background image

Instruction Sheet

Housing Removal Tool

408--8393

LOC B

1

of 2

E

2010 Tyco Electronics Corporation, Harrisburg, PA

All International Rights Reserved

TE logo and Tyco Electronics are trademarks.

*Trademark. Other products, logos, and company names used are the property of their respective owners.

TOOLING ASSISTANCE CENTER 1--800--722--1111

PRODUCT INFORMATION 1--800--522--6752

This controlled document is subject to change.

For latest revision and Regional Customer Service,

visit our website at

www.tycoelectronics.com

02 FEB 10 Rev A

1338744- 1

Figure 1

Insertion

Adjuster Rod

Socket Head

Screw

Side Push Bars

Screw

Clamp

Upper

Clamp

Lower

Clamp

1. INTRODUCTION

Housing Removal Tool 1338744--1 shown in Figure 1

is designed to remove the receptacle housing from a

6-- or 10--row Z--PACK* HM or HS3 backplane

receptacle connector on a printed circuit (pc) board.

The removal tool is designed for use in Pistol Grip

Manual Handle Assembly 58074--1. For set up and

operation of the manual hand assembly, refer to

instruction sheet 408--6790.

Dimensions on this instruction sheet are in metric

[with U.S. customary units in brackets]. Figures

are not drawn to scale.

Reasons for reissue of this instruction sheet are

provided in Section 7, REVISION SUMMARY.

2. DESCRIPTION

When properly inserted into the manual handle

assembly, the removal tool will clamp the receptacle

housing while removing it from the remaining part of

the connector. Features of the removal tool and their

functions are as follows:

Upper and Lower Clamps —

used to clamp the housing

into the removal tool.

Screw Clamp —

used to adjust the clamps for the

different housing sizes.

Insertion Adjuster Rod —

used to mount into the manual

handle assembly and to adjust stroke length.

Side Push Bars —

used to push on the pc board.

3. ADJUSTMENT

If the removal tool requires more travel to remove the

receptacle housing, remove the removal tool from the

manual handle assembly and turn the insertion

adjuster rod

counterclockwise

to increase the travel.

This setting is normally pre--set and will not need

adjustment.

4. HOUSING REMOVAL PROCEDURE

1. Select the connector that requires housing

removal.
2. Position the removal tool over the connector as

shown in Figure 2.
3. Using the screw clamp, close the upper clamp

onto the housing until the latches on the clamps

lock behind the front edge of the housing and the

connector is held firmly with the tool. See Figure 2.
4. Activate the manual handle assembly. This will

remove the housing from the remaining part of the

connector.
5. Loosen the screw clamp, and remove the

connector from removal tool.

Figure 2

Screw

Clamp

Clamp

Latch Front Edge

of Housing

Housing

NOTE

i

NOTE

i