background image

 40

Function 

SMS Command 

Command No.

Add the Watchman 

number bound with all 

sensor(s)

 

#106#

WatchmanNumber

#S*#

 

(16)

Add the Watchman 

number bound with all 

camera(s) and 

sensor(s)

 

#106#

WatchmanNumber

#

 

(17)

Remove a bound 

camera and a sensor 

from a Watchman 

number 

#107#

WatchmanNumber#CameraNumber

#

SensorNumb

er

(18)

 

Remove the bound 

camera(s) and 

sensor(s) from a 

Watchman number 

#107#

WatchmanNumber#CameraNumber

#....

CameraN

umber

#

SensorNumber

#...#

SensorNumber

(19)

 

Remove all bound 

camera(s) and 

sensor(s) from a 

Watchman number 

#107#

WatchmanNumber

# (20)

 

Remove all Watchman 

number(s) 

#107# (21)

Arm the 

device 

manually 

Arm the host

 

#01#

 

(25)

Arm the camera(s)

 

#01#

CameraNumber

#....

CameraNumber

#

 

(26)

 

Arm all camera(s)

 

#01#*#

 

(27)

Timing 

arm/disarm

the device 

Available timing 

arm/disarm all 

camera(s)

 

#128#1#

 

(34)

Available timing 

arm/disarm a camera

 

#128#1#

CameraNumber

#

 

(35)

Set time period to 

arm/disarm all 

camera(s)

 

#129#

WorkDay

#

Period1ArmingTime

#

Period1Disarming

Time#...#Period3ArmingTime

#

Period3DisarmingTime#

 

(36)

Set time period to 

arm/disarm a camera

 

#129#

WorkDay

#

Period1ArmingTime

#

Period1Disarming

Time#...#Period3ArmingTime

#

Period3DisarmingTime#C

ameraNumber

#

 

(37)

Disable timing 

arm/disarm all 

camera(s) 

#128#0# (38)

 

Disable timing 

arm/disarm a camera 

#128#0#

CameraNumber

# (39)

Summary of Contents for D2

Page 1: ...T U TA D 2 G S M R E M O T E C A M E R A USER MANUAL UserManual V1 1 ...

Page 2: ...ghting The TUTA D2 can capture images according a pre programmed remote Short Message Service SMS commands You can also send an SMS command to the device in order to obtain real time images The TUTA D2 is also compatible with up to 4 normal easy to use wired sensors which include wired infrared body door and smoking sensors You can also opt to buy our TUTA D2 already assembled with any of these ab...

Page 3: ...Camera 11 2 9 Capture image 11 2 10 Disarming the device 11 2 11 Host 11 2 12 Indicator Status Instructions of the host 11 2 13 Motion detection 11 2 14 Show alarm on computer 12 2 15 Settings 12 2 16 Timing arms disarms the camera 12 CHAPTER 3 NORMAL OPERATIONS 12 3 1 Power On Off 12 3 2 Starting the device 13 3 3 Change the password 14 3 4 Name the cameras 14 3 5 Sensor 15 3 5 1 Name a sensor 15...

Page 4: ... to arm disarm the camera 27 4 2 3 Disable timing arm disarms the camera 28 4 3 Timing sends MMS images 28 4 3 1 Available timing sends MMS images 29 4 3 2 Set time period to send MMS image 29 4 3 3 Disable timing sends MMS image 30 4 4 Image parameter setting 31 4 4 1 Setting the image size 31 4 4 2 Image quantity when automatic alarm 31 4 5 Motion detection 32 4 6 Change the Super administrator ...

Page 5: ...reless transceiver devices etc Do not throw this product in a fire as this may cause the battery to explode This product should only be operated from 220V 50Hz or 110V 60Hz US AC power sources and DC12V backup storage battery The use of any other types of power sources may damage the product Keep this product and its accessories out of the reach of the children EXCEPTION CLAUSE 1 We operate on a p...

Page 6: ...as required by applicable law we offer no warranties of any kind expressed or implied including but not limited to the accuracy reliability or contents of this document We reserve the right to revise this document or withdraw it at any time without prior notice ...

Page 7: ...trol Control and configure the camera with short messages SMS commands from a mobile phone Double mode alarm The camera can send alarm messages via SMS and MMS Fixed time monitor The monitoring schedule can be set with multiple time intervals Up to ten mobile phone numbers can be set to receive alarm messages Multiple warning phone numbers setting A phone number can be set to receive one or severa...

