background image

TYLÖ AIR

1604

2900 5230

SVENSKA

INSTALLATIONSANVISNING

ENGLISH

INSTALLATION GUIDE

DEUTSCH

INSTALLATIONSANLEITUNG

FRANÇAIS

NOTICE D’INSTALLATION

РУССКИЙ

ИНСТРУКЦИИ

 

ПО

 

УСТАНОВКЕ

POLSKI

INSTRUKCJA INSTALACJI

NEDERLANDS

INSTALLATIEHANDLEIDING

A

Summary of Contents for Air 10

Page 1: ...5230 SVENSKA INSTALLATIONSANVISNING ENGLISH INSTALLATION GUIDE DEUTSCH INSTALLATIONSANLEITUNG FRANÇAIS NOTICE D INSTALLATION РУССКИЙ ИНСТРУКЦИИ ПО УСТАНОВКЕ POLSKI INSTRUKCJA INSTALACJI NEDERLANDS INSTALLATIEHANDLEIDING A ...

Page 2: ...ly with the instructions in this manual Installation tools The following tools and materials are needed for installation and connection water level adjustable spanner screwdrivers Installation planning Before starting to install your sauna heater you should Plan the sauna heater positioning see the Heater positioning normal installation section page 8 Plan the control panel positioning see the att...

Page 3: ... concrete brick etc or of hardened glass the sensor may be installed in the ceiling at a distance from the heater according to Figure 4 1 4 8 11 10 2 6 5 9 7 3 3 Figure 3 Positioning the heater normal installation 1 Minimum distance from the side wall 120 mm 2 Sensor position alt 1 700 mm from the heater 3 Sensor 4 Minimum distance from the back wall 120 mm 5 Sensor position alt 2 700 mm from the ...

Page 4: ... Connect the electrical cable 1 to the terminal 2 see Figure 8 according to the wiring diagram see the Connection wiring diagram section page 11 INSTALLATION Sauna heater installation It is easiest to prepare for installation with the heater lying down To install the heater 1 Lay the heater down with the front facing upwards 2 Undo the screws and open the cover see Figure 7 DANGER The air exhaust ...

Page 5: ...wiring diagram section according to the wiring diagram see the Connection wiring diagram section page 11 6 Connect the light cable if relevant 7 see Figure 8 page 9 to the terminal 8 according to the wiring diagram Figure 11 page 11 7 Close the cover and tighten the screws see Figure 7 page 9 8 Install the sensor on the wall see Figure 9 The thermistor wire may also be passed through the wall Seal...

Page 6: ...ntrol panels 7 RS485 control panels 8 RS485 control panels 9 Heater 10 Terminal for connection of electrical cable 11 Control panel connect to positions 5 8 12 Sensor connect to NTC position 1 13 Lighting terminal for connection of lighting 14 Door contact option 15 External switch option 9 13 14 15 11 12 1 2 3 4 5 6 7 8 11 10 13 RJ10 4P4C 2 x 1 5 mm 2 3 x 1 5 mm 2 RJ10 4P4C RJ10 4P4C RJ10 4P4C B ...

Page 7: ...5 control panels 6 RS485 control panels 7 RS485 control panels 8 RS485 control panels 9 Modular plug 10 Modular contact Table 3 Connecting components in modular contacts maximum cable area for RJ10 0 90 mm 0 20 mm AWG24 Connection of Position Pin Comment Temperature sensor 10K ohm 1 2 3 Must be an NTC model May also be connected at Position 4 External switch with no wire indicator 2 3 4 Both const...

Reviews: