background image

5.3 

Control via RS-232 Option 

Using appropriate control codes, it’s possible to switch any input to any output under 
control of a computer or other hardware control device. To use this functionality, first 
prepare a control cable by reference to the table below. Make certain that you have 
continuity between the pins as shown. 

The RS-232 control connections are as follows: 

MX-5288

 

 

Controller 

Pin Number

 

Function

 

Pin Number

 

Function 

1

 

NC

 

 

1

 

NC 

2

 

Tx

 

 

2

 

Rx 

3

 

Rx

 

 

3

 

Tx 

4

 

NC

 

 

4

 

NC 

5

 

GND

 

 

5

 

GND 

6

 

NC

 

 

6

 

NC 

7

 

NC

 

 

7

 

NC 

8

 

NC

 

 

8

 

NC 

9

 

NC

 

 

9

 

NC 

 

 

RS-232 transmission format: 

Baud Rate: 9600 bps 
Data bit: 8 Bits 
Parity: None 
Stop Bit: 1 bit 
Flow Control: None 
 
The RS-232 control codes used by the MX-5288 are as follows: 
 

ASCII Code

 

Meaning 

VR

 

Displays Firmware Version 

INx (eg IN1)

 

Input 1 through 8 

IN0 (Zero)

 

“Muted” Input 

OUTx (eg OUT1)

 

Output 1 through 8 

ALL

 

All Outputs 

>

 

Routing Indicator 

 

CODE EXAMPLES: 

“IN1 > OUT3”   [Route Input 1 to Output 3] 
“IN1 > ALL”   [Route Input 1 to ALL Outputs] 
“IN0 > OUT2”  [Mute Output 2] 
 

NOTE: Full command lines must be followed by an ASCII Carriage Return[0x0D] for the command to be processed. 

 

 

 

Summary of Contents for MX-5288

Page 1: ...Instruction Manual MX 5288 8x8 DVI D Matrix Switcher ...

Page 2: ...ntroduction 2 2 0 Specifications 3 3 0 Checking Package Contents 4 4 0 Connecting The Hardware 4 5 0 Operating The Unit 5 6 0 Troubleshooting 13 7 0 Limited Warranty 14 8 0 Regulatory Compliance 15 9 0 Contact Information 15 ...

Page 3: ... 1 1 Liability Statement Every effort has been made to ensure that this product is free of errors tvONE cannot be held liable for the use of this hardware or any direct or indirect consequential damages arising from its use It is the responsibility of the user of the hardware to check that it is suitable for his her requirements and that it is installed correctly All rights reserved No parts of th...

Page 4: ...tons Remote Control IR RS 232 and Ethernet Warranty Limited Warranty 3 Years Parts and Labor Mechanical Size H W D Standalone Weight Net 44x440x200mm 1 75 x17 x7 9 3 27 kg 7 2 lbs Size H W D w Rackmount Kit 44x482x200mm 1 75 x19 x7 9 Environmental Operating Temperature Operating Humidity 0 to 40 C 32 to 104 F 20 to 90 Non condensing Storage Temperature Storage Humidity 20 to 60 C 4 to 140 F 20 to ...

Page 5: ...place the unit on a flat surface that offers security and accessibility Insure that there is adequate ventilation and make sure that there is access to the rear and front panels Ensure that the MX 5288 power switch is in the Off position and turn off any equipment that will be part of the installed system Next connect the input and output cables as required When you plug in the cables connect them...

Page 6: ...on a Lock button and a button labeled All Using these buttons you can control all switching actions possible with the MX 5288 These actions are described below To select one input and one output select the input first and then the output Both buttons will light up and when you press the Take button the selected path will be completed from the input to the output To cause one input to appear on mul...

Page 7: ...u from making changes to paths that are critical There is a function called Group Selection which allows you to split the 8 inputs and 8 outputs into combinations of single and multiple paths For example you could select source 1 and destination output 2 then source 2 and destinations 3 and 4 Next you could select source 3 and set its output path to destination 5 After making these selections you ...

Page 8: ...sections of selector buttons that can be used to control the MX 5288 NOTE The front panel buttons will not light up when using the IR remote to control the unit Normal matrix functions are performed by pressing the numbered button of the input you wish to route from the two rows of INPUT buttons followed by pressing the numbered button s of the desired output s from the two rows of OUTPUT buttons ...

Page 9: ...C 1 NC 2 Tx 2 Rx 3 Rx 3 Tx 4 NC 4 NC 5 GND 5 GND 6 NC 6 NC 7 NC 7 NC 8 NC 8 NC 9 NC 9 NC RS 232 transmission format Baud Rate 9600 bps Data bit 8 Bits Parity None Stop Bit 1 bit Flow Control None The RS 232 control codes used by the MX 5288 are as follows ASCII Code Meaning VR Displays Firmware Version INx eg IN1 Input 1 through 8 IN0 Zero Muted Input OUTx eg OUT1 Output 1 through 8 ALL All Output...

Page 10: ...he matrix switch by either RS 232 or Ethernet connection There are three primary sections of the control software interface the toolbar at the top the input selection area on the left and the output selection area on the right The input and output selections are intuitive The Toolbar details are explained below Input Selection Area Output Selection Area Toolbar Menu ...

Page 11: ...et control NOTE After making changes to the Ethernet settings the user must power cycle the unit for the new settings to become effective If the unit receives commands from both Ethernet and RS 232 ports at the same time the Ethernet commands will have priority Scan The Scan button brings up the Serial Port Scan menu which allows the user to scan the computer s COM ports for connected units The Se...

Page 12: ...n Area on the left side to send that Input to all Outputs Choose the Unselect All Output menu item to de select all currently selected Outputs from the currently selected Input Choose one of the Select Input n menu items to make that Input your active input Then select all of the Outputs you wish to send that Input to from the list of Outputs in the Output Selection Area on the right side Fast Sel...

Page 13: ...t and select the Input to route to it The connection line will move to indicate the new route To route an Input to more than one Output select the Outputs you wish to affect in the Output Selection Area on the right each button will turn grey to indicate it is selected After you have selected all of the Outputs you wish to affect select the Input you wish to send to those Outputs from the buttons ...

Page 14: ...e problem moves If it does the problem is with the source As a final step before contacting technical support use the Web GUI to perform a system reset will return the unit to the default settings Note It is strongly recommended that you use premium cables in order to achieve maximum distance cable runs and the best performance possible After trying the above suggestions should the problem still p...

Page 15: ...arts replaced become the property of tvONE This warranty does not apply to those products which have been damaged due to accident unauthorized alterations improper repair modifications inadequate maintenance and care or use in any manner for which the product was not originally intended If repairs are necessary under this warranty policy the original purchaser must obtain a Return Authorization Nu...

Page 16: ...82 8225 sales tvone com www tvone com tvONE Europe Continental Approach Westwood Industrial Estate Margate Kent CT9 4JG UK Tel 44 0 1843 873311 Fax 44 0 1843 873312 sales europe tvone com tvONE Latin America 6991 NW 82 Avenue 8 Miami FL 33166 USA Tel 305 396 6275 Fax 305 418 9306 sales latinoamerica tvone com tvONE Mercosur Av Diaz Velez 3965 PB Capital Federal 1200 Buenos Aires Argentina Tel 54 1...

Reviews: