TL280(R)

Internet Alarm Communicator - North America

I

NSTALLATION

 M

ANUAL

 

V

4.0

Warning: 

This manual contains information on limitations regarding product use

and function and information on the limitations as to liability of the manufacturer.

firealarmresources.com

Summary of Contents for DSC TL280

Page 1: ...cator North America INSTALLATION MANUAL V4 0 Warning This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufa...

Page 2: ...firealarmresources com...

Page 3: ...or Troubleshooting 14 Ethernet Programming Options 15 System Options 15 Communications Reporting Codes 24 Ethernet Receiver 1 Options 25 Ethernet Receiver 2 Options 26 Ethernet Options 27 Receiver Dia...

Page 4: ...their belongings Motion Detectors Motion detectors can only detect motion within the designated areas as shown in their respective installation instructions They cannot discriminate between intruders...

Page 5: ...ssories only with this equipment Do not stay close to the equipment during device operation Model Information This manual covers the following alarm communicator models TL280 and TL280R Models end ing...

Page 6: ...each channel is independent The communicator can also be used as an active communication system with the security levels A1 A4 each channel independent For active line security systems AES128 bit enc...

Page 7: ...cording to the local electrical codes The communicator shall be installed by service persons only service person is defined as a person having the appropriate technical training and experience necessa...

Page 8: ...ls only When installing the communicator for use with 3rd party applications an RS 422 cable must be connected between the 3rd party device and the communicator module NOTE Maximum cable length for RS...

Page 9: ...nel perform the following steps See Figure 3 a Disconnect both AC power and battery connections from the panel and disconnect tele phone line 4 Install the RS 422 connections R models only If using th...

Page 10: ...ted systems Keypad Data Display Section Toggle Options The number is displayed when toggle is ON the number is not dis played when toggle is OFF e g toggle options displays 3 6 Options 3 and 6 are ON...

Page 11: ...session through Ethernet NOTE Before leaving the premises the installer should verify all programmed communications paths See programming options section 851 901 to send immediate test transmissions N...

Page 12: ...ed on receipt of first poll from the panel Ethernet Trouble 6 Flashes This trouble is indicated when Ethernet link between the transmitter and the local switch or router is absent This trouble will al...

Page 13: ...hort the hardware default pins 4 and 5 4 Remove AC and DC power from the panel and then reapply power to the panel 5 Wait 30 seconds 6 Remove the jumper from the hardware default pins 4 and 5 green LE...

Page 14: ...confirm that the gateway and subnet mask are entered correctly If the network has a firewall ensure the network has the programmed outgoing ports open default UDP port 3060 and port 3065 Ensure that a...

Page 15: ...elds each field is 3 digits Valid range 000 255 NOTE If DHCP is enabled the DHCP server will assign the subnet mask for this section and the programmed value will be ignored 003 Ethernet Gateway IP Ad...

Page 16: ...red to meet the approval for the installation OFF Events will be communicated to the receivers individually Toggle should be OFF when guaranteed message delivery to both receivers is required 4 Reserv...

Page 17: ...l assign this value If an address is programmed and DHCP is used the address that you program will be used instead of the DHCP address Programming Options 010 System Toggle Options 3 1 Reserved 2 Visu...

Page 18: ...ue for your Time Zone Valid range is 00 FF Table 8 World Wide Time Zones HEX Value Offset Hours Std Abbrev Location 01 12 BIT Baker Island Time 05 11 NUT Niue Time SST Somoa Standard Time 09 10 HAST H...

Page 19: ...zilia Time UYT Uruguay Standard Time SRT Suriname Time ROTT Rothera Time PMST St Pierre Miquelon Standard Time GFT French Guiana Time 29 2 GST South Georgia and the South Sandwich Islands BEST Brazil...

Page 20: ...ime SCT Seychelles Time GST Gulf Standard Time SAMT Samara Time RET Reunion Time MUT Mauritius Time ICT Iles Crozet Time GET Georgia Standard Time AZT Azerbaijan Time 43 4 5 AFT Afghanistan Time 45 5...

Page 21: ...Time KRAT Krasnoyarsk Time WIB Waktu Indonesia Bagian Barat ICT Indochina Time BDT Bangladesh Standard Time 51 8 AWST Australian Western Standard Time CST China Standard Time HKST Hong Kong Standard T...

Page 22: ...9 10 AEST Australian Eastern Standard Time GST Guam Standard Time YAPT Yap Time VLAT Vladivostok Time TRUT Truk Time PGT Papua New Guinea Time DTAT District de Terre Adelie Time ChST Chamorro Standard...

Page 23: ...e configured to send Events in SIA or CID format The SIA communication format follows the level 2 specifications of the SIA Digital Communication Standard October 1997 This format will send the accoun...

Page 24: ...test transmission can be enabled or disabled in section 005 toggle option 7 Alternating Test Transmission with backup receivers Set Ethernet section 026 to FF 027 to 00 Interval 1 If the test transmi...

Page 25: ...nly if the panel becomes offline after a remote firmware update session has started 095 SA Incoming Local Port Default 0000 096 SA Outgoing Local Port Default 0000 097 SA Call Up IP Default 000 000 00...

Page 26: ...transmitters The account code is used when transmitting heartbeat signals to the central station receiver Signals received from the control panel will use the control panel account number Valid range...

Page 27: ...nge 000000 999999 minutes Once the unit has sent the initial periodic test transmission all future test trans missions will be offset by the programmed number of minutes See sections 026 029 NOTE Mini...

Page 28: ...re update process 25 System update pending communication in progress Retry in a few minutes if issue persists contact DSC Tech Support Firmware Update Sequence Change A0 System firmware update success...

Page 29: ...ed for DHCP and you need to see the IP address was assigned to the device by the DHCP Server This value is programmed in Section 007 or assigned by DHCP 989 DNS 2 IP Address This section will display...

Page 30: ...ler to refresh the unit after changes and also return the com municator to the default state 00 Default Module All programming sections in module revert to factory settings This will erase all existin...

Page 31: ...ng Options 010 System Toggle Options 3 ____ 1 Reserved ____ 2 Visual Verification Default OFF ____ 3 Reserved 011 Installer Code Default CAFE Valid range 0000 FFFF ____ ____ ____ ____ 012 DLS Incoming...

Page 32: ...r 1 UDP Local Port Default 0BF4 3060 Valid range 0000 FFFF ____ ____ ____ ____ 106 Ethernet Receiver 1 Domain Name Default 32 ASCII characters Programming not permitted on UL ULC listed system _______...

Page 33: ..._ ____ ____ ____ ____ ____ 991 Firmware Version ____ ____ ____ ____ ____ ____ ____ ____ 992 Ethernet IP Address ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ ____ 993 Ethernet Gateway Address...

Page 34: ...d in such a manner as to adversely affect performance or prevent adequate inspection or testing to verify any warranty claim Access cards or tags returned for replacement under warranty will be credit...

Page 35: ...des and this EULA and provided the recipient agrees to the terms of this EULA If the SOFTWARE PRODUCT is an upgrade any transfer must also include all prior versions of the SOFTWARE PRODUCT Terminatio...

Page 36: ...onsult the dealer or an experienced radio television techni cian for help The user may find the following booklet prepared by the FCC useful How to Identify and Resolve Radio Television Interfer ence...