TYAN GT24-B8236-IL Service Engineer'S Manual Download Page 1

 

     

 

 
 

 GT24-B8236-IL 

 
 

Service Engineer’s Manual 

 
 

 
 
 
 
 
 

 

 
 
 

Summary of Contents for GT24-B8236-IL

Page 1: ...GT24 B8236 IL Service Engineer s Manual...

Page 2: ...2 http www tyan com...

Page 3: ...s relating to fitness for a particular purpose or merchantability MiTAC retains the right to make changes to produce descriptions and or specifications at any time without notice In no event will MiTA...

Page 4: ...es and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in...

Page 5: ...oduction to the TYAN GT24 B8236 IL barebones standard parts list describes the external components gives a table of key components and provides block diagram of the system 2 Chapter2 Hardware Setup Co...

Page 6: ...the purpose of this pin If your outlet does not support this kind of plug contact your electrician to replace your obsolete outlet Do not place anything on the power cord Place the power cord where i...

Page 7: ...mbols on Equipment Caution This symbol indicates a potential hazard The potential for injury exists if cautions are not observed Consult equipment documentation for specific details Warning This symbo...

Page 8: ...nees bent Equipment Racks To avoid injury or damage to the equipment Observe local occupational health and safety requirements and guidelines for manual materials handling Do not attempt to move a rac...

Page 9: ...equipment on top of the unit It will cause restricted airflow and might cause damage to the equipment Make sure the product is properly matted with the rails Products that are improperly matted with...

Page 10: ...ace the battery only with a spare designated for your product Do not attempt to recharge the battery Dispose of used batteries according to the instructions of the manufacturer Do not dispose of batte...

Page 11: ...can become hot to the touch If the product sustains damage requiring service disconnect the product from the AC electrical outlet and refer servicing to an authorized service provider Examples of dam...

Page 12: ...12 http www tyan com...

Page 13: ...3 2 0 3 Tools 33 2 0 4 Precautions 34 2 1 Installing Motherboard Components 35 2 1 1 Removing the Chassis Cover 35 2 1 2 Installing the CPU and Heatsink 36 2 1 3 Installing the Memory 39 2 1 4 Install...

Page 14: ...n 66 3 8 Replacing the M1235 HDD Backplane 69 3 8 1 M1235 HDD Backplane Features 71 3 8 2 M1235 Connector Pin Definitions 73 3 9 Replacing the Power Supply 75 3 9 1 Replacing the M7016 Power Distribut...

Page 15: ...oviding a rich feature set and incredible performance and lightning fast PCI E bus implementation The GT24 B8236 IL not only empowers your company in nowadays IT demand but also offers a smooth path f...

Page 16: ...AC 100 240V Frequency 60 Hertz Power Supply Output Watts 500 Watts AMD 45nm 8 Core 12 Core Opteron 6100 Series Processors Magny Cours Supported CPU Series AMD 32nm 8 Core 12 Core 16 Core Opteron 6200...

Page 17: ...lash BIOS update Server Management AST2050 iKVM Feature 24 bit high quality video compression Dual 10 100 Mb s MAC interfaces Brand ROM size AMI 4MB BIOS Feature Plug and Play PnP PCI2 3 WfM2 0 SMBIOS...

Page 18: ...Power Supply Output Watts 500 Watts AMD 45nm 8 Core 12 Core Opteron 6100 Series Processors Magny Cours Supported CPU Series AMD 32nm 8 Core 12 Core 16 Core Opteron 6200 Series Processors Interlagos S...

Page 19: ...ssion Dual 10 100 Mb s MAC interfaces Brand ROM size AMI 4MB BIOS Feature Plug and Play PnP PCI2 3 WfM2 0 SMBIOS2 3 PXE boot ACPI 2 0 power management Power on mode after power recovery User configura...

Page 20: ...0 Series Processors Magny Cours Supported CPU Series AMD 32nm 8 Core 12 Core 16 Core Opteron 6200 Series Processors Interlagos Socket Type Q ty G34 2 Thermal Design Power TDP 115W Processor System Bus...

Page 21: ...ces Brand ROM size AMI 4MB BIOS Feature Plug and Play PnP PCI2 3 WfM2 0 SMBIOS2 3 PXE boot ACPI 2 0 power management Power on mode after power recovery User configurable H W monitoring Auto configurab...

Page 22: ...roduct should arrive packaged as illustrated below 1 4 1 Box Contents Component Description 1U chassis 4 hot swap HDDbays TYAN S8236 IL system board pre installed 500W single Power Supply 450W Power S...

Page 23: ...ervice http www tyan com The web site also provides information of other TYAN products as well as FAQs compatibility lists BIOS settings etc TYAN Motherboard Drive CD Heatsink x2 HDD Screw Pack Mounti...

Page 24: ...http www tyan com 24 1 6 About the Product The following views show you the product 1 6 1 System Front View...

Page 25: ...25 http www tyan com 1 6 2 System Rear View B8236G24V4H IL B8236G24W4H IL B8236G24W4HR IL...

Page 26: ...ed Blinking Green LAN active On Green LAN linked NIC3 off off LAN not linked On Red Fan fail Over temperature Over voltage Warning LED Off Off No failure On Blue System identified ID LED Off Off Syste...

Page 27: ...t identified HDD LED HDD Status Status LED 2 4 6 8 Color Amber Activity LED 1 3 5 7 Color Green No Driver Present or power disconnected OFF OFF No Activity OFF ON Driver Present Access Activity OFF Bl...

Page 28: ...tyan com 28 1 6 4 Motherboard S8236 IL Layout The diagram is representative of the latest board revision available at the time of publishing The board you receive may not look exactly like the above...

Page 29: ...J32 LAN3 Active LED Header J53 HDD Fault Header J59 IPMB Header JP1 JP2 COM2 Function Select Jumper JP3 Clear CMOS Jumper JP6 Front Panel ID LED Button JP7 Chassis Intrusion Header LED1 ID LED LED2 SA...

Page 30: ...http www tyan com 30 1 6 6 System Block Diagram...

Page 31: ...http www tyan com 31 1 6 7 Internal View B8236G24V4H IL B8236G24W4H IL 1 HDD Cage 2 M1235 HDD Backplane 3 System Fans 4 500W Power Supply 5 Memory Slots 6 CPU Sockets 7 PCI E Riser Card Assembly...

Page 32: ...http www tyan com 32 B8236G24W4HR IL 1 HDD Cage 2 M1235 HDD Backplane 3 System Fans 4 450W Power Supply x2 5 Memory Slots 6 CPU Sockets 7 PCI E Riser Card Assembly 8 M7016 Power Distribution Board...

Page 33: ...ts separated Putting all small components in separate containers prevents them from becoming lost Adequate lighting and proper tools can prevent you from accidentally damaging the internal components...

Page 34: ...any other grounded appliance Avoid touching motherboard components IC chips connectors memory modules and leads The motherboard is pre installed in the system When removing the motherboard always pla...

Page 35: ...install components on to the mainboard including CPUs memory modules and add on cards 2 1 1 Removing the Chassis Cover Follow these instructions to remove GT24 B8236 IL chassis cover 1 Unscrew the rea...

Page 36: ...CPU and Heatsink Follow the steps below on installing CPUs and CPU heatsinks 1 Locate the CPU socket 2 Pull the lever slightly away from the socket and then push it to a fully open position 3 Push the...

Page 37: ...an com 37 4 Take out the protection cap 5 Place the CPU into the socket and make sure that the gold arrow is located in the right direction 6 Close the CPU socket cover and press the lever down to sec...

Page 38: ...38 http www tyan com 7 Position the heatsink on top of the CPU and secure it with 2 screws 8 Repeat the procedures mentioned earlier to install the second CPU and heatsink...

Page 39: ...herboard 2 Press the memory slot locking levers in the direction of the arrows as shown in the following illustration 3 Align the memory module with the slot When inserted properly the memory slot loc...

Page 40: ...40 http www tyan com...

Page 41: ...1_DIMM 12 C1 CPU1_DIMM 13 B0 CPU1_DIMM 14 B1 CPU1_DIMM 15 A0 CPU1_DIMM 16 A1 NOTE 1 indicates a populated DIMM slot 2 Paired memory installation for Max performance 3 Populate the same DIMM type in ea...

Page 42: ...DR n a 1333MHz n a n a SR SR n a 1333MHz 1333MHz SR and DR n a n a 1333MHz 1333MHz SR and DR SR and DR n a n a 1600MHz SR and DR n a n a n a 1600MHz SR SR Notes U DIMM can support up to 4GB sized DIMM...

Page 43: ...n a 1333MHz SR DR and QR n a n a n a 1333MHz SR and DR SR and DR n a n a 1600MHz SR and DR n a n a n a 1600MHz SR SR Notes RDIMM can support up to 16GB sized DIMM s SR and DR Memory has a MAX amount o...

Page 44: ...stalling Hard Drives The GT24 B8236 IL supports four 3 5 hard drives Follow these instructions to install a hard drive 1 Press the locking lever latch and pull the locking lever open 2 Slide the HDD t...

Page 45: ...45 http www tyan com 4 Place a hard drive into the drive tray 5 Use 6 HDD screws to secure the HDD 6 Reinsert the HDD tray into the chassis and press the locking lever to secure the tray...

Page 46: ...rds The GT24 B8236 IL supports one PCI E expansion slot Follow these instructions to install the PCI E card 1 Unscrew the riser card bracket from the chassis 2 Lift the front edge of the riser card br...

Page 47: ...http www tyan com 47 3 Release the screws on both sides of the riser card bracket as shown 4 Remove the PCI E cover shields from the chassis 5 Insert the PCI E card in the direction of arrows as shown...

Page 48: ...48 http www tyan com 6 Screw the PCI E cards firmly to the riser card bracket...

Page 49: ...http www tyan com 49 7 Secure the riser card bracket to the chassis with two screws 8 The installation of PCI E expansion card is now complete...

Page 50: ...Ears including screws x 2 Screws Kit x 1 Mounting Brackets x 4 2 2 1 Installing the Server in a Rack Follow these instructions to mount the TYAN GT24 B8236 IL into an industry standard 19 rack NOTE B...

Page 51: ...om the supplied screws kit 2 Draw out the inner rails from rail assembly Install inner rails to left and right sides of chassis using 1 M4 4L A screw for each side 2 2 3 Installing the Outer Rails to...

Page 52: ...on rear bracket Secure the rear bracket to outer rail with 2 M4 4L A screws 5 Secure the outer rail to the rack using 2 brackets and 4 M5 8L B screws for each side Secure the mounting brackets from in...

Page 53: ...e chassis in and press the latch key A Then push the whole system into the rack B 4 Secure the mounting ears of chassis to the rack with 2 M5 15L C screws NOTE To avoid injury it is strongly recommend...

Page 54: ...http www tyan com 54 NOTE...

Page 55: ...ncluding the Motherboard M1008 LED control board M1235 HDD Backplane M2091 M2091 R PCI E Riser card System fan ODD drive Power supply unit etc 3 2 Disassembly Flowchart The following flowchart outline...

Page 56: ...http www tyan com 56 Front Components Chassis cover DVD ROM optional PCBs FAN M1008 LED Control Board M1235 HDD Backplane M7016 Power Distribution Board...

Page 57: ...B8236 IL 3 4 Replacing Motherboard Components Follow these instructions to replace motherboard components including the motherboard 3 4 1 Replacing Expansion Card The GT24 B8236 IL has two preinstalle...

Page 58: ...58 http www tyan com 2 Unscrew the M2091 riser card 3 Unscrew the M2091 R riser card 4 Install a new riser card onto the bracket following the procedures mentioned earlier in reverse order...

Page 59: ...All Motherboard Cables Before replacing the motherboard or certain components remove cables connected to the motherboard Follow these instructions to remove all motherboard cables 1 Disconnect all po...

Page 60: ...l of the aforementioned cables follow the instructions below to remove the motherboard from the chassis 1 Remove the heatsinks and processors if installed 2 Remove the nine screws securing the motherb...

Page 61: ...llow these instructions to replace the slim DVD ROM 1 Remove the power and data cable from the slim DVD ROM adapter 2 Press the tab in the directions as shown to release the DVD ROM drive 3 The DVD RO...

Page 62: ...ables from the DVD ROM drive 5 Remove two screws that secure DVD ROM drive to the bracket 6 Replace the DVD ROM drive 7 Secure DVD ROM to the bracket using two screws Then replace the unit into the dr...

Page 63: ...Board Follow these instructions to replace the M1008 LED control board 1 Remove the two screws securing the LED control board unit to the chassis 2 Push the LED control board unit out and unplug the...

Page 64: ...ove three screws securing the LED control board to the bracket 4 Lift the LED control board free from the chassis After replacing the LED control board insert the unit into the chassis following the a...

Page 65: ...tion J1 USB Header Definition Pin Pin Definition VCC 1 2 VCC USB1 3 4 USB2 USB1 5 6 USB2 GND 7 8 GND Key 9 10 GND J3 SSI Definition Pin Pin Definition PW_LED 1 2 VCC KEY 3 4 ID_LED PW_LED 5 6 ID_LED H...

Page 66: ...em Fan Follow these instructions to replace the cooling fans in your system 1 Locate the cooling fans in your system 2 Unplug the cables connected to the mainboard and lift the fan unit up from the ch...

Page 67: ...67 http www tyan com 40x28mm Fan Step A Step B 4 Follow Step C D to take out the old fan and replace with a new one 40x28mm Fan Step C Step D...

Page 68: ...follow Step A B in reverse order to lock the fans Reinstall the fans into the chassis 6 Connect the fan cables to the backplane fan connectors System Fan to M1235 System Fan Connect to M1235 Fan1 Fan...

Page 69: ...9 3 8 Replacing the M1235 HDD Backplane 1 Disconnect the power cables connected to the HDD Backplane 2 Disconnect the Mini SAS cable and the fan cables 3 Remove the three screws securing the bracket t...

Page 70: ...Backplane and reinstall it into the chassis following the steps mentioned earlier in reverse M1235 SATA SAS Backplane to S8236WGM3NR Cable SATA SAS BP Board Connect to S8236 MB Mini SAS Cable J39 J17...

Page 71: ...71 http www tyan com 3 8 1 M1235 HDD Backplane Features M1235 Front View PW1 J7 Fan Header PW2 J42 J18 J45 J41 SGPIO J39 Mini SAS Connector J40 FAN6 FAN5 FAN4 FAN3 FAN2 FAN1 FAN7 J43 J15 CPLD_JTAG...

Page 72: ...http www tyan com 72 M1235 Rear View J14 HDD3 J13 HDD2 J11 HDD1 J10 HDD0 LED2 LED1 LED4 LED3 LED6 LED5 LED8 LED7...

Page 73: ...tion GND 1 2 GND 12V 3 4 12V J15 SGPIO JTAG Definition Pin Pin Definition TCK 1 2 GND TDO 3 4 3 3V TMS 5 6 NI NI 7 8 KEY TDI 9 10 GND J41 SGPIO for IOH Definition Pin Pin Definition SM_CLK 1 2 SGPIO_0...

Page 74: ...74 http www tyan com J40 PWM select for system FAN3 Pin Definition 1 CPU_PWM 2 PWM_12 FAN3 3 CPU_PWM2 Note Pin 1 2 chose by CPU_PWM Default Pin 2 3 chose by CPU_PWM2...

