INSTALLATION INSTRUCTIONS
1. Make sure electrical supply is off at circuit breaker before starting luminaire installation or
servicing luminaire.
2. Thread luminaire onto junction box or other mounting device (by others) using thread sealant.
3. Attach luminaire leads to line in leads observing polarity, black to black, white to white and
green to ground using UL listed wire connectors (by others).
4. Attach junction box cover with luminaire to junction box (by others). Make sure not
to pinch wires that may be sandwiched between cover and box.
5. Coat exposed luminaire threads with thread sealant to keep moisture from entering
junction box or other mounting device.
6. Install lamp.
7. Install shade and lens and tighten screws evenly.
8. Coat all exposed screws with silicone grease.
9. Supply power to the luminaire and check for proper operation.
LAMP INSTALLATION/REPLACEMENT:
CAUTION: Do not exceed maximum wattage marked on luminaire label.
1. To prevent electrical shock, disconnect from electrical supply before service.
2. Loosen screws from shade.
3. Remove shade and lens to expose lamp.
4. Replace lamp with correct wattage and type marked on fixture label.
5. Re-install shade and lens and tighten screws evenly.
VISTA PROFESSIONAL OUTDOOR LIGHTING Division of U.S.T.E. Inc. Website: www.vistapro.com
1625 Surveyor Avenue, Simi Valley, CA 93063 (805) 527-0987 FAX: (805) 527-6830 (800) 766-8478