background image

 

 

 

TS-1800 Site Preparation 

 

 

Revision 1.1 
July, 2020 
 
Twine Solutions Ltd 
www.twine-s.com 
 

© 2019 Twine Solutions Ltd. All rights reserved. 

This document and the information contained herein is CONFIDENTIAL to TWINE Solutions Ltd, and shall not be used, 
published, disclosed, or disseminated outside TWINE in whole or in part without TWINE's consent. This document 
contains TWINE trade secrets. Reverse engineering based on any of the information in this document is prohibited. 

This copyright notice does not imply publication of this document. 

This document shall not be circulated in part or whole outside TWINE. 

 

Summary of Contents for TS-1800

Page 1: ...TWINE Solutions Ltd and shall not be used published disclosed or disseminated outside TWINE in whole or in part without TWINE s consent This document contains TWINE trade secrets Reverse engineering...

Page 2: ...3 Circuit Breaker 10 6 4 Residual Current or Earth Leakage Device 11 7 Network 12 7 1 Network Connections 12 8 Environmental Conditions 13 8 1 Temperature Humidity and Altitude 13 8 2 Air Quality 13...

Page 3: ...mer is responsible for Preparing the site as described in this document Complying with all applicable local regulations Filling out and signing the Site Preparation Checklist Sending the Site Preparat...

Page 4: ...and abbreviations are used throughout this document Term Abbreviation Definition A Ampere AC Alternating Current ASL Above Sea Level C degrees Celsius or Centigrade F degrees Fahrenheit ft feet kg kil...

Page 5: ...ingle stand alone unit as shown in the figure below Figure 1 TS 1800 Digital Thread Dying System 3 1 Size and Weight The TS 1800 has the following main dimensions and weight Length L 2 0 meters 79 inc...

Page 6: ...TS 1800 Site Preparation Guide Page 6 Figure 2 TS 1800 dimensions definition...

Page 7: ...n unpacking area must be available The area must enable sufficient clearance to lift the machine pallet and to unload the machine from the pallet 4 4 Transporting the System in a Building Before enter...

Page 8: ...s to ensure that the TS 1800 can be lifted to the required floor level The installation area should be free of sources of vibration and electromagnetic interference that might affect the proper functi...

Page 9: ...r plan is shown below with the TS 1800 placed in a likely operating area The dimensions shown in the figure are minimum clearance requirements Note The floor where the machine is located should be non...

Page 10: ...USA or any 110V power Grid If the power Grid cannot supply min 220V The machine must connect to Transformer Transformer Input 208V 20Am Transformer Output 220V 240V 20Am If the power at your facility...

Page 11: ...ocket that is connected through a residual current or earth leakage device 6 5 Power cable The Power cable cord that supply with the machine is without power plug in order to made worldwide compatibil...

Page 12: ...ted in an area with access to a strong Wi Fi signal and connected to the network via a LAN communication connection Min Internet Speed 40mb Port 80 1080 and Port 443 must be open outside in order to e...

Page 13: ...ing temperature 10 C to 30 C 50 F to 86 F Non operating temperature 5 C and 50 C 41 F and 122 F Relative humidity 20 to 60 Operating altitude must be 3000m ASL 8 2 Air Quality The TS 1800 should be lo...

Page 14: ...fire 9 3 Cleaning the System All parts of the system can be cleaned using one the following materials Isopropyl alcohol technical grade Ethanol 99 9 technical grade We recommend keeping a gallon of on...

Page 15: ...red upright on trays Keep the temperature of the storage area between 5 C and 50 C 41 F and 122 F Ensure that the humidity range of the storage area falls between 10 and 70 Ink cartridges may be used...

Page 16: ...you have any questions consult your Twine representative 11 1 Customer Details Company name Company address Company telephone no Company email address 11 2 Site Preparation Checklist Item Meets Requir...

Page 17: ...ge 17 Item Meets Requirements Notes Yes No Ventilation Fire extinguisher I understand that non compliance with the requirements specified in this document may result in additional installation charges...

Reviews: