14 Troubleshooting
The following steps are to aid in identifying installation or unit performance
related issues:
Table 8 - Troubleshooting
Issue
.
Possible Reason
Power
Unit does not power-on
.
Check associated breakers
.
Ensure aircraft battery is greater than 10 VDC
.
Check wiring and pinouts
.
Unit will not shut off, even if power is
removed
.
Ensure no pitot or static blockage or line kinks are present
(locking pressure and airspeed indication over 40 knots)
.
Stabilization
Unit will not stabilize and aligning
annunciator remains on
.
Return to factory for service if unit does not align within 3
minutes of power-on
.
DG drifts more than 30 degrees per
hour
.
Make sure you are running the newest software
.
Complete Gyro Cal
Battery
Battery indication shows FAIL
.
Contact uAvionix support
.
Trim
Roll, Pitch or Slip show small but
constant error
.
Ensure unit is level in panel (using a bubble level or similar)
Set trim adjustment in Installation menu. See Installation
Manual for instructions
.
Airspeed or Altitude shows small but
constant error
.
Set trim adjustment in Installation menu. See Installation
Manual for instructions
.
Interface
GPS information is expected but does
not show up in data overlays
.
Check GPS input is configured to match the connected GPS
serial data type and speed
.
Set direction indication to GPS TRK
.
“NO DATA” is shown
.
Check interface cables and pinouts
.
“NO GPS” is shown
.
Check GPS input is configured to match the connected GPS
serial data type and speed
.
Alerts
Audio alerts not heard over the audio
system
Check wiring and ensure alerts are enabled in the Setup
menu
.
Ensure unswitched input is available on the audio panel
.
Verify volume setting is sufficiently high in the Setup menu
.
Nuisance alerts are generated
.
Ensure alerting limits are configured as desired in the Setup
menu
.
Disable any undesired alerting features in the Setup Menus.