Page 8: ...ty Remarks 1 TUTA D2 host 1pc 2 GSM antenna 1pc 3 Network cable 1pc 4 cable 6pcs Input output cable for sensor alarm device connecting and camera power supply 5 Management Software CD 1pc 6 User Manual 1pc 7 Installation Guide 1pc 1 3 Host interface ...

Page 9: ... numbers change the password and use all functions of TUTA D2 except receiving alarm information via mobile phone 2 1 2 Administrator numbers The Administrator numbers are set by the Super Administrator number See Chapter 3 6 Add or remove administrator number Administrator numbers have the authority to request images from corresponding camera s and set the device via SMS command 2 1 3 Watchman nu...

Page 10: ...e device manually Arm the device including the host or camera by sending SMS commands or click ARM button on the TUTA WIRELESS IMAGE MONITORING SYSTEM 2 5 Arming the host When the host is armed if the connected camera is armed too the host will send an alarm message via SMS MMS upon sensor alarm or detection of any motion within the monitoring area These alarm messages will be sent to the Watchman...

Page 11: ... at all When a camera is disarmed neither the bound sensor s nor motion detector of the camera will alarm But the sensor which is not bound to the camera will still trigger the armed host sending out an alarm SMS message 2 11 Host The host is the TUTA D2 host 2 12 Indicator Status Instructions of the host Color Action Status Red Flash slowly Device initializing Flash quickly Sensor alarm or motion...

Page 12: ...d the alarm message to authorized user mobile phone according to preset operation procedures 2 15 Settings All the settings can be set or adjusted via SMS commands or TUTA WIRELESS IMAGE MONITORING SYSTEM 2 16 Timing arms disarms the camera If the user sets the timing arming of the camera sucessfully the camera not including the host will change its working mode to armed or disarmed automatically ...

Page 13: ...used for the first time or the device has been reset the Super Administrator number must be programmed into the host in order to ensure proper activation Command The user who will be the Super Administrator user must send the following SMS command to the device in order to Start the device 00 1 Successful SMS reply Welcome Super administrator ID PW 888888 IP Note The information returned in a succ...

Page 14: ...ful SMS reply Change super administrator password to Failed SMS reply If a user other than the master user attempts to change the password a notification message will be sent via SMS stating Sorry you are not authorized to use this command 3 4 Name the cameras Authority Super Administrator number Administrator number can name the cameras which have been bound together with the Administrator number...

Page 15: ...ority Super Administrator number and Administrator number Description After connecting the sensor with the host the user can name the sensor in order to identify which sensor sends out the SMS alarm information The sensor description will be contained in the SMS alarm information Command The user must edit and send the following SMS command to the device in order to Name the sensor 05 SensorNumber...

Page 16: ...the user s Command The user must edit and send the following SMS command to the device in order to Bind a sensor with the camera s 5 40 SensorNumber CameraNumber CameraNumber Bind a sensor with all camera s 6 40 SensorNumber SensorNumber is in the range of S1 to S4 It should be corresponding with the number of Sensor Signal Input on the host SensorNumber can be replaced with SensorDescription Came...

Page 17: ...eraNumber should be a one digit number and in the range of 1 to 4 It is the camera number which is bound with the sensor A sensor can be bound with up to eight cameras CameraNumber can be replaced with CameraDescription Successful SMS reply Remove sensor from camera camera successfully Remove all sensors from binding cameras 3 6 Add or remove administrator number 3 6 1 Add an administrator number ...

Page 18: ...evice will reply Sorry you are not authorized to use this command If ten Administrator numbers are used on the device and the user attempts to add another one the device will reply Administrator numbers list is full Please delete old number 3 6 2 Remove an administrator number Remove bound camera Authority Super Administrator number Description If the user removes a bound camera from the Administr...

Page 19: ...camera from Admin number successfully Failed SMS reply If the Administrator number is invalid the device will send a notification message via SMS stating Invalid phone number please check and try again 3 6 3 Check administrator number Refer to Chapter 4 8 Check status 3 7 Add or remove watchman number 3 7 1 Add an watchman number Authority Super Administrator number Description Up to ten Watchman ...

