmitter must not be co locat...

Page 10: ...er limit per ETSI regulations The following apply to products that operate in the 5 GHz frequency range Note This device is restricted to indoor use only when operating in the 5150 5350 MHz frequency...

Reviews: