Page 1: ...OWNERS MANUAL...
Page 2: ...nce with the manufacturer s instructions 8 Do not install near any heat sources such as radiators heat registers plugs and the point where they exit from the apparatus 9 Protect the power cord from be...
Page 3: ...ncies are allowed to pass to the gain stage When the knob is in the out position the low and low mid frequencies are boosted This is a low frequency contour switch changing the low and low mid respons...
Page 4: ...applied to the reverb unit Low settings will provide a smooth short decay effect simulating small to medium rooms Higher settings will increase the decay time At maximum clockwise rotation an extreme...
Page 5: ...ses are 3AG Type 250 Volt SLO BLO Export 100 Volt Domestic Fuses Export 220 230 240 Fuses 2A 22 35 Watt 2A 22 35 Watt 1A 22 35 Watt 2 5 50 Watt 2 5 50 Watt 1 6 50 Watt 3 2 100 Watt 3 2 100 Watt 2 5 10...
Page 6: ...unit and connect proper speaker load DO NOT have an instrument connected to the input during the biasing procedure Take unit off standby and allow a few seconds for the circuit to stabilize Set multi...
Page 7: ...o bias must not be set higher then 044V as it will cause tube failure Do not set bias higher then recommend levels as it can lead to tube failure or failure within the amplifier amplifiers are brought...