4
Sauna
Sauna
sub-menus:
•
Bath type priority
: Select how heating up is to be prioritised.
The basic priority is automatic (under 70°C steam production
is prioritised. Heating up the cabin is prioritised over 70°C).
The sauna priority means that steam production will not start
before the cabin has reached the set temperature. Steam pri-
ority means that steam production is prioritised, but 2 of the
heater elements will activate to heat up the cabin.
•
Standby
: You can define by how much the temperature will
be reduced when the heater is programmed for
Standby
.
General
General
sub-menus:
•
Set time
: Set the timer
•
Set date
: Set date here
•
Region
: Set language, temperature format (°C/°F) and time
format (12 or 24 hour).
•
Sleep delay
: The time from when the control panel becomes
inactive until the display shuts down. This can also be used to
shut off the Sleep delay.
•
Keylock
: Keylock - You can choose automatic keylock (the
panel locks after a given time. Can be unlocked by press-
ing
HOME
and
BACK
simultaneously (see
Figure 10,
Page
4), to lock the panel using a code (to use the panel the
correct code has to be entered) and change the lock code.
You can also define the time interval that should elapse before
the code lock is activated. For more details, see The section
called
Locking the panel
, Page 4.
•
Vibration
: You can select whether the panel will vibrate
slightly when pressing the buttons or not.
•
About
: Shows details of the system. Which software and
hardware versions and product in use.
Figure 10:
HOME and BACK
Service
To access the service menu, enter code 124.
Service
sub-menus:
•
Settings
sub-menus:
–
Bathtime limit
: The maximum time allowed for using the
sauna.
–
External switch bathtime
: Defines the sauna time when an
external switch is used
–
External switch function
: Select between
On/Off
and
Re-
start sauna time
. See section on external switch.
–
Temperature limit
: Maximum sauna temperature
–
Overheating limit
: When the temperature on the circuit
board exceeds a set temperature, the heater will shut down to
prevent damage to the electronics or other components. The
function can be cancelled and the temperature limit changed.
Changing the temperature is not recommended without find-
ing out what caused the temperature increase in the electron-
ics.
–
Filtered temperature
: Defines whether you want to see an
exact value at the thermistor. To avoid large temperature fluc-
tuations on the display, the filtered value should be shown.
–
Reset pause timer
: When a timer-controlled system is se-
lected, the mandatory pause of 6 or 12 hours can be reset
here.
•
Diagnosis
sub-menus:
–
Relay control
: For Tylös service technicians only
–
Extra relay control
: For Tylös service technicians only
–
System status
: Shows the current status of water level,
sauna temperature, sauna hours, system type and product.
–
Heater grid node list
: Shows which products are connec-
ted to the system.
–
Error log
: Any errors on the system are logged here.
•
Factory reset
Code 421 is required to reset to factory set-
tings. The control panel will reset to factory settings.
Locking the panel
The panel can be locked to prevent unauthorised setting. To lock
the panel, press
HOME
and
BACK
simultaneously for 2 seconds
(see
Figure 11,
Page 4).
Figure 11:
HOME and BACK
When the panel is locked,
LOCKED STATUS
(see
Figure 12,
Page 4) is shown in the status bar.
Figure 12:
LOCKED STATUS
To unlock the panel, press
HOME
and
BACK
simultaneously for
about 2 seconds.
NOTE!
When the control panel is locked, the light but-
ton will still work.
Summary of Contents for H2
Page 1: ...1205 ENGLISH USER AND INSTALLATION GUIDE H2 OK 29005140 ENG ...
Page 12: ......
Page 13: ...1205 SVENSKA BRUKS OCH MONTERINGSANVISNING H2 OK 29005140 SVE ...
Page 24: ......
Page 25: ...1205 РУССКИЙ ИНСТРУКЦИЯ ПО МОНТАЖУ И ЭКСПЛУАТАЦИИ H2 OK 29005140 RYS ...
Page 36: ......
Page 37: ...1205 DEUTSCH GEBRAUCHS UND MONTAGEANLEITUNG H2 OK 29005140 TYS ...
Page 48: ......
Page 49: ...1205 FRANÇAIS NOTICE DE MONTAGE ET D UTILISATION H2 OK 29005140 FRA ...
Page 60: ......