409-10042
DT-3000 Machines 1725100-[ ] and DT-5000 Machines 1725800-[ ]
Rev E
16 of 22
Tyco Electronics Corporation
Figure 11
Lubrication Points
Lubrication Points
Precision Crimp Height
Adjustment Mechanism
6. ADJUSTMENTS
The following adjustments are necessary to maintain the machine in operating condition, and to set up the
machine after replacing parts.
To avoid personal injury, ALWAYS disconnect electrical and air supplies before performing adjustments.
6.1. Shut-Height Adjustment
The shut height is pre–set at the factory and should not require further adjustment unless it is necessary to
replace parts. In this case, and before making any changes to the machine, contact your local representative,
or call the Tooling Assistance Center at the number on the bottom of page 1.
Periodic inspection of the shut height by a field engineer is recommended.
The following information is for Field Service Engineer use only:
MACHINES
SHUT-HEIGHT GAGE
(408-8535)
SHUT HEIGHT
+0.025 mm [+.0010 in.]
(mm [in.])
-1, -4
679655-2
119.5 [4.705]
-2, -3, -6, -7
679655-3
135.79 [5.346]
-5
679655-2 with Adapter 1725684-1 or
679655-3 with Adapter 1725684-2
160.0 [6.299]
To avoid personal injury, ALWAYS turn off" the machine and disconnect the power supply to the machine before
making any adjustments. If applicator is an air-feed type, DISCONNECT air lines to valve located on the right side of
the machine.
DANGER
DANGER