background image

http://u-prox.com

 

 

11

 

4. 

Determine accessibility of U-Prox IC L (IP or DNS name) 

5. 

Periodic sending of test signals 

6. 

If there is, send the events. Waiting for server commands. 

7. 

Failure - transition to the second specified IP address of router. 

Wireless lock system architecture 

The  architecture  of  the  wireless  locks system  has  definitely  hierarchic  structure.  All 
U-Prox IP500  control  panels  operate  in  the  automatic  mode,  i.e.  make  decision 
about the access using data downloaded beforehand. 

U-Prox IP control panel routes data from the allowed U-Prox IP500 wireless panels 
via U-Prox HE and U-Prox HW repeaters. The U-Prox access control system server, 
U-Prox IC L, U-Prox HE and U-Prox HW communicate each other via the computer 
network.  The  U-Prox  IC  L,  U-Prox  HE  and  U-Prox  HW communicate  to  the  U-Prox 
IP500 wireless repeaters via the ISM band radio. 

 

Fig. 5. Wireless lock system architecture 

Wireless lock system deployment 

The use of the existing computer network infrastructure, standard network protocols 
(DHCP  for  instance)  allowed  to  provide  the  “plug-and-play”  principle.  The  mode  of 

Summary of Contents for HE

Page 1: ...1 003 Wireless subsystem repeater U Prox HE Installation and programming manual...

Page 2: ...ion adjustment of external devices and repeater configuration are described in Working with the device section Technical support To get warranty and technical support you can apply to authorized servi...

Page 3: ...ock system architecture 11 Wireless lock system deployment 11 Server addresses automatic configuration for U Prox IC L 12 U Prox IC L addresses automatic configuration for repeaters 13 U Prox IP500 au...

Page 4: ...m for U Prox IP500 control panel network range extension Summary Power o External power supply 12V Current consumption max 150 mA 12V Maximum voltage ripple 500 ma peak to peak o Micro USB B o Modific...

Page 5: ...access control repeater or its part door supervision devices like door contact RTE button etc and door locking device For instance the turnstile with two way passes has two Access points one for entr...

Page 6: ...repeater is shown in Fig 1 a and b Figure 1a U Prox HE repeater modification 1 Figure 2b U Prox HE repeater modification 2 1 The Enclosure 2 Ethernet port 3 Micro USB B port 4 Reset button 5 Connector...

Page 7: ...U Prox HE board modification 1 Figure 2a U Prox HE board modification 2 Assignment of the repeater contacts and indication Contact Name Purpose 12V 12V External 12V power supply connection GND GND US...

Page 8: ...tings use the command from the U Prox software or with the routine described in Service Maintenance section In the Normal mode repeater processes information from U Prox IP500 panels received through...

Page 9: ...Fig 3 Mixed type Ethernet Wi Fi local network connection example Where U Prox HW repeater designed to expand the scope of the ISM band wireless interface To connect to the network use Wi Fi wireless...

Page 10: ...of the repeater 2 Update of IP status of address announcement and extension of reserved IP if DHCP 3 Determine accessibility of U Prox IC L IP or DNS name 4 Periodic sending of test signals 5 If there...

Page 11: ...the access using data downloaded beforehand U Prox IP control panel routes data from the allowed U Prox IP500 wireless panels via U Prox HE and U Prox HW repeaters The U Prox access control system se...

Page 12: ...tion 3 U Prox IP500 wireless repeaters connection Fig 6 Wireless lock system deployment The algorithms for operation on each step described below Server addresses automatic configuration for U Prox IC...

Page 13: ...to eliminate the panel connection to the system e In the case of access control system IP address change panel will initiate the automatic configuration routine but the data exchange will be possible...

Page 14: ...the power up 2 If U Prox IP500 does not connected to anyone U Prox IC L the automatic configuration mode will start a Panel will broadcast data packages announcing itself as a new panel b Data packag...

Page 15: ...are the place for installation mark and drill mounting holes see Mount recommendat ions 3 Perform Ethernet wiring 4 Perform power wiring if it is necessary 5 Install and fix the enclosure cover with s...

Page 16: ...er operates in automatic mode It routes event message data from the allowed U Prox IP500 wireless panels to U Prox IC L panels connected to the Ethernet computer network after the configuration data d...

Page 17: ...te blue 6 green 6 yellow 7 white brown 7 white brown 8 brown 8 brown To adjust repeater communicator perform Adjust repeater network settings don t adjust when use DHCP o IP address o Subnet mask o Ga...

Page 18: ...5 Download repeater from U Prox IP software Service maintenance Return to factory settings To Return to factory settings 1 De power repeater 2 Press and hold FUNC button 3 Supply power to repeater 4 W...

Page 19: ...http u prox com 19 Reference for device installation modification 2...