U-Line 3018R User Manual & Service Manual Download Page 1

 

 

USER GUIDE & SERVICE MANUAL

 

SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE

 

Modular 3000 Series  

 

3018R  

 

18" Solid Door Refrigerator

 

SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE 

 

 

Contents

 

          Intro

 

Safety

 

          Safety and Warning

 

RIGHT PRODUCT. RIGHT PLACE. RIGHT TEMPERATURE. SINCE 1962.

 

Summary of Contents for 3018R

Page 1: ...ATING INSTRUCTIONS MAINTENANCE SERVICE Modular 3000 Series 3018R 18 Solid Door Refrigerator SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE Contents Intro Safety Safety and...

Page 2: ...ctions First Use Control Operation Sabbath Mode Airflow and Product Loading Refrigerator Bins Crisper Maintenance Cleaning Cleaning Condenser Extended Non Use WELCOME TO U LINE Congratulations on your...

Page 3: ...DAMAGE INJURY CONCERNS In the unlikely event property damage or personal injury is suspected related to a U Line product please take the following steps 1 U Line Customer Care must be contacted immedi...

Page 4: ...this safety statement could result in serious personal injury or death CAUTION Caution means that failure to follow this safety statement may result in minor or moderate personal injury property or e...

Page 5: ...ren may not easily climb inside If the unit is being removed from service for disposal check and obey all federal state and local regulations regarding the disposal and recycling of refrigeration appl...

Page 6: ...ambient temperatures may reduce the unit s ability to reach low temperatures and or reduce ice production on applicable models For best performance keep the unit out of direct sunlight and away from h...

Page 7: ...extension cord to connect power to the unit Always keep your working area dry NOTICE Electrical installation must observe all state and local codes This unit requires connection to a grounded three p...

Page 8: ...urements The opening must be square and plumb front to back Although not required you may choose to increase the overall cutout width for ease of installation The Modular 3000 Series units are enginee...

Page 9: ...SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE USER GUIDE u line com Product Dimensions...

Page 10: ...sted under Cutout Dimensions in each unit s Installation Guide Each door can be opened individually one at a time without interference However to ensure unobstructed door swing opening both doors at t...

Page 11: ...try 3 Using a 3 32 2 50 mm drill bit drill 3 pilot holes 5 8 16 mm deep into bottom of counter top Use the anti tip bracket as a template 4 Install 3 8x5 8 screws into the plate using a 2 Phillips hea...

Page 12: ...ning adjust the rear legs to achieve a total unit rear height of 1 8 3 mm less than the opening s rear height Shorten the unit height in the front by adjusting the front legs This allows the unit to b...

Page 13: ...Finish or stain your grille plinth strip base fascia panel to match your surrounding furniture Finish front back and edges to prevent warping Carefully follow the manufacturer s recommendations for f...

Page 14: ...ille plinth strip base fascia rail with screw heads in base of unit 2 Push grille plinth strip base fascia rails towards the center of the unit and set rails over screw head 3 Slide grille plinth stri...

Page 15: ...door approximately 90 2 Remove hinge cover by lifting top and bottom of hinge cover and sliding the cover inwards to remove from hinge 3 Once cover is removed slide hinge pin into hole as shown Pin s...

Page 16: ...xamine the door s gasket to ensure that it is firmly in contact with the cabinet Also make sure the door gasket is not pinched on the hinge side of the door CAUTION Do not attempt to use the door to r...

Page 17: ...N INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE USER GUIDE u line com b y l i f t i n g t o p a n d b o t t o m f l a p s a n d s l i d e i n w a r d s R e p e a t o n b o t t o m h i n g e D...

Page 18: ...s from screw heads on opposite side 2 on top and 2 on bottom Using 2 Phillips bit remove the 4 underlying screws Reinstall the screws and caps on the opposite side 5 Partially install screw 1 in the o...

Page 19: ...SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE USER GUIDE u line com Door Adjustments 2...

Page 20: ...ds allowing the unit to run overnight before loading with product When plugged in the unit will begin operating under the factory default setting Follow the on screen prompt for language selection and...

Page 21: ...ium or high Light ON OFF with door Press to have light on off with door Press and release to scroll through timer settings Customer menu Press and hold for 5 seconds Press to scroll through menu Mode...

Page 22: ...tables Potatoes Onions Lemon Lime Melon Peppers Beans Cucumber Cut Vegetables QUICK CHILL CAUTION Quick chill is designed to quickly pull warm beverages and foods down to optimum storage temperature I...

Page 23: ...Thrm Short Ambient thermistor circuit shorted Contact Customer Care L R Temp Hi 6H Left or right zone temperature 10 over set point for over 6 hours Verify door is closed and sealing Contact Customer...

Page 24: ...ergy Saver Mode a small leaf icon will be displayed on the main screen 1 To enter Energy Saver Mode first select Energy Saver from the Customer Menu 2 Press to select Off in the menu 3 Press 4 Press t...

Page 25: ...layed in either Fahrenheit or Celsius To change from Fahrenheit to Celsius enter the Fahrenheit Celsius Menu from within the Customer Menu 1 Press to select Degrees 2 Press The selection will begin to...

Page 26: ...nd press to confirm Help To access the Help Menu select Help from the Customer Menu Press to scroll through available information The Help screen displays the following Model U Line contact informatio...

Page 27: ...n internal temperatures and set points To enable Sabbath Mode 1 Open the unit s door to activate the display 2 To access the Customer Menu hold for 5 seconds 3 Press or to scroll through available sel...

Page 28: ...ts at any time or the unit will not perform as expected When loading your unit leave space between the internal fans or vents and product loaded Anything blocking the required airflow circulation will...

Page 29: ...e bin off the racks 3 Lift the rear of the bin off its seat on the rack 4 Pull the bin up and away from the racks To Reinstall 5 Fully extend the empty rack from within the cabinet 6 Set the rear of t...

Page 30: ...brite will cause the graining in the stainless steel to become blurred Rust not cleaned up promptly can penetrate the surface of the stainless steel and complete removal of the rust may not be possibl...

Page 31: ...he drain pan and possibly damaging water sensitive flooring the unit must be removed from cabinetry To defrost 1 Disconnect power to the unit 2 Remove all products from the interior 3 Prop the door in...

Page 32: ...an the condenser when necessary Depending on environmental conditions more or less frequent cleaning may be necessary WARNING Disconnect electric current to the unit before cleaning the condenser NOTI...

Page 33: ...nit is returned to service 3 If ice is on the evaporator allow ice to thaw naturally 4 Clean and dry the interior of the unit Ensure all water has been removed from the unit 5 The door must remain ope...

Page 34: ...USER GUIDE u line com Extended Non Use 1...

Page 35: ...e a tendency to reflect normal appliance operating noises Listed below are common refrigeration components with a brief description of the normal operating sounds they make NOTE Your product may not c...

Page 36: ...displayed on the user interface See below for a list of errors NOTE Single zone models will not use L left or R right zone indicators in error notification ID Description Solution No Comm Unit lost c...

Page 37: ...ater If required adjust the temperature control in a small increment see CONTROL OPERATION Causes which affect the internal temperatures of the cabinet include Temperature setting Ambient temperature...

Page 38: ...that U Line will provide either under these warranties or under any warranty arising by operation of law U Line will not be responsible for any consequential or incidental damages arising from the br...

Page 39: ...STALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE USER GUIDE u line com Copyright 2014 2017 U Line Corporation All Rights Reserved Publication Number 30379 04 2017 Rev K Warranty 1 Wir...

Page 40: ...nt of a part the servicer is authorized to replace the part in question The part that caused the damage must be returned to U Line in its entirety The part must be clearly labeled with the serial numb...

Page 41: ...n year The number between the dashes 12 represents the production month In most cases warranty status can be verified by the production date information within the serial number Alternatively a Proof...

Page 42: ...SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE USER GUIDE u line com Warranty Claims 1...

Page 43: ......

Page 44: ...at no charge after U Line confirms warranty status Please provide the model serial number part number and part description Some parts will require color or voltage information If U Line requires the r...

Page 45: ...king up Lower than normal Complete Restriction In deep vacuum Room temperature cool Room temperature cool Room temperature cool Room temperature cool No refrigeration Lower than normal No Gas 0 PSIG t...

Page 46: ...e not shorted check the S and R to ground EMX20CLC Refrigerant R600a Voltage 115 127 VAC Frequency 60 Hz Run Cap 12 F 165 VAC Start Winding 6 7 Ohm at 77 F Run Winding 12 6 Ohm at 77 F LRA 3 7 A FLA 0...

