13
a.
Panel sends data packages announcing access control system
server about itself as a new device in the local network
Despite it is broadcast announcement, it is limited with single
range local network and active network equipment. That’s why
the IP addresses of the access control system server are to be
set manually for networks with sophisticated topology.
b.
The system will warn operator after the receiving of the data
package from the new panel. Than operator must add panel to
the system database (DB).
c.
After the panel added to the DB it receives the answer from the
access control system server. The address of the access control
system server recorded into the control panel and it stops to
broadcast.
d.
Operator has to download panel after its adjustment recorded into
the DB. Panel will be connected to the certain access control
system server, eliminating panel control capture with another
system.
Return panel to the factory settings to eliminate the panel
connection to the system
e.
In the case of access control system IP address change panel
will initiate the automatic configuration routine, but the data
exchange will be possible with previously connected system only.
U-Prox IC L addresses automatic configuration for repeaters
1.
Repeater checks for DHCP mode ON (repeater address 0.0.0.0) or static
IP
2.
If DHCP mode is ON, the dynamic IP address obtain routine will start
3.
The repeater automatic configuration mode starts if the U-Prox IC L panel
IP address (IP or DNS name) is not set:
a.
Repeater sends data packages announcing U-Prox IC L panel
about itself as a new device in the local network
Despite it is broadcast announcement, it is limited with single
range local network and active network equipment. That’s why
the IP addresses of the U-Prox IC L panel are to be set manually
for networks with sophisticated topology.
b.
The system will warn operator after the receiving of the data
package from the new repeater through the U-Prox IC L panel.
Than operator must add repeater to the system database (DB).
c.
Operator has to download U-Prox IC L panel after repeater
recorded into the DB.