Page 20: ...aNumber should be a one digit number and in the range of 1 to 4 It should be the camera number which will bind with the WatchmanNumber Replace CameraNumber with means all connected cameras CameraNumber can be replaced with Camera Description SensorNumber is in the range of S1 to S4 It should be the sensor number which will bind with the Watchman number Replace SensorNumber with S means all connect...

Page 21: ...ameraNumber SensorNumber SensorNumber Remove all bound camera s and sensor s from a Watchman number 20 107 WatchmanNumber Remove all Watchman number s 107 21 WatchmanNumber should be the existing mobile number which falls under the Watchman user category CameraNumber should be a one digit number and in the range of 1 to 4 It should be the camera number which bound with the WatchmanNumber Replace C...

Page 22: ...ce in order to Capture an image at a time 03 CameraNumber 22 Capture several images at a time 23 03 ImageQuantity CameraNumber Capture one image per camera at a time 03 24 The ImageQuantity should be set in the range of 1 to 3 CameraNumber should be one digit number and in the range of 1 to 4 It should be the camera number which is to capture an image The default image size is 320 240 QVGA it can ...

Page 23: ...st working on armed mode all cameras working on disarmed mode Command The user must edit and send the following SMS command to the device in order to Arm the host 01 25 Arm the camera s 01 CameraNumber CameraNumber 26 Arm all camera s 01 27 CameraNumber should be one digit number and in the range of 1 to 4 It should be the camera number which is to be armed Replace CameraNumber with means all conn...

Page 24: ...d be the camera number which wants to disarm Replace CameraNumber with means all connected cameras CameraNumber can be replaced with Camera Description Successful SMS reply Disarm the host successfully Disarm the camera successfully Failed SMS reply If the camera number is invalid the device will send a notification message via SMS stating Invalid camera number please check and try again CHAPTER 4...

Page 25: ...parameter 31 145 mode name The mode should be WAP or HTTP The name should be the name of GSM provider such as vodafone For example 145 WAP vodafone Successful SMS reply MMS parameter set WAP HTTP successfully Failed SMS reply If the name does not preset the device the device will send a notification message via SMS stating The operator does not exist please contact the dealer 4 1 2 Setting MMS cen...

Page 26: ...r numbers have authority to timing arm disarm the camera s which are bound with them Description The arm disarm schedule can be set onto the camera s with up to three periods per day The schedule can be reset again and again onto a camera and the last setting will always be activated The function of manual arm disarm the camera is disabled if the camera is under timing arm disarm status When the c...

Page 27: ...eriod to arm disarm all camera s 36 129 WorkDay Period1ArmingTime Period1DisarmingTime Period3Armin gTime Period3DisarmingTime Set time period to arm disarm a camera 37 129 WorkDay Period1ArmingTime Period1DisarmingTime Period3Armin gTime Period3DisarmingTime CameraNumber Up to three periods could be set via this command WorkDay one digit the values lie in the range of 0 to 4 The following table c...

Page 28: ...39 CameraNumber should be one digit number and in the range of 1 to 4 It should be the camera number which wants to disable timing arm disarm CameraNumber can be replaced with Camera Description Successful SMS reply Timing arm disarm the camera disabled Failed SMS reply Failed to disable timing arm disarm the camera 4 3 Timing sends MMS images Authority Super Administrator number has authority to ...

Page 29: ...be one digit number and in the range of 1 to 4 CameraNumber can be replaced with Camera Description Successful SMS reply Timing sends MMS images activated Failed SMS reply Wrong parameter Please check and try again 4 3 2 Set time period to send MMS image Command The user must edit and send the following SMS command to the device in order to Set time period to auto send MMS image for all camera s 4...

Page 30: ...t number and in the range of 1 to 4 It should be the camera number which wants to set timing period CameraNumber can be replaced with Camera Description Successful SMS reply Autosend IMG CAM period to Int to Int to Int Failed SMS reply Wrong parameter Please check and try again 4 3 3 Disable timing sends MMS image Command The user must edit and send the following SMS command to the device in order...

Page 31: ... size is 160 128 pixels the size of one MMS image in this instance is 4K If the value is 2 the image size is 320 240 QVGA default the size of one MMS image in this instance is 9K If the value is 3 the image size is 640 480 VGA the size of one MMS image in this instance is 33K CameraNumber should be one digit number and in the range of 1 to 4 CameraNumber can be replaced with Camera Description Suc...

