409-10042
DT-3000 Machines 1725100-[ ] and DT-5000 Machines 1725800-[ ]
Rev E
21 of 22
Tyco Electronics Corporation
7. Prepare the base plate for Air Feed Kit 1424266–1 (for Machines –2 and –3) as follows: install the
socket head screw and rear stop to the base plate, then remove the back left base plate clamp. Refer to
Figure 15.
8. Install the air feed applicator onto the base plate.
Figure 15
Base Plate for Machines -2 and -3
Clamps
Socket Head
Cap Screw
Rear Stop
Quick-Release T-Handle
9. Connect the air lines to the applicable ports as shown in Figure 16.
Air Feed Bracket
1338977-1
Large End of Air Feed
Cable Assembly 1424287-1
Four-Way Solenoid Valve
Slide Valve
Filter
Figure 16
Valve Lockout
Double-ActingAir Cylinder
SpringReturn
Air Cylinder Connection
Diode
Manual Override
Auxiliary Air
Connection
Manual Water Drain