Summary of Contents for OpenSky IoT NEMA

Page 1: ...MA IoT Installation Manual PR166201 English Copyright Tvilight B V PR 00 1662 01 Rev C 13 11 2020 TVILIGHT PROJECTS BV Beechavenue 162 180 1119 PS Schiphol Rijk the Netherlands info tvilight com www tvilight com ...

Page 2: ...onnected to a dimmable driver ballast NOTE Some dimmable drivers ballasts must be programmed set to dimmable mode Also select the correct configuration i e 0 10V or DALI from the CMS If this has not been done OPENSKY NEMA IoT will not be able to dim the connected armature DALI logarithmic dimming mode is recommended ...

Page 3: ...t 230 V AC Output 0 10V DALI SR D4I RF EGPRS LTE Cat M1 Cat NB2 ta 40 C 70 C Nema IoT NEMA OLC device comes with two Bar Code labels 1 Please stick one label on the street light luminaire 2 Please stick the second label on the street pole preferably inside the junction box Bar Code needs to be scanned once using Tvilight Scan Go App please see the instructions below ...

Page 4: ...CityManager The Device Name OpenSky NEMA IoT Serial Number Bar Code UID and Comments can be added manually The Device Serial Number can also be added using the Scanner function which is activated by tapping the camera icon in the app For more information on how to use Scan Go app please visit https www tvilight com scan go To create your user account please email support tvilight com Please add yo...

Page 5: ...light com 1 If applicable twist to release protective cap 2 If applicable remove protective cap WARNING TURN THE POWER OFF AT THE CIRCUIT BREAKER BEFORE INSTALLING THE DEVICE Ensure the device is pre registered in Tvilight CMS at the factory ...

Page 6: ... IoT on receptacle 4 Twist OPENSKY NEMA IoT to lock it in place Install the device with the transparent window facing the NORTH direction Adjust the receptacle position if necessary Ensure the transparent window on the dome is free of any obstruction for at least 5 feet ...

Page 7: ...ire Wiring reference is as below Notes 1 Through the transparent window a RED and GREEN LED are visible 2 For added protection it is recommented to add an external circuit breaker at the power input of the product Circuit breakers such as the ELeQ LS 94 5L2408 or similar rated products could be used 3 For regions with unclean fluctuating electric grids which are prone to voltage surges Tvilight st...

Page 8: ...y and the OLC location So please have patience 6 The device should now be online on CMS and the green LED will turn to solid green The device should now be online on CMS 7 Use your login same as Scan Go app or other user account provided by Tvilight Support Desk to login to the CityManager CMS https tvilight io 8 You are ready and connected Enjoy energy savings and smart maintenance notifications ...

Page 9: ...device location Please note that the sim connection can take as much as 8 hours when used for the first time in your region 3 If the above steps did not resolve the issue then please contact Tvilight support desk support tvilight com 3 Tried everything faulty device We are very sorry Please contact support tvilight com for further instructions and send the device for RMA replacement Further suppor...