background image

http://u-prox.com

 

 

Terminals 

Colour / № 

Name 

Function 

9-wire cable 

Red 

+12 V 

Connection to the power supply, connection of an 

external reader 

Black 

GND 

Connection to the power supply, connection of an 

external reader, common for input loops 

Yellow 

Z1 

 

Terminals for Loop 

Orange 

Z2 

Brown 

NC

 (normally closed) 

 
 

Relay contacts 

 

Blue 

NO

 (normally open) 

Grey 

С1

 

(общий) 

White 

D1

 (Data 1) 

 

Connection of an external reader 

 

Green 

D0

 (Data 0) 

USB connector 

USB Mini B 

USB connector 

Used for the initial configuration of the network 

settings 

  

Ethernet connector 

TX

Connecting Ethernet cable. 

 

Terminals are measured from LED indicators: 

 

 

Fig. 3

. Marking terminals 

TX

– 

RX

RX

– 

Sound and light panel  

 Yellow LED: 

 

Standby mode

 (periodic blinking): 

o

 

1 short pulse once per second

 - communication  - Working in notification 

mode, connection normal; 

o

 

2 short pulse once per second

 - communication - Working in the 

notification mode, 

no connection

 

 

frequent blinking

 - downloading data from the server 

 

uploading mode

o

 

LED is on for 5 seconds

 - the detection of removed top cover, uploading 

mode start  

o

 

frequent blinking

 - waiting in uploading mode (with removed top cover), 

this indication means that the attempt to upgrade the firmware failed 

o

 

6 short beeps - successful upgrade of firmware  

o

 

 2 short beeps - uploading mode exit 

 

short beeps 

(with shorted pins D0 and D1) 

– Factory reset .

 

 

 

Green LED 1 - 

Link 

(next to the jack Ethernet): 

 

On - Ethernet cable is OK 

 

Green LED 2 - 

Eth. Activity

 (next to connector USB) 

 

Frequent blinking - Data Exchange 

Summary of Contents for IP100

Page 1: ...1 031 Access Control Panel U Prox IP100 Installation and programming manual...

Page 2: ...djustment of external devices and panel configuration are described in Working with the device section Technical support To get warranty and technical support you can apply to authorized service cente...

Page 3: ...th the device 20 Connection procedure 20 Installation recommendations 21 Installing Panel 21 Connecting an external reader 22 Connecting Loop Control 22 Request to Exit button RTE 23 Door Contact 23 C...

Page 4: ...r or two readers double sided door Having a large amount of non volatile memory U Prox IP100 is an access control system that provides for access control in variable establishments in small offices as...

Page 5: ...rvised inputs Built in Request to Exit button One relay contact NO NC COM 1 A 24 V One USB port to configure the network settings for connection to the ACS server Port Ethernet 4 wire 10 100 Mbps Wi F...

Page 6: ...oor of this type is called double sided door A door with a reader on one side has only one Access point Entry point and it is called single sided door Direction of passage Passageway is a logical unit...

Page 7: ...exit or tries to enter somewhere from the area he have not enter System generates message GLOBAL ANTIPASSBACK Access Denied in case of global antipassback violation Door time If door sensor is open c...

Page 8: ...Description and operation Panel The look of the access control panel is shown in Fig 1 and 2 Fig 1 U Prox IP100 panel Fig 2 U Prox IP100 components 3 4 2 1 1 Panel enclosure 2 RTE 3 LED 4 Keypad 7 1 1...

Page 9: ...X 4 RX Sound and light panel Yellow LED Standby mode periodic blinking o 1 short pulse once per second communication Working in notification mode connection normal o 2 short pulse once per second comm...

Page 10: ...is is the main mode of the panel In this mode the panel grants or denies access to RF ID owners In Normal mode the readers blink red Passing after entering RF ID To pass through user enters contactles...

Page 11: ...e of people such as in the case of fire earthquake or in other emergency For this case the panel has Free Pass mode In Free Pass Mode LED of reader flashes green and yellow The access point goes into...

Page 12: ...readers that have a built in keyboard Enter PIN code with the reader s keypad and press key Always enter PIN code AFTER the card pass If PIN code is correct panel unlocks access point and grants acces...

Page 13: ...is in Alarm Mode impulse the output is activated for the programmed time trigger mode on the first event the output is activated on the following is off etc continuous The communicator U Prox IP100 p...

Page 14: ...ra protection using VPN technology is recommend To provide backup communication channels use routers with two dissimilar channels of access to the Internet Working with multiple Wi Fi access points su...

Page 15: ...nsion of reserved IP if DHCP 5 Determine accessibility of ACS server and U Prox IC A control panel IP or DNS name 6 Periodic sending test signals 7 If there is send the events Waiting for server comma...

Page 16: ...ver and U Prox IC A control panel IP or DNS name 7 Periodic sending of test signals 8 If there is send the events Waiting for server commands 9 Failure transition to the second IP address of specified...

Page 17: ...rded into the DB Panel becomes associated to the certain access control system server eliminating panel control capture with another system Return panel to the factory settings to eliminate the panel...

Page 18: ...tion unspecified is assigned when registering a new employee or after the system operator command location reset of person is fixed by U Prox IC A With the use of global antipassback it is possible to...

Page 19: ...C F18 IP adjusting Only control panels with double sided doors entrance and exit on presentation of ID can be involved in global antipassback In configuraion server address 1 has to be the ACS server...

Page 20: ...s from sensors buttons 7 Run the cable lead Ethernet if necessary 8 Run the wire commutation of power supply lock reader inputs of the panel with the loops in accordance with the sections below recomm...

Page 21: ...st 20 cm from panel to eliminate the effect of double reading Installing Panel Loosen the screw at the bottom of panel Remove the upper lid remove the back plate Using the back plate of the panel as a...

Page 22: ...nsumption more than 100 mA supply the voltage to it from the separate source Connecting Loop Control Panel has two inputs for connecting the loops supervised with end of line resistors Each input func...

Page 23: ...Fig 15 Fig 15 Connection of RTE button Z1 input function assigned as follows Z1 RTE of access point A The use of button of the electric lock to open access point or allow access button on the turnsti...

Page 24: ...combined loop connection to Z1 terminals is on the Fig 17 Fig 17 Connecting combined loop Z1 input function assigned as follows Z1 Combined door contact and RTE of access point A Any of two inputs ca...

Page 25: ...or turns on and off any optional hardware with this output The example of actuator connection is on the Fig 19 The first is powering the lock and second by depowering Fig 19 Connecting locks When usi...

Page 26: ...erver Panel communicator operates in notification mode If there is event passage input violation data transmission to ACS server is initiated Panel provides protection against arbitrary interference d...

Page 27: ...nternet 2 optional o IP address of the DNS Server 1 if data transfer of the domain name is used o IP address of the DNS Server 2 optional if data transfer of the domain name is used Setting communicat...

Page 28: ...P address of the gateway router to the Internet 2 optional o IP address of the DNS server 1 if a data transfer of the domain name o IP address of the DNS Server 2 optional if you are using a data on t...

Page 29: ...refer to the software manual 4 Set up device with ACS software a Door settings Single sided or Double sided door operation of Antipassback Time of PIN entering or off b Access points settings no of re...

Page 30: ...qual to 0 zero 5 Upload write the new configuration to the panel The controller will restart with factory settings Switching to programming mode To put panel in programming mode do the following 1 Do...

Reviews: