Wi-Fi Smart Combustible Gas Alarm Manual

 

Product Review:

This product is a WiFi flammable gas alarm, which is used to detect the leakage of  flammable gas and prevent the harm 
caused by gas leakage. The alarm uses high stability semiconductor gas sensor, which has the characteristics of high 
stability and small sensitivity drift. When a flammable gas leak is detected and the concentration value set by 
the alarm is reached, the alarm will send an alarm signal. This product is used indoor where leakage may occur, such as 
kitchens.
Before installation, please confirm the detecting gas density heavier or lighter than air. If detecting gas is heavier than air: 
LPG. etc, install at 0.3-1m height from floor, semi-diameter to gas source less than 1.5m. If detecting gas is lighter than 
air: nature gas, manufactured gas, marsh gas, etc, install at 0.3-1m height from ceiling, semi-diameter to gas source less 
than 1.5m. 

Specification:

Working Voltage: AC 85V-250V
Average Consumption: ≤1.5W
Alarm Sound:  70dB/m
Alarm Density:6%LEL ± 3%LEL

CH4

WIFI Standard: 802.11b/g/n
Working Temperature: -10 ~ +50

Working Humidity:≤95%RH

How to use:

1. Download Tuya Smart APP, or scan the QR 
code below to download

2. Insert the gas detector into socket, starting 
network configuration automatically, Green 
LED flashes quickly. 
* If the network is not configured, only the green LED is on. After the network is successfully configured, 
the three-color LED blinks alternately. LED will be in Green before Warm up finish. It will take 5 minutes to warm up.

3. Use the mobile phone number to register 
the APP to log in, click "+" on the "My Home" 

screen or click "Add Device" in the middle 
blank, select security sensor, and click on the 
gas sensor (WiFi)

4. When Power on, the green indicator does 
not flash quickly, use the pin to press the 
RESET button for more than 5 seconds, the 

indicator flashes quickly, means starting 
network configuration automatically. Input 
"WIFI password" in the APP according to the 
prompt, and click ENTER.

Reviews: