UAV-1001626-001 Rev F
ECCN 7A994
Page
26 | 30
13 Environmental Qualification Forms
Nomenclature
ping20Si ADS-B Mode S transponder
Part No: UAV-1000706-001
TSO-C199 Class A Device
Manufacturer
uAvionix Inc
Address
380 Portage Ave, Palo Alto, CA 94306
Conditions
DO-160G
Section
Description of Conducted Tests
Temperature and Altitude
4.0
Equipment tested to Category B2
Low temperature ground
survival
4.5.1
-55°C
Low Temperature Short-Time
Operating
4.5.1
-45°C
Low Temperature Operating
4.5.2
-45°C
High Temperature Operating
4.5.4
+80°C / +55°C*
High Temperature Short-Time
Operating
4.5.3
+80°C / +55°C*
High Temperature Ground
Survival
4.5.3
+85°C / +55°C*
Loss of Cooling
4.5.5
Cooling air not required (+70°C operating without
cooling)
Altitude
4.6.1
35,000feet
Decompression
4.6.2
Equipment identified as Category B2 – no test
Overpressure
4.6.3
Equipment identified as Category B2 – no test
Temperature Variation
5.0
Equipment tested to Category B2
Humidity
6.0
Equipment tested to Category B2
Operation Shocks
7.2
Equipment tested to Category B
Crash Safety
7.3
Equipment tested to Category B type 5
Vibration
8.0
Aircraft zone 2: type 3, 4, 5 to Category S level M,
type 1 (Helicopters) to Category U level G
Explosion
9.0
Equipment identified as Category X – no test
Waterproofness
10.0
Equipment identified as Category X – no test
Fluids Susceptibility
11.0
Equipment identified as Category X – no test
Sand and Dust
12.0
Equipment identified as Category X – no test
Fungus
13.0
Equipment identified as Category X – no test
Salt Spray
14.0
Equipment identified as Category X – no test
Magnetic Field
15.0
Equipment identified as Category Z
Power Input
16.0
Equipment identified as Category ZX
Voltage Spike
17.0
Equipment identified as Category B
AF Conducted Susceptibility
18.0
Equipment identified as Category B
Induced Signal Susceptibility
19.0
Equipment identified as Category AC
RF Susceptibility
20.0
Equipment identified as Category TT
RF Emissions
21.0
Equipment identified as Category B
Lightening Induced Transient
Susceptibility
22.0
Equipment identified as Category XXXX – no test
Lightening Direct Effects
23.0
Equipment identified as Category X – no test
Icing
24.0
Equipment identified as Category X – no test
Electrostatic Discharge
25.0
Equipment identified as Category X – no test
Fire, Flammability
26.0
Equipment identified as Category C
*based on max. operating temperature with battery pack.