Use of this Manual

This manual covers the installation and operation of the Raychem

®

QuickStat

thermostat and must be used with the following document:

QuickNet

System Installation Manual

(H57704)

Important:

For the Tyco Thermal Controls warranty and agency

approvals to apply, the instructions included in this manual and product
packages must be followed.

Features

QuickStat is an electronic thermostat that must be used with the
Raychem QuickNet floor warming mats. 

QuickStat provides the following features:

• Includes an integrated Class A, Ground-fault Circuit Interrupter (GFCI).

• Operates at 120/240 V 50/60 Hz.

• Switches on your heating system at predetermined times on different

days of the week.

• Offers 4 periods (called events) each day that you can set at different

temperatures.

• Comes with a preprogrammed schedule that is suitable for most

installations. However, you can customize this program any time you
wish.

• Allows you to reset the thermostat to factory settings. 

• Changes the start time of a heating period automatically so that the

desired temperature is reached at the time that you set. 

• Controls the temperature of the floor through a temperature sensor

that is placed in the floor construction.

Specifications

Approvals

Technical Data

Supply Voltage

120/240 V ±15%, 50/60 Hz

Maximum switching current

16 A 

Wiring

12 AWG to 22 AWG

GFCI

Class A (5 mA trip level)

Temperature control range 

40 to 104˚F (5 to 40°C)

Ambient temperature range

Thermostat 

32 to 104˚F (0 to 40°C)

GFCI 

–31 to 149˚F (–35 to 65°C)

C

US

LISTED

 2D03

E157297

A

B

C

Kit contents

A

1

QuickStat thermostat

B

2

Mounting screws

C

1

Floor temperature sensor 10 ft (3m)

Summary of Contents for QuickStatTM

Page 1: ...ays of the week Offers 4 periods called events each day that you can set at different temperatures Comes with a preprogrammed schedule that is suitable for most installations However you can customize...

Page 2: ...cold lead to the load terminals marked Load 16A Max 3 Connect the floor warming cold lead braid ground to the supply ground in the electrical junction box 4 Connect the floor temperature sensor to the...

Page 3: ...ppear If this does not occur check the installation 1 Press the RESET button to reset the GFCI The red light should disappear and the display will return to normal appearance 2 Press the OK button to...

Page 4: ...ning thermostat off To turn the thermostat OFF press the DOWN button until you reach 41 F press the OK button then press the once more DO NOT USE THE TEST BUTTON ON THE GFCI TO SWITCH OFF THE HEATING...

Page 5: ...rature setting range of 41 F to 104 F can be limited to prevent a too high or too low temperature from being selected Set the maximum allowed temperature Use the UP or DOWN button to increase or reduc...

Page 6: ...ols makes no warranties as to the accuracy or completeness of the information and disclaims any liability regarding its use Tyco Thermal Controls only obligations are those in the Tyco Thermal Control...

Page 7: ...ents jours de la semaine 4 p riodes ou v nements par jour pour le r glage de temp ratures diff rentes Programme standard convenant pour la plupart des installations Ce programme peut tre personnalis v...

Page 8: ...6A Max 3 Brancher le faisceau de fils froids du syst me de chauffage de sol terrre mise la terre de l alimentation dans la bo te de jonction lectrique 4 Brancher la sonde de temp rature du plancher au...

Page 9: ...e du thermostat dispara t Si ce n est pas le cas v rifiez l installation 1 Appuyez sur le bouton RESET de r armement du disjoncteur Le voyant rouge doit s teindre et l affichage r appara tre 2 Appuyez...

Page 10: ...onctionnement automatique Arr t complet du chauffage Pour arr ter le chauffage appuyez sur le bouton MOINS jusqu ce que la temp rature atteigne 41 F puis appuyez sur le bouton OK et nouveau sur N UTIL...

Page 11: ...4 F peut tre limit e pour viter que quelqu un s lectionne une temp rature trop haute ou trop basse Pour r gler la temp rature maximum per mise appuyez sur les boutons PLUS ou MOINS pour augmenter ou r...

Page 12: ...o Thermal Controls makes no warranties as to the accuracy or completeness of the information and disclaims any liability regarding its use Tyco Thermal Controls only obligations are those in the Tyco...