Tynetec ZXT830 Quick Start Manual Download Page 1

Tynetec, a business unit of Legrand Electric Ltd 

Cowley Road, Blyth Riverside Business Park, Blyth, Northumberland, NE24 5TF. 

Tel: +44 (0) 1670 352371    www.tynetec.co.uk 

Trusted Technology 

Caring for People 

Door Alarm 
869MHz

 

Caring for People 

 
 

 

 
_________________________________________________________________________

 

________________________________________________________________ 

 
 

 
 

 

 

  Doc No. FM0826 V1.04 Page 1   

 

 

 

 

 

 

 

 

 

 

 

 

Fixed trigger device 

 

Used to support the care of dementia patients 

 

Compatible with Reach IP and Advent XT2 

 

Complies with BS EN 50134-2:2017 

 

Integrated left and right-side reed switches 

 

Surface magnetic door contact 

 

Red alarm transmit LED indicator  

 

Green alarm received LED indicator 

 

2 No. AAA Alkaline batteries 

 

Low battery warning 

 

Operating Temperature: +5

o

C to +40

o

C  

 

Telecare Transceiver: 869.2125MHz Class 1.5 

 

Digital Heartbeat 

 

Weight: 55 grams 

 

Dimensions: 85mm x 34mm x 24mm (HxWxD) 

 

Product Code: ZXT830

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 

Positioning

 

The door alarm can be mounted on the door frame and 
the magnet on the door, or vice-versa. The magnet can be 
placed on either side of the door alarm. The distance 
between the door alarm and the magnet must not exceed 
10mm when the door is closed. If the door is made from 
metal the magnet may need to be closer.  

 

Alarm Condition

 

When a monitored door is opened, it transmits an alarm 
and the LED will illuminate red for 4 seconds. When the 
alarm is acknowledged by the Telecare system the LED will 
illuminate green for 2 seconds. A new alarm will not be 
triggered until the door has been closed and opened again. 
 

Low Battery Condition

 

A low battery condition will be reported automatically to 
the Alarm Receiving Centre (ARC) or the local Manager. 
The batteries should be replaced as soon as possible within 
30 days.  
 

Out of Range Notification (Reach IP)

 

The Reach IP can monitor all radio peripheral devices to 
determine whether they have been damaged or removed 
from an installation. Should the Reach IP be unable to 

detect a device’s heartbeat it will automatically generate a 
“radio out of range” notifi

cation. Firstly, investigate if 

there’s a genuine reason for the alert, if not, arrange for 

the peripheral device to be replaced immediately.  

The “Radio out of range timer” can be set from 30 hours to 
99999 hours in Pulse CMP. “Radio supervision” can be 

disabled by unchecking the tick box associated with each 
peripheral device in Pulse CMP.

 

 

Maintenance

 

Test the door alarm once every month. 
Clean with a damp cloth, do not use solvents or cleaners 
on the door alarm. 
 

Disposal

 

Waste electrical products should not be disposed of with 
normal household waste. The door alarm is ideally suited 
for disposal within the waste electronic and electrical 
equipment (WEEE) recycling scheme.  
Please recycle where facilities exist.  
Check with your local authority or contact your supplier for 
recycling/disposal advice. 

 

 