background image

 

http://u-prox.com 

22

 

 

Installation sequence 

1. 

Before  installation  remove  old  mortise  lock  and  escutcheons,  mark  and  drill 
holes  and  mortises  in  the  door  according  to  the  lock  installation  manual  and 
template, supplied with Smart Handle 

2. 

Prepare and install the mate part of the mortise lock 

3. 

If  door  contact  will  be  used  adjust  Request-To-Exit  micro  switch  according 
paragraph "

Request-To-Exit contact connection

4. 

Drill the holes in the doorpost for magnet and in the door for the magnetic door 
contact in the place, marked on the Fig. 8 below (optionally). 

5. 

Install  the  mortise  lock  and  fix  it  with  screws  according  to  the  mortise  lock 
installation instruction 

6. 

Install the outer escutcheon 1 and run connection wire 3 through the prepared 
for it opening (see Fig.10 a and b) 

7. 

Connect  magnetic  door  contact  to  the  DC  terminal  on  the  Battery  Holder  PCB 
(optionally) 

8. 

Connect controller wiring to the Battery Holder PCB  

9. 

Install  inner  escutcheon  11.  Take  care  that  rectangle  spindle  10  fell  into 
corresponding holes in the mortise lock and outer escutcheon precisely 

10.  Fix inner 11 and outer 1 escutcheons with screws 13 

11.  Insert  the  cylinder  16  (if  used)  and  secure  it  with  cylinder  retainer  pin  9, 

ensuring  pin  is  flush  with  front  plate  (according  to  mortise  lock  installation 
manual) 

12.  Install cover plate 8 and secure with screws provided to lock body 

13.  Place  the  batteries  into  the  battery  holder  18  following  the  polarity  marked 

below in this document, see Fig 13. 

14.  Put on the cover 12 of the inner escutcheon and fix it with screw 17, rotating it 

counterclockwise (unscrew) 

15.  Place the inner handle 14 on the rectangle 10 and fix it with screw 15 

16.  Add  the  panel  to  the  access  control  system  database  according  to  the  access 

control system manual  

17.  Download panel from the access control system according to the access control 

system manual 

18.  Panel is ready to operation 

Warning!!!  The  dividing  washer  needs  to  be  removed  from  3572  lock  to  allow 
the spindle to go through the lock. 

Warning!!!  If  the  door  contact  is  connected  and  Request-To-Exit  micro  switch 
hasn't  been  installed  any  opening  the  door  with  the  inner  handle  generates  an 
event FORCED ENTRY. 

Summary of Contents for IP500

Page 1: ...1 006 Wireless access control panel U Prox IP500 Smart Handle Installation and programming manual...

Page 2: ...the panel the pins and the mode of work are described in the Description section Order of installation adjustment of external devices and panel configuration are described in Working with the device s...

Page 3: ...1 Free Pass Mode 11 Blocking mode 12 RF ID properties cards 12 The communicator 12 Wireless lock system architecture 14 Wireless lock system deployment 15 Server addresses automatic configuration for...

Page 4: ...input for door position supervision The panel can work offline or as part of the network To add it to access control network U Prox IC L control panel used U Prox IC L panel communicates with U Prox...

Page 5: ...927 5 MHz o Guaranteed range 6 20 m o U Prox HE and U Prox HW repeaters for range extension Door contact input Request to exit on inner door handle Adjusted with U Prox IP software Real time clock No...

Page 6: ...d control has two passageways and the door having single sided reader only one passageway Access point which consists of two passageways is called double sided and the point of access which consists o...

Page 7: ...ss are indicated when setting user access rights Depending on modification control panel stores up to 250 time zones 250 week schedules can be combined from these time zones Moreover control panel can...

Page 8: ...utcheon 2 RF ID reader 3 Light emitting diode 4 Card presence Detector 5 Locking Cylinder 6 Outer handle 7 Door contact optional 8 Mortise lock 9 Cover plate 10 Inner escutcheon 11 Inner handle Fig 1a...

Page 9: ...diode 4 Card presence Detector 5 Locking Cylinder 6 Outer handle 7 Door contact optional 8 Mortise lock 9 Cover plate 10 Inner escutcheon 11 Inner handle Fig 1 U Prox IP500 panel installed on the door...

Page 10: ...sounds within range of the infrared sensor obstacle is more than a minute Control panel also sent event Reader sensor trouble Panel operation The panels supplied unloaded with factory settings below...

Page 11: ...count is exhausted for the temporary card visitor Alarm Mode Depending on the programmed functions Access point goes into mode Alarm in case of unauthorized passage Door Forced Open opening of panel...

Page 12: ...ters event Alarm cancelled and puts the door to Normal mode If the card that has no right to cancel the Alarm is passed the door will remain in the same state Access denied Alarm Status event recorded...

Page 13: ...est signals repeated every 2 minutes Attention The delay of delivery of the operator command to U Prox IP500 Smart Handle may last up to 2 minutes i e the period of the test signal Panel provides encr...

Page 14: ...i e make decision about the access using data uploaded beforehand U Prox IC L control panel routes data from the allowed U Prox IP500 Smart Handle wireless panels via U Prox HE and U Prox HW repeaters...

Page 15: ...cols DHCP for instance allowed to provide the plug and play principle The mode of the automatic server address configuration in the panels eases the wireless lock system deployment significantly The d...

Page 16: ...access control system server about itself as a new device in the local network Despite it is broadcast announcement it is limited with one range local network and active network equipment That s why t...

Page 17: ...the local network Despite it is broadcast announcement it is limited with one range local network and active network equipment That s why the IP addresses of the U Prox IC L panel are to be set manual...

Page 18: ...tem database e Operator must upload U Prox IC L control panel after the U Prox IP500 Smart Handle panel added to the DB f Operator must upload U Prox IP500 Smart Handle panel after the adjustment it i...

Page 19: ...tcheon 2 Reader 3 Connection cable 4 Panel board 5 Door contact magnetic optional 6 Mortise lock and cover plate screws 7 Mortise lock 8 Cover plate 9 Cylinder retainer pin 10 Rectangle 11 Inner escut...

Page 20: ...n 2 Reader 3 Connection cable 4 Panel board 5 Door contact magnetic optional 6 Mortise lock and cover plate screws 7 Mortise lock 8 Cover plate 9 Cylinder retainer pin 10 Rectangle spindle 11 Inner es...

Page 21: ...ange handles position for installation on desired door side proceed A Outer escutcheon See Fig 9 1 Release stopper rotating it on 900 2 Alter handle position 3 Return stopper to initial position B Inn...

Page 22: ...10 fell into corresponding holes in the mortise lock and outer escutcheon precisely 10 Fix inner 11 and outer 1 escutcheons with screws 13 11 Insert the cylinder 16 if used and secure it with cylinde...

Page 23: ...prox com 23 Fig 10a Cable running model for Lockwood 3582 Mortise Lock 89 9 mm Fig 10b Cable running model for Lockwood 3572 Mortise Lock 64 mm Opening for cables and DC wire Opening for cables and D...

Page 24: ...ss point states without the door contact proper operation Panel generates the Entry occurred message on inner handle press when the door contact is absent To enable door contact set the Z1 zone as A d...

Page 25: ...Fig 13 Battery replacement Return to factory settings To Return to factory settings 1 De power control panel remove at least one battery 2 Press and hold FactSet button 3 Supply power to control panel...

Reviews: