Twinno T6000 Operating Manual Download Page 1

Shanghai Chunye Instrument Technology Co.,Ltd

Tel: 021-61621082 
Fax: 021-61621099 
Web: www.twinno.net  
Add: Building 6, No.166 Mindong Road, Pudong New District, Shanghai, China 
Post code:201209

T6000 pH/ORP Online Analyzer

Operating Manual

Shanghai Chunye Instrument Technology Co.,Ltd

Summary of Contents for T6000

Page 1: ... Co Ltd Tel 021 61621082 Fax 021 61621099 Web www twinno net Add Building 6 No 166 Mindong Road Pudong New District Shanghai China Post code 201209 T6000 pH ORP Online Analyzer Operating Manual Shanghai Chunye Instrument Technology Co Ltd ...

Page 2: ...ment is not suitable for use in harsh environment high temperature low temperature or strong magnetic field interference which may lead to instrument damage ӹ If there is any problem with the instrument please contact the dealer or the company Do not disassemble the instrument by yourself If disassembled the company will no longer be responsible for the warranty Cautions Table of Contents Preface ...

Page 3: ...vides specified measurements 3 The analyzer has been stored for a long time in an environment where the temperature exceeds 70 The analyzer must be installed by professionals in accordance with relevant local specifications and instructions are included in the operation manual Comply with the technical specifications and input requirements of the analyzer 22 Complete Set We Instruments warrants th...

Page 4: ...vaded into the 3 3mkcl solution for activation Do not touch it by hand To ensure long term accurate measurement the electrode should be cleaned maintained and calibrated regularly Antimony electrode will be oxidized after a period of time and the electrode head will be black Fine sandpaper can be selected to polish the electrode head and remove the oxidation part to ensure the sensitivity of elect...

Page 5: ... 4 00 4 01 4 01 4 02 4 03 4 04 4 06 4 08 4 10 4 12 4 16 4 20 pH6 86 6 98 6 95 6 92 6 90 6 88 6 86 6 85 6 84 6 84 6 83 6 83 6 83 6 84 6 85 6 86 6 88 pH9 18 9 47 9 38 9 32 9 27 9 22 9 18 9 14 9 10 9 07 9 04 9 01 8 99 8 96 8 92 8 89 8 85 pH4 00 4 01 4 00 4 00 4 00 4 00 4 00 4 01 4 02 4 03 4 04 4 06 4 07 4 09 4 12 4 16 4 20 pH7 00 7 12 7 09 7 06 7 04 7 02 7 00 6 99 6 98 6 97 6 97 6 97 6 97 6 98 6 99 7...

Page 6: ...es Examples of function code 04 instructions Communication address 1 temperature 20 0 ion value 10 0 temperature voltage 100 0 ion voltage 200 0 Host Send 01 04 00 00 08 F1 CC Slave Response 01 04 10 00 41 A0 00 41 20 00 42 C8 00 43 48 81 E8 Note 01 Represents the instrument communication address 04 Represents function code 04 10 represents 10H 16 byte data 00 00 00 41 A0 20 0 temperature value 00...

Page 7: ...s 0x00 2 If the compiler used by the user does not implement the library function of this function the following functions can be used to achieve this function void memcpy void dest void src int n char pd char dest char ps char src for int i 0 i n i pd ps And then make a call to the above memcpy outdata floatdata 4 Example Compile binary floating point number 0100 0010 0111 1011 0110 0110 0110 10B...

Page 8: ...ssa 0 10000011 00011010000000000000000B the hexadecimal system is shown as 0 x418d0000 Reference code 1 If the compiler used by the user has a library function that implements this function the library function can be called directly for example using C language then you can directly call the C library function memcpy to obtain an integer representation of the floating point storage format in memo...

Page 9: ...fies the value of the registers written in the request data frame Data is packaged in two bytes per register Response frame return function code start address and number of registers written Request N Register number Figure11 Write multiple register request frames Response N Register number Figure 12 write multiple register response frames The request frame and response frame are illustrated below...

Page 10: ...s 1 byte 1 byte N 2 byte 0x03 N 2 Request Frame Number Systems Function code Start address high byte Start address low byte Number of Read Registers High Bytes Number of Read Registers Low Bytes Hexadecimal 0x03 0x06 0x02 0x2B 0x00 0x00 0x00 0x64 Hexadecimal 0x03 0x00 0x6B 0x00 0x03 Response Frame Number Systems Function code Byte count Register Value High Bytes 108 Register Value Low Bytes 108 Re...

Page 11: ...contains two 4 bit hexadecimal characters 0 9 A F Bits in each byte 1 starting bit 8 data bits the first minimum valid bits without parity check bits 2 stop bits Baud rate 9600 BPS How characters are transmitted serially Each character or byte is sent in this order from left to right the least significant bit LSB Maximum Significant Bit MSB Figure 3 RTU pattern bit sequence Check Domain Structure ...

Page 12: ...atically identifies the standard liquid first calibrates the midpoint example 7 00pH then calibrates 4 01pH or 10 01pH The corresponding mV value will be displayed on the left side of the screen After the calibration is completed the offset and slope will be displayed on the right side of the screen If only two points of calibration are needed after two points of calibration press theսMenuվ button...

Page 13: ...rrect the data Offset adjustment Compare the data of laboratory or portable instrument with the data of instrument measurement if there are errors the error data can be modified by this function Linear adjustment Linear values after field calibration are stored in this item with factory data of 1 00 Calibrating 12 Press theսMenuվbutton returns to the measurement screen Press theսӜ TRENDվ button in...