background image

®

The Built-In Undercounter Leader Since 1962

CLEAR ICE MODELS
CLEAR ICE COMBO MODELS
ICE COMBO MODELS

U-LINE.COM

CO1175

CO2175

CLR2160

CLRCO2175

INSTALL GUIDE

CO29

Summary of Contents for CLRCO2175

Page 1: ...The Built In Undercounter Leader Since 1962 CLEAR ICE MODELS CLEAR ICE COMBO MODELS ICE COMBO MODELS U LINE COM CO1175 CO2175 CLR2160 CLRCO2175 INSTALL GUIDE CO29...

Page 2: ...ty 6 Reversing the door 6 Self Closing Doors Door Alignment and Adjustment 8 Door Reversability 8 Reversing the door 8 Door Panel Installation Custom 1 4 Thick Door Panel Insert 10 Door Panel Preparat...

Page 3: ...Grounding Required Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected Never remove the round grounding prong from the plug and never use a two prong...

Page 4: ...nel Kit Part number U OL2175B black units U OL2175W white units A complete water hook up kit is also available for purchase from your dealer Order U Line Part No WATERHOOKUP Exterior Cleaning Black an...

Page 5: ...lations CLR2160 Series Follow the cut out drawing The 15 1 4 width allows 1 4 for ease in installation and removal of the unit 24 is the cabinet depth in most installations 8 24 Minimum 24 1 4 See Ele...

Page 6: ...34 1 8 15 15 Black and White Stainless Steel 23 3 16 3 7 8 23 1 8 3 15 16 Add 3 4 To Depth For Drain Line Clearance Add 3 4 To Depth For Drain Line Clearance CO1175 Series BLACK CO1175 23 1 4 34 1 8...

Page 7: ...ments The units are designed to operate between 50 F 10 C and 100 F 37 C High ambient temperatures 100 F 37 C or higher may reduce the unit s ability to reach low temperatures and may also reduce the...

Page 8: ...h black and white doors are field reversible Stainless steel models with glass doors without locks are field reversible Stainless steel models without glass doors must be ordered right or left hand hi...

Page 9: ...ure to only remove the two screws holding the actuator to the door Reinstall the actuator 4 on the opposite end of the door where the nameplate was removed 8 Install new nameplate where the actuator a...

Page 10: ...sets 3 Turn the door upside down and inspect the hinge plate mounting holes The plate has slotted mounting holes Loosen but do not remove the two hinge plate screws 1 4 If door edge opposite the hinge...

Page 11: ...r inserts as shown on the new bottom hinge 4 Remove existing bottom hinge Remove the existing bottom hinge three screws 2 Reinstall hinge to top opposite Install the hinge just removed from the bottom...

Page 12: ...tilting forward and lifting off bottom hinge pin 2 Pull door gasket out of groove top edge of door only Start in the middle and pull outward moving toward the edge This may take some force Model Width...

Page 13: ...lled in such a manner that the grille assembly can still be removed from the unit Screw Mount Recommended 1 Remove the grille from your unit by removing the two mounting screws See below 2 Lay the bac...

Page 14: ...ine Grill Overlay Installation 12 1 4 8 1 2 3 3 32 19 5 8 1 2 1 2 TYP 3X 5 16 TYP 2X 7 16 5 16 10 5 16 11 64 2 1 8 1 2 22 7 8 23 7 8 FULL R Grille Overlay Dimensions 24 Inch Models Grille Drawing 24 i...

Page 15: ...ine Grill Overlay Installation 13 1 4 4 5 32 3 3 32 10 5 8 1 2 1 2 TYP 3X 5 16 TYP 2X 15 32 275 5 29 32 11 64 2 1 8 1 2 13 7 8 14 7 8 FULL R Grille Overlay Dimensions 15 Inch Models Grille Drawing 15i...

Page 16: ...een placed by a qualified electrician The unit requires a grounded and polarized 115 VAC 60 Hz 15A power supply normal household current An individual properly grounded branch circuit or circuit break...

Page 17: ...er supply and disconnect electrical supply to unit prior to attempting installation 1 Turn off water supply and disconnect electrical supply to product prior to attempting installation 2 Locate the de...

Page 18: ...f necessary insulate drain line to prevent condensation 4 Test the drain system per the test procedure under Final Installation on page 17 WARNING Failure to connect water supply or drain line connect...

Page 19: ...ump we strongly recommend the use of the U Line P60 drain pump The U Line P60 drain pump is available through your dealer with complete installation instructions Final Installation IMPORTANT IMPORTANT...

Page 20: ...st plugged into the electrical outlet Test the drain system by pouring one gallon of water into the ice bin The water should drain freely and there should be no leakage All Models 3 Gently push the un...

Page 21: ...ution A The hinges should be self closing when the door is open approximately 8 If this is not the case make sure the closers at the bottom of the hinge pin are clean greased and installed correctly A...

Page 22: ...today The Milwaukee Wisconsin based family operated business provides continuity and vision from which innovations continue to be born Going forward U Line will continue offering best in class product...

Reviews: