Modular 3000 Series  

 

3060DC  

 

60 cm Drinks Cabinet

RIGHT PRODUCT. RIGHT PLACE. RIGHT TEMPERATURE. SINCE 1962.

Summary of Contents for 3060DC

Page 1: ...ER GUIDE SERVICE MANUAL SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE Modular 3000 Series 3060DC 60 cm Drinks Cabinet RIGHT PRODUCT RIGHT PLACE RIGHT TEMPERATURE SINCE 196...

Page 2: ...linth Installation Door Swing Door Stop Door Adjust Maintenance Cleaning Cleaning Condenser Extended Non Use Operating Instructions First Use Control Operation Sabbath Mode Airflow and Product Loading...

Page 3: ...ve the opportunity to ship to you PRODUCT INFORMATION Looking for additional information on your product User Guides Spec Sheets CAD Drawings Compliance Documentation and Product Warranty information...

Page 4: ...ughout this guide This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience or knowledge unless they have been giv...

Page 5: ...ver install or operate the unit behind closed doors Be sure front grille plinth strip base fascia is free of obstruction Obstructing free airflow can cause the unit to malfunction and will void the wa...

Page 6: ...reezer take off the doors and leave shelves in place so children may not easily climb inside If the unit is being removed from service for disposal check and obey all federal state and local regulatio...

Page 7: ...F 10 C and 90 F 32 C Higher ambient temperatures may reduce the unit s ability to reach low temperatures and or reduce ice production on applicable models For best performance keep the unit out of dir...

Page 8: ...area dry If the detachable type electric supply cord is damaged it must be replaced by an equivalent cord available from the manufacturer or its service agent NOTICE Electrical installation must obse...

Page 9: ...ening must be square and plumb front to back Although not required you may choose to increase the overall cutout width for ease of installation The Modular 3000 Series units are engineered with a vari...

Page 10: ...e com SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE Product Dimensions 3 5 8 to 4 5 8 92 mm to 118 mm 33 11 16 to 34 11 16 856 mm to 881 mm 23 7 16 590 mm 23 5 8 600 mm In...

Page 11: ...t Dimensions in each unit s Installation Guide Each door can be opened individually one at a time without interference However to ensure unobstructed door swing opening both doors at the same time 1 4...

Page 12: ...drill bit drill 3 pilot holes 5 8 16 mm deep into bottom of counter top Use the anti tip bracket as a template 4 Install 3 8x5 8 screws into the plate using a 2 Phillips head screwdriver SIDE MOUNT Si...

Page 13: ...l unit rear height of 1 8 3 mm less than the opening s rear height Shorten the unit height in the front by adjusting the front legs This allows the unit to be gently tipped into the opening Adjust the...

Page 14: ...bs 10 kg It is important to ensure that all drilled holes are drilled to the correct depth in order to avoid splits in the wood when hardware is installed 1 Cut the panels to the dimensions listed in...

Page 15: ...fectly with the door The appliance will need up to 34 1 2 876 mm to the underside of the counter to leave room for leveling adjustments A single prepared overlay with insert must not weigh more than 2...

Page 16: ...NTENANCE SERVICE Handleless Integrated Panel Dimensions 3 4 20 mm 28 13 16 732 mm 2 3 4 70 mm 2 3 4 70 mm R 5 8 R16 mm 1 8 3 mm 1 4 6 mm Wooden Insert Notch Depth 1 8 3 mm 2 3 8 60 mm 7 8 22 mm Ref To...

Page 17: ...dimensions listed in the appropriate diagram on the next page 2 Optional Stain or finish panel to desired stain or color Be sure to closely follow the instructions provided by the manufacturer 3 Optio...

Page 18: ...ed Panel Integrated Panel Integrated Frame Front Side Front Side 3 5 16 89 mm to 4 5 16 114 mm Floor Cabinet 3 5 16 89 mm 3 5 16 89 mm to 1 25 mm U Line Unit Extended Integrated Panel Extended Integra...

Page 19: ...Extended Integrated Panel Dimensions BACK SURFACE MUST HAVE AMPLE FLAT SURFACE TO MOUNT OVERLAY PANEL FLAT AND WITHOUT INTERFERENCE 23 1 2 595 mm 3 4 20 mm Integrated Panel 32 7 8 33 7 8 834 mm 860 mm...

Page 20: ...stain your grille plinth strip base fascia panel to match your surrounding furniture Finish front back and edges to prevent warping Carefully follow the manufacturer s recommendations for finish appli...

Page 21: ...e will not damage panel finish upon removal 7 Using a 7 64 3 mm drill bit drill 6 pilot holes into the wood panel 1 2 12 mm deep using the holes in the door frame as a guide NOTICE It is important to...

Page 22: ...strip base fascia rail with screw heads in base of unit 2 Push grille plinth strip base fascia rails towards the center of the unit and set rails over screw head 3 Slide grille plinth strip base fasc...

Page 23: ...installed adjacent to a wall 1 2 13 mm clearance is recommended from wall on hinge side to allow the door to open 90 Allow for additional space for any knobs or pulls installed on the integrated panel...

Page 24: ...pproximately 90 2 Remove hinge cover by lifting top and bottom of hinge cover and sliding the cover inwards to remove from hinge 3 Once cover is removed slide hinge pin into hole as shown Pin should s...

Page 25: ...that it is firmly in contact with the cabinet Also make sure the door gasket is not pinched on the hinge side of the door CAUTION Do not attempt to use the door to raise or pivot your unit This would...

Page 26: ...ve caps from screw heads on opposite side 2 on top and 2 on bottom Using 2 Phillips bit remove the 4 underlying screws Reinstall the screws and caps on the opposite side 5 Partially install screw 1 in...

Page 27: ...mmends allowing the unit to run overnight before loading with product When plugged in the unit will begin operating under the factory default setting Follow the on screen prompt for language selection...

Page 28: ...Press to select mode Press to set temperature Press to confirm temperature or wait 5 seconds Adjust lighting Press to adjust lighting Press to set low medium or high Light ON OFF with door Press to ha...

Page 29: ...perature It is important to only initiate quick chill modes when the Refrigerator or Wine Captain have been fully loaded with warm product Failure to follow this notice could result in food or beverag...

Page 30: ...ID Description Solution No Comm Unit lost communication to the display Disconnect and reconnect power to unit Contact Customer Care if persistent L R Zone T Open Left or right zone thermistor circuit...

Page 31: ...actual temperature select Actual Temps from the Customer Menu 2 Press or to scroll through available information 3 To return to the Customer Menu press Energy Saver Mode Energy Saver Mode reduces ove...

Page 32: ...nd Off To select a new sound level enter the Sound Level Menu from the Customer Menu 1 Press to select the current sound level 2 Press The current setting will begin to flash 3 Press or to select a di...

Page 33: ...ing while settings are restored When restoration is complete Restoring will return to Restore To exit Factory Default press to select Return to Menu and press to confirm Help To access the Help Menu s...

Page 34: ...still maintain internal temperatures and set points To enable Sabbath Mode 1 Open the unit s door to activate the display 2 To access the Customer Menu hold for 5 seconds 3 Press or to scroll through...

Page 35: ...een the internal fans or vents and product loaded Anything blocking the required airflow circulation will result in uneven temperature distribution in the cabinet and can also freeze product Do not in...

Page 36: ...subject of wine is your own palate Do not be afraid to make mistakes Experiment discover but most of all enjoy yourself and your new U Line product Guide To Common Styles Of Wine Matching Food and Wi...

Page 37: ...e presentation of the cork has a rich and fascinating history dating back to the late 1800 s A phylloxera root louse devastation to the vineyards severely limited the supply of great wines Restaurateu...

Page 38: ...at sediment is left undistributed and particles are not suspended vibration in a storage environment is not an issue Wines can become flat or tired when voids and vacuums are created inside the wine b...

Page 39: ...Each U Line Wine Captain model is designed to impress and inspire anyone with an interest in wine by providing cellar conditions in stylish undercounter units U Line Wine Captain models offer stable s...

Page 40: ...the bottles so the wine remains in contact with the cork which ensures the cork does not become dry U Line recommends arranging wine bottles as shown in the illustrations below Rack 1 Rack 2 Larger d...

Page 41: ...f Height Shelf height may be adjusted to accommodate a broad range of product To alter your shelf spacing follow the instructions below 1 Remove the 4 Shelf clips from the shelf clip holes 2 Move shel...

Page 42: ...otchbrite will cause the graining in the stainless steel to become blurred Rust not cleaned up promptly can penetrate the surface of the stainless steel and complete removal of the rust may not be pos...

Page 43: ...drain pan and possibly damaging water sensitive flooring the unit must be removed from cabinetry To defrost 1 Disconnect power to the unit 2 Remove all products from the interior 3 Prop the door in a...

Page 44: ...n necessary Depending on environmental conditions more or less frequent cleaning may be necessary WARNING Disconnect electric current to the unit before cleaning the condenser NOTICE DO NOT use any ty...

Page 45: ...cabinet NOTICE Do not remove the track rails from the cabinet To insert wine racks in the cabinet 1 Align the left and right rack channels with the tracks in the cabinet Ensure an even track engageme...

Page 46: ...is returned to service 3 If ice is on the evaporator allow ice to thaw naturally 4 Clean and dry the interior of the unit Ensure all water has been removed from the unit 5 The door must remain open t...

Page 47: ...re common refrigeration components with a brief description of the normal operating sounds they make NOTE Your product may not contain all the components listed Compressor The compressor makes a hum o...

Page 48: ...ature to a cooler set point Ensure unit is not located in excessive ambient temperatures or in direct sunlight Ensure the door is closing and sealing properly Ensure nothing is blocking the front gril...

Page 49: ...small increment see CONTROL OPERATION Causes which affect the internal temperatures of the cabinet include Temperature setting Ambient temperature where installed Installation in direct sunlight or ne...

Page 50: ...UG 220 240 VOLT PLUG OVERLOAD NEUTRAL WHITE 115v DARK BLUE 220 240v TO COMPRESSOR NEUTRAL WHITE 115v DARK BLUE 220 240v BLUE 115V LIGHT BLUE 220V 240V TO COMPRESSOR 1 10 CONTROL BOARD ZONE TEMP FUSE 1...

Page 51: ...nt of a part the servicer is authorized to replace the part in question The part that caused the damage must be returned to U Line in its entirety The part must be clearly labeled with the serial numb...

Page 52: ...shes 12 represents the production month In most cases warranty status can be verified by the production date information within the serial number Alternatively a Proof of Purchase or equivalent may su...

Page 53: ...00 13 Evaporator 80 54057 00 14 Evaporator cover 80 54042 00 15 Glass shelf 1 w brackets 80 54041 00 16 Grille w screws 80 54052 00 17 Hinge covers 2 pcs 80 54001 00 18 Hinge mounting hole covers 80 5...

Page 54: ...s will be shipped at no charge after U Line confirms warranty status Please provide the model serial number part number and part description Some parts will require color or voltage information If U L...

Page 55: ...federal state and local laws regarding refrigerants Gloves and Eye Protection must be used R 600a is considered non toxic but is flammable when mixed with air Keep a dry powder type fire extinguisher...

Page 56: ...equipment should be at least 10 feet from the work area It is recommended that a simple LPG gas detector is on site during service Ensure that all R 600a is removed from the system prior to brazing a...

Page 57: ...he system prior to repair simple venting is not sufficient Evacuate and charge with dry nitrogen for leak checks Repair leaks or replace system parts as required When re brazing the system must be pur...

Page 58: ...e access port on the compressor process stub Evacuate the system to 100 microns prior to charging Weigh in the R 600a charge using a refrigerant scale run compressor an extra two minutes to clear the...

Page 59: ...Lower than normal Warm near room temperature Hot Warm Warm Extremely cold near inlet Outlet below room temperature Lower than normal Partial Restriction Somewhat lower than normal vacuum Warm near ro...

Page 60: ...rounded to an electrical ground or grounded water pipe Handle circuit boards carefully and avoid touching components To measure the start winding resistance measure across the C and S pins To measure...

Page 61: ...of temperature and thermistor performance can be identified by directly viewing actual temperature readings in the service mode Component failure issues can be identified through service mode menu se...

Page 62: ...Section Control set too cold Refer to Adjusting Temperature Settings Section Review logged error codes Refer to Fault System Diagnosis Guide Thermistor failure Refer to Thermistor Failure Section Fros...

Page 63: ...could force the compressor into overload The compressor will automatically deactivate during an overload and will remain deactivated until the overload switch cools This could take some time It is im...

Page 64: ...is responsible for circulating warm air from the refrigeration zone past the evaporator and back into the refrigerated zone The evaporator fan is factory set to have a 1 minute delay at the beginning...

Page 65: ...points or damage Replace if necessary Inspect wire harness from main control board for pinch points or damage Repair split or pinched cabling Amb Thrm Short Inspect thermistor cable for pinch points o...

Page 66: ...evaporator thermistor fails the unit will rely on a preset defrost time during defrost cycles The unit will otherwise operate normally Evaporator thermistor errors will be displayed in the error log A...

Page 67: ...FRQGHQVHU IDQV DQG OLJKWLQJ R Oow med high OFFSETS ARE USED TO ADJUST OR CORRECT THERMISTOR READINGS CORRECTED VALUES MAY BE VIEWED THROUGH THE CUSTOMER MENU SELF TEST IS USED TO DIAGNOSE THE BOARD IF...

Page 68: ...user interface Check the black to red conductors looking for 5 VDC If voltage is present replace the user interface If no voltage is present check for 5 VDC at the main board where the communication...

Page 69: ...r Temp Hi 6H Zone temperature 10 F over set point for over 6 hours Is condenser coil clean Is condenser fan operating Check zone thermistor for correct resistance Verify thermistor connections are cle...

Page 70: ...nput To access Input Status 1 Press to select Input Status 2 Press 3 Press and to scroll through available information To exit the Input Status menu press to select Return to Menu and press to confirm...

Page 71: ...select Offsets 2 Press 3 Press and to scroll through available thermistors To change offsets 4 Press the selected thermistor will begin to flash 5 Press or to modify offset value 6 Press to confirm s...

Page 72: ...Fan runtime in minutes from 0 to 98 and OFF cycle time 0 to 98 To access Evap Fan 1 Press to select Evap Fan 2 Press 3 Press and to scroll through available settings To exit the Evap Fan menu press to...

Page 73: ...ws the units model information to be modified Changing the units model completely reprograms available zones relay assignments DC output assignments etc To access Re Select Model 1 Press to select Re...

Page 74: ...is delayed from starting with the cooling cycle for a given amount of time In order to remove as much warmth as possible from the cabinet the evaporator fan will continue to run at the end of the cool...

Page 75: ...o flash 4 Press or to toggle between off and on 5 Press to confirm If set to on showroom mode will begin immediately To exit showroom mode press and hold for 5 seconds and release The display will sho...

Page 76: ...e Control Operations Service section This unit has three thermistors Thermistor one Zone Located along the right hand side wall It is used to maintain the operating temperature within that zone Thermi...

Page 77: ...ta Temp F Temp C Nominal Resistance OHMS 40 40 169157 31 35 121795 22 30 88766 13 25 65333 4 20 48614 5 15 36503 14 10 27681 23 5 21166 32 0 16330 41 5 12696 50 10 9951 59 15 7855 68 20 6246 77 25 500...

Page 78: ...C 1224 RF 12 45 15 9 1215 1224 2218 2245 2224 2260 WC ZWC 12 45 45 7 1215 1224 2218 2245 2224 2260 R RSOD RDC BEV DC DWR RGL 12 45 42 6 CO29 F 12 18 n a CO1224 F 12 18 45 7 1224FZR Freezer Mode 6 45...

Page 79: ...ondensation that may have appeared on glass doors and shelves Note If the unit is set to sabbath mode the evaporator fan will no longer respond to the state of the door switch In order to operate effi...

Page 80: ...ator cover vents and push air out at fan mounting location 15 Installation is the reverse of removal 16 Care must be taken to assure the bottom of the evaporator cover is reinstalled behind the front...

Page 81: ...nty arising by operation of law U Line will not be responsible for any consequential or incidental damages arising from the breach of these warranties or any other warranty whether express implied or...