9.4 Save All Settings
During operation the unit can be asked to store the current complete setup in non volatile
memory. The user performs this by pressing the
Save All Settings
at the top of the
screen. The user is asked to confirm this action. If accepted the unit copies all the
settings. This will take some time.
On power up the unit will retrieve all the settings and configure the unit to that when the
Save all settings is pressed. Due to the time to read this information the start up time of
the unit is significantly increased.
For systems which are not due to be left alone it is often better to store the setups on the
dedicated PC and to use the local data in the login screen to load the unit form the PC.
This provides greater flexibility and a faster start up.
9.5 Comm Data
Under normal use the user does not need to worry about the Comm Data tab. However if
a communication fault should occur the tab background will change color. If this occurs
the user can open this tab and investigate what may be causing a problem.
This screen lists all the commands sent to the unit and information returned. A time stamp
is used at the beginning of each line to help work out when commands are sent. The most
recent command is shown at the top.
The user can also send individual commands from the command line at the bottom. The
data is all stored and can be saved as a simple text file. This is designed to help resolve
any customer issue where a log report can be sent to TVOne that can greatly identify what
may be reported as a fault. A complete log from start-up can also be used to duplicate
actions on a similar machines.
9.6 Logging Out
The user may log out at any time. All the main screens have a button in the top right
market Logout. When this is clicked the unit offers the chance for the user to save all the
current settings on the PC for working off line for recalling at a later login. The user should
use a suitable name.