Page 75: ...com 75 3 9 Replacing the Power Supply B8236G24V4H IL B8236G24W4H IL 1 Disconnect the power cables from the motherboard and the M1235 PSU to M1235 Backplane BP Board PSU Connect to M1235 2x2P PWR P3 P...

Page 76: ...tp www tyan com PSU to S8236 IL MB Power Supply Unit PSU Connect to S8236 IL 2x12P PWR P1 J18 2x4P PWR P2 J26 2x4P PWR P7 J52 PSMI P8 J31 2 Remove nine 9 screws that secure the power supply to the cha...

Page 77: ...77 http www tyan com 3 Remove the power supply bracket and then slide out the whole power supply unit...

Page 78: ...78 http www tyan com 4 Install a new power supply unit following the steps in reverse...

Page 79: ...M7016 Power Distribution Board B8236G24W4HR IL 1 Press the latch to pull the two power supplies out 2 Disconnect the cables from the M7016 power distribution board 3 Remove six 6 screws that secure th...

Page 80: ...tribution Board Pin Definitions ATX1 Definition Pin Pin Definition GND 1 2 GND GND 3 4 GND 12V2 5 6 12V2 12V3b 7 8 12V3b ATX2 Definition Pin Pin Definition GND 1 2 GND GND 3 4 GND 12V1 5 6 12V1 12V3a...

Page 81: ...5VSB 9 10 12V 12V 11 12 3 3V 3 3V 13 14 12V GND 15 16 PS_ON GND 17 18 GND GND 19 20 Reset 5V 21 22 5V 5V 23 24 GND PW2 PW3 Definition Pin Pin Definition 12V 1 2 GND GND 3 4 5V PW4 Definition Pin Pin...

Page 82: ...82 http www tyan com 3 10 Replacing the Redundant Power Supply B8236G24W4HR IL 1 Located the power supply cage 2 Press the latch to pull the power supply out...

Page 83: ...83 http www tyan com 3 After replacing a new power supply press and hold the latch to push the power supply back into the chassis...

Page 84: ...84 http www tyan com NOTE...

Page 85: ...235 Fan1 FAN1 Fan2 FAN2 Fan3 FAN3 Fan4 FAN4 Fan5 FAN5 Fan6 FAN6 2 SATA HDD Cable M1235 SATA SAS Backplane BP Board to S8236 MB Cable M1235 Connect to S8236 IL MB Mini SAS Cable J39 J20 Fan cable J7 J2...

Page 86: ...X4P PWR cable 1 J52 PDB ATX2 2X4P PWR cable 2 J26 PDB PW1 2X12P PWR cable J18 PDB J14 PSMI cable J31 M7016PDB to M1235 Backplane BP Board M7016 Connect to M1235 PDB PW3 B4P cable BP PW1 PDB PW4 2X2P B...

Page 87: ...Top Cover CCCV 0180 34078090001 1 GT24 Top Cover Chassis Front Bezel CFBZ 0070 541273910008 1 Front Bezel for GT24 Series 1UChassis HDD Tray 340782800009 4 3 5 HDD Tray Power Supply CPSU 0520 47110000...

Page 88: ...50 340740900010 1 Mounting Ear Kit CCBL 072R 422780900001 1 Control Cable 800mm CCBL 035O 422791600002 1 USB2 0 Cable 650mm 422794700001 1 FAN Control Cable 350mm CCBL 067O 422784300005 1 Mini SAS to...

Page 89: ...uch as in depth Linux Online Support sections with downloadable Linux drivers and comprehensive compatibility reports for chassis memory and much more With all these convenient resources just a few ke...

Page 90: ...per maintenance of products Note A receipt or copy of your invoice marked with the date of purchase is required before any warranty service can be rendered You may obtain service by calling the manufa...

Reviews: