background image

USER GUIDE

u-line.com

Control Operation-Service

USER GUIDE

 Control Operation - Service 5

u-line.com

SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • 

SERVICE

MODEL LIST

PROGRAMMING THE UNIT TO CORRECT 
MODEL NUMBER
1.

Disconnect the unit from power source.

2.

Push and hold the U-Line button.

3.

While still holding the U-Line button, plug the 

unit into the appropriate power source.

4.

When the flashing digits appear (3-5 seconds), 

use the up and down arrow buttons to select the 
appropriate model number*.

*(See Above “Model List”)

5.

Press the light bulb button once. 

6.  

The display will blink, and then will appear as the 
programmed display. 

     1000

    MODEL 

INDICATOR

2000 (120V)     MODEL 

INDICATOR

2000 (230V)     MODEL 

INDICATOR

1215R

07

2218R

05

2245R

55

1215WC

12

2218RGL

04

2245DC

54

1224BEV

13

2218WC

06

2245WC

56

1224DWR

08

2224BEV

00

2260DC

50

1224R

14

2224R

02

2260R

52

1224RF

09

2224RGL

01

2260RDC

51

1224RSOD

10

2224WC

03

2260WC

53

1224WC

15

2224ZWC

59

2260ZWC

58

CLR1215

18

ADA24R

17

CO1224F

19

1224FZR

11

or

40

Summary of Contents for UHFZ124-SS01B

Page 1: ...USER GUIDE SERVICE MANUAL 1 Class UHFZ124 24 Convertible Freezer ...

Page 2: ...ille Installation Door Swing Door Adjust Interior Adjustments Maintenance Free Standing Kit Cleaning Cleaning Condenser Extended Non Use Operating Instructions First Use Control Operation Airflow and Product Loading Service Troubleshooting Product Liability Warranty Claims Parts Ordering Replacement Parts System Diagnosis Guide Compressor Specifications Troubleshooting Extended Control Operation S...

Page 3: ...elect products are available worldwide PRODUCT INFORMATION Looking for additional information on your product User Guides Spec Sheets CAD Drawings Compliance Documentation and Product Warranty information are all available for reference and download at u line com PROPERTY DAMAGE INJURY CONCERNS In the unlikely event property damage or personal injury is suspected related to a U Line product please...

Page 4: ...r or moderate personal injury property or equipment damage This unit contains R600a Isobutane which is a flammable hydrocarbon It is safe for regular use Do not use sharp objects to expedite defrosting Do not service without consulting the R600a specifications section included in the User Guide Do not damage the refrigerant circuit Service must be done by factory authorized service personnel Any p...

Page 5: ...in place so children may not easily climb inside If the unit is being removed from service for disposal check and obey all federal state and local regulations regarding the disposal and recycling of refrigeration appliances and follow these steps completely 1 Remove all consumable contents from the unit 2 Unplug the electrical cord from its socket 3 Remove the door s drawer s DANGER 5 ...

Page 6: ...emperatures may reduce the unit s ability to reach low temperatures and or reduce ice production on applicable models For best performance keep the unit out of direct sunlight and away from heat generating equipment In climates where high humidity and dew points are present condensation may appear on outside surfaces This is considered normal The condensation will evaporate when the humidity drops...

Page 7: ...the unit Always keep your working area dry NOTICE Electrical installation must observe all state and local codes This unit requires connection to a grounded three prong polarized receptacle that has been placed by a qualified electrician The unit requires a grounded and polarized 115 VAC 60 Hz 15A power supply normal household current An individual properly grounded branch circuit or circuit break...

Page 8: ...ction in the rear CAUTION Unit can NOT be installed behind a closed cabinet door CUTOUT DIMENSIONS PRODUCT DIMENSIONS REAR FRONT TOP SIDE 4 102 mm 7 178 mm 24 610 mm 24 1 4 616 mm 34 1 8 867 mm to 35 1 8 892 mm Preferred location for electrical outlet is in adjacent cabinet 5 8 16 mm Power Cord 6 ft 183 cm 6 3 8 162 mm 3 7 8 98 mm 23 15 16 608 mm 3 9 16 91 mm 34 1 8 to 35 1 8 867 mm to 892 mm 28 7...

Page 9: ...ced according to each unit s electrical specifications requirements Side by Side Installation with Bracket 1 Slide both units out so screws on top of units are easily accessible 2 Remove screws as shown below 3 Place bracket over holes and attach to unit with two screws removed in step 2 using a T 25 Torx driver Tighten screws fully 4 Gently push units into position Be careful not to entangle the ...

Page 10: ...over holes and attach to unit with two screws removed in step 2 using a T 25 Torx driver Tighten screws fully 4 Gently push unit into position Be careful not to entangle the electrical cord or water line if applicable 5 Check to be sure the unit is level from front to back and side to side Make any necessary adjustments The unit s top surface should be approximately 1 8 3 mm below the countertop 6...

Page 11: ...an opening s rear height Shorten the unit height in the front by adjusting the front legs This allows the unit to be gently tipped into the opening Readjust the front legs to level the unit after it is correctly positioned in the opening INSTALLATION 1 Plug in the power electrical cord 2 Gently push the unit into position Be careful not to entangle the cord or water and drain lines if applicable 3...

Page 12: ... are SHARP and can be easily damaged Removing the grille 1 Disconnect power to the unit 2 Loosen the two screws 1 3 Remove grille 2 from unit Installing the grille 1 Align cabinet and grille holes and secure but do not over tighten grille screws 1 Note When installing next to a 15 wide U Line product use the supplied spacers behind the grille The 24 grille will now be on the same plane as the 15 g...

Page 13: ...ing Units have a zero clearance for the door to open 90 when installed adjacent to cabinets Stainless Steel models require 2 1 8 54 mm door clearance to accommodate the handle if installed next to a wall Wall 90 Door Swing 2 1 8 Min 54 mm 13 ...

Page 14: ... Loosen do not remove top and bottom hinge screws using a Torx T 25 screwdriver 3 Align door squarely with cabinet 4 Make sure gasket is firmly in contact with cabinet all the way around the door no gaps 5 Tighten bottom hinge screws 6 Tighten top hinge screws and replace hinge cover REVERSING THE DOOR Location of the unit may make it desirable to mount the door on the opposite side of the cabinet...

Page 15: ...e models there may be a nut behind one or both screws on either side Install bottom hinge Install two or three screws depending on model Replace nuts if used Install top hinge and door 1 Install hinge with longer straight edge aligned to outside edge of cabinet Do not tighten 2 Rotate door 180o and set on bottom hinge 3 Align edge of the hinge with the outer edge of the unit 4 Tighten three hinge ...

Page 16: ...nto a cabinet Available at u line com To install the kit 1 Remove grille see GRILLE INSTALLATION section 2 Place shell accessory over front and back of cabinet base aligning holes of shell accessory with the holes on the base Insert sheet metal screw in back of base 3 Align front hole wit hole in shell accessory hole in base and hole in grille Tighten screw 16 ...

Page 17: ... reflects actual temperature inside unit If the temperature displayed is different than selected the unit is progressing towards the selected temperature Time to reach set point varies based upon ambient temperature temperature of product loaded door openings etc U Line recommends allowing the unit to reach set point before loading Approximate time required empty unit when converting between refri...

Page 18: ...nd display will show the default set point for Refrigerator Freezer Enable Sabbath Mode Press and hold for 5 seconds and release The oF oC symbol will flash briefly after 5 seconds Interior light and display will go dark and remain so until user resets mode unit continues to operate Disable Sabbath Mode Press and release Display and interior light return to normal operation Showroom Mode Hold and ...

Page 19: ...ATING INSTRUCTIONS MAINTENANCE SERVICE Airflow and Product Loading NOTICE The unit requires proper airflow to perform at its highest efficiency Do not block the front grille internal fans or vents at any time or the unit will not perform as expected Do not install the unit behind a door 19 ...

Page 20: ...rack rails from the cabinet To reinstall 1 Align the left and right basket channels with the tracks in the cabinet Ensure an even track engagement on both sides by gently pushing the basket into the cabinet until it stops 2 Before reloading the basket ensure proper movement of the travel stops in the left and right track rails by pulling the basket out gently until it stops 3 Push the basket into ...

Page 21: ...less steel to become blurred Rust not cleaned up promptly can penetrate the surface of the stainless steel and complete removal of the rust may not be possible Integrated Models To clean integrated panels use household cleaner per the cabinet manufacturer s recommendation INTERIOR CLEANING Disconnect power to the unit Clean the interior and all removed components using a mild nonabrasive detergent...

Page 22: ...r sensitive flooring the unit must be removed from cabinetry To defrost 1 Disconnect power to the unit 2 Remove all products from the interior 3 Prop the door in an open position 2 in 50 mm minimum 4 Allow the frost to melt naturally 5 After the frost melts completely clean the interior and all removed components See INTERIOR CLEANING 6 When the interior is dry reconnect power and turn unit on 22 ...