Page 32: ...umbers have authority to set the camera s which are bound with them Description The motion detection feature only functions when the camera is armed Note If the camera is set up so that it faces an object that moves constantly a tree shaking in the wind it will send alarm message notifications constantly Therefore it is preferable to only use the camera in a still and quiet place Command The user ...

Page 33: ...er will then not be able to control the device anymore Note After changing of Super Administrator number the password will return to default 888888 There is only one Super Administrator number The user can change it via SMS command or via TUTA WIRELESS IMAGE MONITORING SYSTEM 4 7 Reseting the device Authority Super Administrator number Description This function resets all programmed settings to th...

Page 34: ...d Otherwise a notification will be sent stating Resume to default setting command is 08 password and the command will be rejected 4 8 Check status Authority Super Administrator and Administrator numbers Description The user can check the present settings and work status of the device via mobile phone Refer to the actual MMS reply from the device for complete information regarding the status of the...

Page 35: ...d commands 09 55 Successful SMS reply The device will reply with three SMS messages The command description as well as the codes will be supplied Arm 01 Disarm 02 Capture images 03 quantity camNo Change password 04 OldPW NewPW Add Admin numb 06 numb Add Watch numb 106 numb Check status 07 4 9 2 Getting detailed instruction via MMS Command The user must send the following SMS command to the device ...

Page 36: ...use it in the bathroom or other place with high humidity Do not pour water or other liquids into the host Do not store and use the host in dusty areas Do not use alcohol acetone and other similar solvents to clean the device Wipe it with soft damp cloth Do not attempt to open it except as instructed If the device does not work normally try to resolve it as the guide of the general troubleshooting ...

Page 37: ...era CVBS signal is OK Then check the connection of camera signal cable and the host 5 MMS functions disable Network busy or delay Contact with network provider or service MMS functions of the SIM card do not active Contact network provider to active the MMS function 6 All SMS and MMS functions disabled Indicator is work Caller display function and MMS functions of the SIM card do not active insuff...

Page 38: ...y operation Host works abnormally Switch off the host power check SIM card or reset to default setting 5 After starting the camera indicator flashed in red color and can not turn to green Network signal weak or network busy Place the camera at other place with strong signal and try again SIM card PIN code active Close the PIN code SIM card invalid Contact with local operator Note If the problem ca...

Page 39: ...ssword newpassword 2 Change the Super Administrator number 14 NewSuperAdminNumber 52 Admin numbers Add the Administrator number bound with the camera s 06 AdministratorNumber CameraNumber CameraNumber 9 Add the Administrator number bound with all camera s 06 AdministratorNumber 10 Remove the bound camera s from an Administrator number 113 AdministratorNumber CameraNumber CameraNumber 11 Remove an ...

Page 40: ...07 WatchmanNumber 20 Remove all Watchman number s 107 21 Arm the device manually Arm the host 01 25 Arm the camera s 01 CameraNumber CameraNumber 26 Arm all camera s 01 27 Timing arm disarm the device Available timing arm disarm all camera s 128 1 34 Available timing arm disarm a camera 128 1 CameraNumber 35 Set time period to arm disarm all camera s 129 WorkDay Period1ArmingTime Period1Disarming ...

Page 41: ...period to auto send MMS image for all camera s 116 WorkDay Period1StartTime Period1EndTime Period3StartTime Period3EndTime 42 Set time period to auto send MMS image for a camera 116 WorkDay Period1StartTime Period1EndTime Period3StartTime Period3EndTime CameraNumber 43 Disable timing sends MMS image for all camera s 115 0 44 Disable timing sends MMS image for a camera 115 0 CameraNumber 45 Help Ge...

Page 42: ... parameter and center Choose network operator s MMS parameter 145 mode name 31 Setting MMS center 124 MMScenter 32 Setting APN parameters 125 GatewayIP GatewayPort APN APNUserName APNPassword 33 Language Switch to Spanish version 127 0 57 Switch to English version 127 1 58 Reseting Reseting the device 08 PassWord 53 CellTech Alarms a subsidiary of Cell Sign Technologies 324 Ragsdale Rd Manchester ...

Reviews: