background image

Operating Instructions

DME24MW



 / DME24UW



Index 003

Original operating Instructions

10995607 en / 03.03.2016

DME24MW



DME24UW



Summary of Contents for / DME24UW Series

Page 1: ...Operating Instructions DME24MW DME24UW Index 003 Original operating Instructions 10995607 en 03 03 2016 DME24MW DME24UW...

Page 2: ...YROLIT Hydrostress re placement parts can guarantee quality and interchangeability If maintenance work is neglect ed or carried out inexpertly we will be unable to honour our warranty obligations Any...

Page 3: ...4MW DME24UW Table of contents Page 1 Concerning these instructions 4 2 Safety 5 3 Product description 8 4 Design and Function 11 5 Assembly Disassembly 13 6 Operation 15 7 Servicing and Maintenance 17...

Page 4: ...gineers at all times Pass the instructions on to all subsequent owners or users of the equipment Update instructions with all supplements received from the manufacturer Symbols in these instructions D...

Page 5: ...ents are operating correctly Signs on the equipment Safety sign 1 Wear safety shoes 3 Wear a breathing mask 5 Read the instructions 2 Wear gloves 4 Wear a helmet goggles and hearing protection 6 Befor...

Page 6: ...e can be found in the Core Drills Safety Manual System Manual Product specific dangers Personal protection device PRDC GFCI Only ever work if a serviceable current operated personal protection device...

Page 7: ...erosols Inhaling damaging vapours and or aerosols can cause breathing problems Breathing in the water fog that is created is a health hazard X X Wear a breathing mask X X Provide adequate ventilation...

Page 8: ...stand controlled wet drilling into mineral subsurfaces using diamond drill bits no manual operation During operation a suitable drilling stand must be used and sufficient anchoring to the subsurface...

Page 9: ...ol fitting external 1 UNC Tool fitting internal G Operation drill rig controlled Application wet Electronic overload protection Yes Mechanical overload protection Yes PRCD protective switch Yes Power...

Page 10: ...ts Measurements in mm Lubricants fluids Lubricants fluids and sealants Parameter Value Gear oil ISO 100 TYROLIT No 10993830 250ml Name plate The type designation and serial number are marked on the na...

Page 11: ...otor Function Functional description The drilling spindle of the electrical tool is powered by an electric motor via a mechanical manual gearbox The optimum speed of the cutting tool is set using the...

Page 12: ...lay when at standstill LED 1 illuminates in green Electrical tool is ready LED 3 flashes in orange Electrical tool requires service Power display during operation LED 1 2 illuminates in green Motor op...

Page 13: ...TYROLIT Hydrostress AG Page 13 DME24MW DME24UW Assembly Disassembly Drill rig interface Drill rig interface Cutting tool interface Cutting tool interface 5 5 1 5 2...

Page 14: ...lectrical tool pull out the plug Extension cable Only use approved and appropriately marked extension cables outdoors Extension cables with multiple sockets and simultaneous use of multiple devices mu...

Page 15: ...body is earthed Settings Gears Position the selector switch in accordance with the required drilling diameter Never use force to move the switch and only move it if the electrical device is slowing d...

Page 16: ...X X Contact TYROLIT Hydrostress AG aftersales Faulty power supply X X Check power supply Electric motor or electronics faulty X X Contact TYROLIT Hydrostress AG aftersales Electrical tool starts up an...

Page 17: ...sales adviser 7 Servicing and maintenance table Before each use At end of work Weekly Yearly After faults After damage Drive motor X X Tighten loose screws and nuts X X Check cleanliness X X X Drill b...

Page 18: ...oduct complies with the following direc tives and standards Applied directions 2006 42 EC 17 05 2006 2014 30 EU 26 02 2014 2012 19 EU 04 07 2012 Applied standards EN ISO 12100 2010 EN 61029 1 2009 EN...

Page 19: ...TYROLIT Hydrostress AG Page 19 DME24MW DME24UW...

Reviews: