Tutco-Farnam Heat Torch 050 Quick Manual Download Page 1

Heat Torch

TM

 050

 

Quick Guide

 

www.farnam-custom.com 

Heat Torch

TM

 050

 

Quick Guide

 

Product Description 

Tutco-Farnam’s Heat Torch

TM 

 inline air heaters are ideal for 

rapidly heating air. Industrial strength open coil heaters provide 
efficient heat transfer through direct heating element contact 
with the airflow 

Operation 

To operate this heater, ensure air is flowing and ener-
gize the main supply disconnect. Set the controlling 
device to the desired temperature.  

During initial heating, it is recommended to slowly 
ramp up the process set point and inspect the heating 
system for problems. 

DO NOT 

operate the heater at voltages higher than the 

recommended use. 

DO NOT 

operate the heater at flow rates below the 

minimum flow range (1 SCFM)—reduced flow can 
shorten heater life. 

Supply clean, dry air to the heater at a max of 120 psi . 

CAUTION 

Tutco-Farnam Custom Products recommends 
installation be performed by qualified personnel 
familiar with the National Electrical Code and all 
local codes and standards. It is the responsibility 
of the installer to verify the safety and suitability 
of the installation. 

Failure to follow Tutco-Farnam’s recommenda-
tions could result in premature failure, serious 
equipment damage, injury or death. 

WARNING 

DO NOT

 mount heaters in an atmosphere containing combustible gases, 

vapors, dusts or fibers. 

Hazardous voltages are present in this equipment. Lock out and tag the 
branch circuit disconnect switch before working on this heater. 

Exterior of heater at exhaust is approximately the air temperature. Treat the 
exterior of the heater as a burn hazard.

 

Typical causes for uneven airflow are structural components blocking air or 
mounting the heater too close to elbows, transitions or the fan/blower. 

REV A 9/18/15 

Wiring your Heat Torch 050 

Simply connect the white leads to single phase power at the 
specified voltage.  

Electrical Interlock 

Tutco-Farnam Custom Products strongly recommends the 
use of an electrical interlock with the air source—this helps 
ensure that the heater will not run without air.  