Page 47: ...on explanations Verification of temperature and thermistor performance can be identified by directly viewing actual temperature readings in the service mode Component failure issues can be identified...

Page 48: ...uct Ensure proper use of Quick Chill mode Refer to Control Operation Section Control set too cold Refer to Adjusting Temperature Settings Section Review logged error codes Refer to Fault System Diagno...

Page 49: ...e board for any suspected failures before attempting to remove the board for replacement or service Follow the guidelines below to fully test and diagnose the main control Power Fault If the unit does...

Page 50: ...ing the unit to its factory default setting Factory defaults may be restored through the service menu CAUTION Precautions must be taken while working with live electrical equipment Be sure to follow p...

Page 51: ...ect wire harness from main control board for pinch points or damage Repair split or pinched cabling Temp Hi 6H If excessive frost is also noted inspect door and door gasket for proper seal and alignme...

Page 52: ...les The unit will otherwise operate normally Evaporator thermistor errors will be displayed in the error log Always assure that all thermistor connections are clean and dry Whenever opening a thermist...

Page 53: ...E USED TO DETERMINE AT WHAT TEMPERATURE THE UNIT CYCLES O SETTING IS 2 DIFFERENTIAL RETURN TO MENU DIFFERENTIALS LEFT 16 C RIGHT 16 C EVAP FAN THIS MENU IS USED TO SET THE DURATION THE EVAPORATOR FAN...

Page 54: ...t the main board where the communication cable plugs onto the pins for the red and black conductors If 5 VDC is not present replace the main control board If 5 VDC is present replace the communication...

Page 55: ...n of zone valve Temp Lo Zone temperature Verify thermistor connections 12H 10 F under set are clean and dry Verify point for over 12 thermistor resistance Verify hours correct operation of zone valve...

Page 56: ...porator Fan DC F3 Condenser Fan DC L1 Zone Lighting DC To access Relay Toggle 4 Press to select Relay Toggle 5 Press 6 Press to scroll through each relay and DC output 7 Press to toggle To exit the Re...

Page 57: ...tomer All Temps menu To access Offsets 1 Press to select Offsets 2 Press 3 Press and to scroll through available thermistors To change offsets 4 Press the selected thermistor will begin to flash 5 Pre...

Page 58: ...ith various differentials Evap Fan The Evap Fan option in the service menu allows servicers to change the Evaporator Fan runtime in minutes from 0 to 98 and OFF cycle time 0 to 98 To access Evap Fan 1...

Page 59: ...he manufacturer warranty Re Select Model allows the units model information to be modified Changing the units model completely reprograms available zones relay assignments DC output assignments etc To...

Page 60: ...f fan run times during and after a cooling cycle In order to allow time for the evaporator to properly cool the evaporator fan is delayed from starting with the cooling cycle for a given amount of tim...

Page 61: ...select Off and press Off will begin to flash 4 Press to toggle between off and on 5 Press to confirm If set to on showroom mode will begin immediately To exit showroom mode press and hold for 5 secon...

Page 62: ...tion can be found in the Control Operations Service section This unit has three thermistors Thermistor one Zone Located along the right hand side wall It is used to maintain the operating temperature...

Page 63: ...or 1 Thermistor Resistance Data Temp F Temp C Nominal Resistance OHMS 40 40 169157 31 35 121795 22 30 88766 13 25 65333 4 20 48614 5 15 36503 14 10 27681 23 5 21166 32 0 16330 41 5 12696 50 10 9951 59...

Page 64: ...ost Hours Duration in Minutes Minimum Duration in Minutes Maximum Stop Temperature F C Beverage Drinks 12 5 60 42 6 Market Fresh 12 5 60 42 6 Root Root Cellar 12 5 60 45 7 Pantry 12 5 60 42 6 White Wi...

Page 65: ...d free of any dust buildup Evaporator Fan Replacement Should the evaporator fan need to be replaced follow the steps below 1 Remove any product from the unit 2 Uninstall unit 3 Disconnect power to the...

Page 66: ...ough lower evaporator cover vents and push air out at fan mounting location 15 Installation is the reverse of removal 16 Care must be taken to assure the bottom of the evaporator cover is reinstalled...