Model EC-HS — 80 K-factor, Quick Response 

Extended Coverage Horizontal Sidewall Sprinklers 

Installations per VdS CEA 4001, Annex E, LH/OH1

Page 1 of 6 

AUGUST 2018 

TFP288

IMPORTANT

Refer to Technical Data Sheet 

TFP2300 for warnings pertaining to 

regulatory and health information.
Always refer to Technical Data 

Sheet TFP700 for the “INSTALLER  

WARNING” that provides cautions 

with respect to handling and instal-

lation of sprinkler systems and com-

ponents. Improper handling and 

installation can permanently damage 

a sprinkler system or its compo-

nents and cause the sprinkler to fail  

to operate in a fire situation or cause  

it to operate prematurely.

Worldwide 

Contacts

www.tyco-fire.com

General 

Description

The Model EC-HS, 80 K-factor, 

Extended Coverage Horizontal Side-

wall Sprinklers are extended coverage, 

decorative 3 mm glass bulb type spray 

sprinklers. They are to be installed per 

VdS CEA 4001 under smooth ceilings in 

Light or Ordinary Hazard 1, as well as in 

accordance with Annex E of VdS CEA 

4001 (e.g., commercial occupancies 

such as churches, restaurant seating 

areas, hotels, educational facilities, 

offices, etc.). With their coverage up to 

21 m

2

, they are designed for installa-

tion along a wall or the side of a beam 

and just beneath a smooth and level 

ceiling. Horizontal sidewall sprinklers 

are commonly used instead of pendent 

or upright sprinklers due to aesthet-

ics or building construction consider-

ations, where piping across the ceiling 

is not desirable.
The recessed version of the Model 

EC-HS Extended Coverage Horizontal 

Sidewall Sprinkler utilizes the Style 10 

Recessed Escutcheon with 13 mm of 

recessed adjustment or up to 19 mm 

of total adjustment from the flush side-

wall position, or a two-piece Style 20 

Recessed Escutcheon with 6 mm of 

recessed adjustment or up to 13 mm 

of total adjustment from the flush side-

wall position. The adjustment provided 

by the Recessed Escutcheon reduces 

the accuracy to which the fixed pipe 

lengths to the sprinklers must be cut.

NOTICE

The Model EC-HS Sprinklers described 

herein must be installed and maintained 

in compliance with this document and 

with the applicable standards recog-

nized by the Approval agency (VdS 

recognizes VdS EA4001), in addition 

to the standards of any other authori-

ties having jurisdiction. Failure to do so 

may impair the performance of these 

devices.
The owner is responsible for maintain-

ing their fire protection system and 

devices in proper operating condition. 

The installing contractor or sprinkler 

manufacturer should be contacted with 

any questions.

Sprinkler 

Identification 

Number

TY3330 -      EC-HS, 80K, 1/2 in. NPT