Page 23: ...er when necessary Depending on environmental conditions more or less frequent cleaning may be necessary WARNING Disconnect electric power to the unit before cleaning the condenser NOTICE DO NOT use any type of cleaner on the condenser unit 1 Remove the grille 2 Clean the condenser coil using a using a soft brush with a combing action or vacuum cleaner 3 Install the grille Condenser 23 ...

Page 24: ...on the evaporator allow ice to thaw naturally 4 Clean and dry the interior of the unit Ensure all water has been removed from the unit 5 The door must remain open to prevent formation of mold and mildew Open door a minimum of 2 50 mm to provide the necessary ventilation WINTERIZATION If the unit will be exposed to temperatures of 40 F 5 C or less the steps above must be followed For questions rega...

Page 25: ...compressor makes a hum or pulsing sound that may be heard when it operates BEFORE CALLING FOR SERVICE TROUBLESHOOTING GUIDE ELECTROCUTION HAZARD Never attempt to repair or perform maintenance on the unit before disconnecting the main electrical power Troubleshooting What to check when problems occur NORMAL OPERATING SOUNDS IF SERVICE IS REQUIRED Troubleshooting Evaporator Refrigerant flowing throu...

Page 26: ...ing the testing period 6 After 24 hours check the temperature of the water If required adjust the temperature control in a small increment see CONTROL OPERATION Causes which affect the internal temperatures of the cabinet include Temperature setting Ambient temperature where installed Installation in direct sunlight or near a heat source The number of door openings and the time the door is open Th...

Page 27: ...ized to replace the part in question The part that caused the damage must be returned to U Line in its entirety The part must be clearly labeled with the serial number of the unit it was removed from the date and the servicer who removed the part If the service technician determines the damage is the result of installation issues water connection drain etc the consumer would be notified and the is...

Page 28: ...ting for warranty labor Units must be registered prior to warranty submittal Customers may register at www U Line com A proof of purchase is required We also accept the following information to update warranty New construction occupancy documents Closing paperwork Final billing Remodel Warranty parts will be shipped at no charge after U Line confirms warranty status Please provide the model serial...

Page 29: ...ET LOWER 80 54802 00 4 BASKET UPPER 80 54803 00 5 COMPRESSOR ELECTRICALS 80 54800 00 6 COMPRESSOR 80 54799 00 7 CONDENSER ASSY 80 54801 00 8 CONDENSER FAN BLADE 80 54798 00 9 CONDENSER FAN MOTOR 80 54797 00 10 DEFROST THERMOSTAT 80 54812 00 11 DISPLAY ASSEMBLY 80 55414 00 12 DOOR ASSEMBLY 80 55416 00 13 DOOR GASKET 80 55498 00 14 DRAIN PAN 80 54217 00 15 DRIER 80 54055 00 16 EVAPORATOR ASSY 80 548...

Page 30: ...rms warranty status Please provide the model serial number part number and part description Some parts will require color or voltage information If U Line requires the return of original parts we will inform you when the parts order is taken This requirement will be noted on your packing list A prepaid shipping label will be emailed to you Please enclose a copy of the parts packing list and be sur...

Page 31: ...perature Hot Warm Warm Extremely cold near inlet Outlet below room temperature Lower than normal Partial Restriction Somewhat lower than normal vacuum Warm near room temperature Very hot Top passes warm Lower passes cool near room temperature due to liquid Room temperature cool or colder Extremely cold near inlet Outlet below room temperature backing up Lower than normal Complete Restriction In de...

Page 32: ...n anti static wrist strap that is grounded to an electrical ground or grounded water pipe Handle circuit boards carefully and avoid touching components To measure the start winding resistance measure across the C and S pins To measure the run winding resistance measure across the C and R pins Also check S to R and you should get the sum of the run and start windings To ensure the windings are not ...

Page 33: ...9 2547 for assistance NORMAL OPERATING SOUNDS All models incorporate rigid foam insulated cabinets to provide high thermal efficiency and maximum sound reduction for its internal working components Despite this technology your model may make sounds that are unfamiliar Normal operating sounds may be more noticeable because of the unit s environment Hard surfaces such as cabinets wood vinyl or tiled...

Page 34: ...e Mode OHM thermistor Frost Buildup Inside Unit Door Ajar or Restricted from Closing Check door clearance to adjoining cabinetry Check distribution of product in unit Thermistor failure OHM thermistor Display Not Working Display unplugged Verify that both ends of the display wiring are firmly connected Display wiring broken or damaged Perform continuity test of wiring and replace as needed Interio...

Page 35: ...ce Plunger Switch Replace Main Board Replace Fuse Replace Power Cord Alert Customer Of Power Failure Is the Plunger Switch Operating Properly Inspect Customer UI and Data Cable Connect Test Display Cycle Power And Check For Operation No Voltage No Voltage Voltage Continuity Operating Not Operating No Continuity No Yes Voltage CAUTION Precautions must be taken while working with live electrical equ...

Page 36: ... alert and reset VIEWING ACTUAL TEMPERATURE In viewing temperature in these modes any offsets are taken into account This means that if you place a therm istor in a known temperature let s say ice water it may not read the 32 F that you would assume If the control offset was preset at 3 F while you placed the thermistor When the degree symbol is flashing the unit will allow the use of the control ...

Page 37: ...ether The display will flash and then toggle from set point to temperature in unit seconds The display will change units or ACCESS SERVICE MODE To access the service menu for this model remove the two screws that hold the display together Remove display circuit board Press and hold the far left button on the display circuit board Press and Hold USER GUIDE SAFETY INSTALLATION INTEGRATION OPERATING ...

Page 38: ...EFROST DURATION 0 TO 99 MINUTES The length of the defrost can be adjusted 0 to 99 minutes long The other defrost parameters still apply Lengthening a defrost may cause higher than normal temperatures in the refrigerator section USER GUIDE SAFETY INSTALLATION INTEGRATION OPERATIN 14 VIEW ERROR LOG A list of the errors in the order they occurred will scroll once on the display All errors are logged ...

Page 39: ...IME This will show the number of minutes the compressor has run in the prior cycle or current cycle if the compressor was running when service mode was entered 24 ACTIVATE DEFROST HARVEST Turns on the hot gas bypass valve allowing hot gas to circulate through the evaporator causing frost to melt 25 RESTORE FACTORY DEFAULTS Will restore all adjustable functions to their factory settings 26 SOFTWARE...

Page 40: ... flashing digits appear 3 5 seconds use the up and down arrow buttons to select the appropriate model number See Above Model List 5 Press the light bulb button once 6 The display will blink and then will appear as the programmed display 1000 MODEL INDICATOR 2000 120V MODEL INDICATOR 2000 230V MODEL INDICATOR 1215R 07 2218R 05 2245R 55 1215WC 12 2218RGL 04 2245DC 54 1224BEV 13 2218WC 06 2245WC 56 1...

Page 41: ... A 2218R N A N A N A N A N A Compressor Light Evaporator Fan Condenser Fan N A N A 2218RGL N A N A N A N A N A Compressor Light Evaporator Fan Condenser Fan N A N A 2218WC N A N A N A N A N A Compressor Light Evaporator Fan Condenser Fan N A N A 2224BEV N A N A N A N A N A Compressor Light Evaporator Fan Condenser Fan N A N A 2224R N A N A N A N A N A Compressor Light Evaporator Fan Condenser Fan ...

Page 42: ...tain the operating temperature within that zone Thermistor two Evaporator Located on the evaporator It is used for defrost THERMISTOR FAILURE Zone Thermistor If the zone thermistor in the unit fails the unit will continue to cool in a backup mode Self Preservation Mode to preserve the integrity of the contents The unit will otherwise operate normally USER GUIDE u line com Thermistors are used for ...

Page 43: ...2 hours of compressor runtime for 45 minutes If you have verified that the unit does not have an ambient air leak utilize the Control Operation Service section and adjust unit to defrost every 9 hours for 60 minutes Also adjust the 2 thermistor to 4 instead of 0 43 ...

Page 44: ...condensation that may have appeared on glass doors and shelves Note If the unit is set to sabbath mode the evaporator fan will no longer respond to the state of the door switch In order to operate efficiently the evaporator fan blade and vents should be unobstructed and free of any dust buildup Evaporator Fan Replacement Should the evaporator fan need to be replaced follow the steps below 1 Remove...

Page 45: ...rator cover vents and push air out at fan mounting location 15 Installation is the reverse of removal 16 Care must be taken to assure the bottom of the evaporator cover is reinstalled behind the front edge of the train trough 17 Use sealant gum to seal any openings at rear of unit before replacing rear cover 18 Reinstall unit taking care to level space and secure as found 45 ...

Page 46: ...od or other natural disasters The product must be installed operated and maintained in accordance with your product s User Guide The remedies described above for each warranty are the only ones that U Line will provide either under these warranties or under any warranty arising by operation of law U Line will not be responsible for any consequential or incidental damages arising from the breach of...

Reviews: